6500 WATT SILENTDIESEL GENERATOR. Manual - part 6

 

  Index      Engines     6500 WATT SILENTDIESEL GENERATOR - service manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  4  5  6  7   ..

 

 

6500 WATT SILENTDIESEL GENERATOR. Manual - part 6

 

 

16

8.1 Replacing the Engine Oil 

1. 

Operate the engine for two to three minutes without allowing the engine 

to get hot. 

2. 

Turn off the engine

3. 

While  the  engine  is  still  swarm,
remove  the  oil  filter  cap  and  the 
drain plug located on the bottom of 
the  cylinder  block,  allowing  the  old 
oil  to  drain.  Insert  the  drain  plug, 
refill  with  recommended  oil  and 
place  the  oil  filter  cap  back  on  the 
engine.  Remember  to  recycle  your 
oil as it is a major cause of soil pollution.

8.2 Cleaning the engine oil filter

Clean the engine oil filter every six months 
or  500  hours,  whichever  comes  first. 
Replace  if  necessary  with  authorized 
All-Power parts.

8.3 Replacing the air cleaner 

Do not clean the air cleaner with detergent. 
Replace  the  unit  every  six  months  or  500 
hours,  whichever  comes  first,  with 
authorized All-Power parts.

Caution:    Never  operate  the  engine 
without the air cleaner or with a defective cleaner as it can damage the interior of 
your engine and shorten its life. 

8.4 Cleaning and replacing the fuel oil filter 

The  fuel  oil  filter  also  requires  periodic  cleaning  to  insure  maximum  engine 
performance. 
Cleaning: Every six months or 500 hours 
Replacement:  Every year or 1000 hours 

17

1. 

Drain all fuel from the fuel tank.

2. 

Remove  the  small  screw  from 
the fuel valve, removing the fuel 
filter from its port.

3. 

Wash  the  filter  thoroughly  with 
diesel fuel. 

4. 

Loosen the fastening nut, bottom 
cover  and  delivery  discs  for 
removing any carbon. 

5. 

Replace the filter and all parts to 
their original position. 

8.5 Tightening the Cylinder Head Bolt 

 Tightening the cylinder head requires a special tool. Do Not attempt this yourself! 
Contact your authorized All-Power service center. 

8.6  Checking  the  injection  nozzle  and  fuel  injection  pump requires 
an

 authorize All-Power Service Center where they will: 

1. 

Adjust the clearance for the intake/exhaust valves. 

2. 

Grind the intake and exhaust valves 

3. 

Replace the piston ring 

Warning: Do not perform the injection nozzle test near an open flame as the fuel 
may  ignite.  Do  not  expose  bare  skin  to  the  fuel  as  it  may  cause  injury. Always
keep away from the nozzle. 

18

8.7 Checking refilling and charging the battery 

Your  diesel  generator  uses  a  12V 
battery  for  starting.  Through  use,  the 
battery  may  naturally  lose  some  of  its 
charge  along  with  the  distilled  water 
inside.  Before  starting  your  generator, 
periodically  check  for  physical  damage 
to the battery and also the fluid levels. If 
the battery is damaged, replace it. If the 
fluid levels are low, fill each cell with distilled water as needed. Never use well or  
tap water as they contain minerals that will harm your battery and shorten its life. 

Warning: 

  Batteries contain sulfuric acid which can burn your eyes and skin. Whenever 

working with a battery, protect your eyes and skin from exposure to the acid. 
In case of contact with  any  acid immediately thoroughly flush the  affected 
area with clean cold water and seek prompt medical attention.

  Batteries also generate hydrogen gas which can be extremely explosive. Do 

not  smoke  or  allow  flames  near  a  battery,  especially  while  in  a  charging 
mode. Always charge batteries in a fully ventilated area. 

8.8  Inspecting  the  carbon  brush  and  slip  ring.

Periodically, check the 

generators carbon brush and slip ring and readjust if there is a spark. 

19

9. Long-Term Storage 

If your plan on storing your generator for 
periods  of  time  exceeding  one  month, 
please follow these guidelines:

1. 

Operate  the  engine  for  two  to 
three minutes. Do  not  allow the 
engine to get hot.

2. 

Turn off the engine 

3. 

While the engine is still warm, drain the crankcase oil by opening the oil 
drain plug. 

4. 

When  all  oil has  drained, replace the  plug and refill the oil reservoir with 
clean oil. 

5. 

Remove  the screw  plug on the cylinder head  and refill   of an  ounce of 
oil (22 CC) and replace the screw plug. 

6. 

It is now necessary to turn the engine over without starting it.

a)  Recoil  Start:  Push  the  decompression  level  down  to  the  non-

compression  position  and  hold  it  while  pulling  the  recoil  starter  three 
times.

b)  Electric  Start:  Turn  the  engine  for  2-3  seconds  with  the 

decompression  lever set  in  the non-compression mode  and the key in 
the “start” position.

7. 

Now pull the decompression lever up and pull the recoil starter slowly until 
you  begin to feel resistance. In this position  both  the intake  and  exhaust 
valves are closed which prevents rust from forming inside the engine. 

8. 

Wipe off any oil or dirt from the engine and store your generator in a dry 
place. 

 

 

 

 

 

 

 

Content   ..  4  5  6  7   ..