Fault code No. Designation Meaning Task Related parameter No. 383 AL Wiring TOP 3 Alarm configuration; Short circuit or wire break on tran‐ sistor output, plant-side 3 (TOP 3). Check cabling to plant. 2.8006.64 0 384 AL Wiring TOP 4 Alarm configuration; Short circuit or wire break on tran‐ sistor output, plant-side 4 (TOP 4). Check cabling to plant. 2.8006.64 1 390 AL MCR exceeded Alarm configuration; DBR/ MCR function: MCR has been exceeded. 1. If alarm is only temporary, no ac‐ tion required; tinuously active, contact Service. 1.1085.00 9 392 HI T-Coolant Red Alarm configuration limit value 1; Preliminary warn‐ ing: Redundant coolant temperature reading too high. 1. Check cabling. 2.0129.93 1 393 SS T-Coolant Red Alarm configuration limit value 1; Main warning: Re‐ dundant coolant tempera‐ ture reading too high; en‐ gine shutdown. 1. Check sensor and wiring. 2.0129.93 2 394 LO P-Lube Oil Red Alarm configuration limit value 1; Preliminary warn‐ ing: Redundant lube oil pressure reading too low. 1. Check sensor and wiring. 2.0112.92 1 395 SS P-Lube Oil Red Alarm configuration limit value 2; Main warning: Re‐ dundant lube oil pressure reading too low. 1. Check sensor and wiring. 2.0112.92 2 396 AL T-Coolant Max De‐ viation Alarm configuration; Maxi‐ mum coolant temperature deviation. 1. Check sensor and wiring. 1.8004.62 6 397 AL P-Oil Max Deviation Alarm configuration; Maxi‐ mum lube oil pressure devi‐ ation. 1. Check sensor and wiring. 1.8004.62 5 400 AL Open Load Digital Input 1 Alarm configuration; Line disruption on digital input 1; Cabling faulty or no resist‐ ance over switch. 1. Check cabling. ice.; target device. 2.8006.62 5 401 AL Open Load Digital Input 2 Alarm configuration; Line disruption on digital input 2; Cabling faulty or no resist‐ ance over switch. 1. Check cabling. ice.; Check input of target device. 2.8006.62 6 |