LONG TERM STORAGE LV Operation Manual 91 5. Recoil start engines: (a) Push the decompression lever down and hold it while slowly pulling the recoil starter (b) Pull the decompression lever up. Pull the recoil starter slowly and stop when there is 6. Electric start engines: (a) Set the decompression lever at the non- compression position. Do not move the (b) Turn the key to the start position and turn the engine for 2 to 3 seconds. Do not start (c) Pull the decompression lever up. 7. Drain the fuel tank or make sure it is completely full. 8. Protect the air cleaner, muffler and electrical components (dynamo, starter motor, 9. Disconnect the negative (-) battery cable to prevent the battery from discharging. 10. Check the battery fluid and add distilled water as required. 11. Charge the battery once a month during storage. 12. Clean the engine and store it in a dry place. RETURNING THE ENGINE TO 1. Perform the Daily Checks on page 34. 2. Start the engine. Allow the engine to idle, or run without load if there is no idle position in (a) proper oil pressure. (b) fuel, engine oil, or coolant leaks. (c) proper operation of the indicators and / or gauges (if equipped). 3. Avoid prolonged operation at minimum or maximum engine speeds and loads for the |