6500 WATT SILENTDIESEL GENERATOR. Manual - part 5

 

  Index      Engines     6500 WATT SILENTDIESEL GENERATOR - service manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  3  4  5  6   ..

 

 

6500 WATT SILENTDIESEL GENERATOR. Manual - part 5

 

 

12

Caution 

  Identify and connect positive-to-positive and negative-to-negative poles from, 

the  battery  to  the  engine.  Crossing  the  wires  will  destroy  both  the  battery 
and the electrical components of your generator. 

  If  you  attempt  to  use  a  larger  battery  than  recommended  you  will  create 

excessive current that will blow the fuse in the generator. 
Do  not  attempt  to  operate  the  generator  while  it  is  still  connected  to  the 
battery. 
Do not use a 12V battery and AC current at the same time.  

Caution 

  All  lead  batteries  emit  explosive  gas  when  being  charged.  Keep  sparks, 

flames  and  cigarettes  away  from  the  battery  while  charging.  To  prevent 
sparks, always connect the booster cables to the battery first and then to the 
generator.  When  the  battery  is  charged,  disconnect  the  cables  from  the 
generator first.

  Charge the battery in a well ventilated place.
  Unless  the  battery  is  sealed,  remove  the  caps  from  each  cell  before 

charging. 
Stop charging if the battery feels extremely hot.  If the temperature  exceeds 
45C or 113F then the battery is too hot.

13

6.3  All  electrical  appliances,  particularly  motor  driven  equipment, 
have  extremely  highly  levels  of  current  draw  during  their  start-up 
period.  The  table  below  provides  a  quick  reference  regarding 
connecting different types of devices to the generator. 

14

7. Stopping Your Generator 

Step  I: Disconnect all electrical plugs from the generator outlets before  turning 
off the generator! 
Step II:
 Turn off the “AIR” switch on the generator.

Step  III:  Set  the  speed  level  in  the  “run”  position,  operating  the  generator  for 
about  three  minutes  with  nothing  plugged  in.  Note:  Do  Not  stop  the  generator 
without this step, as the operating temperature of the engine will increase thereby 
damaging the unit. 
Step IV: Depress the “stop” lever 
Step V: If the unit has an electric starter, turn the key to the “off” position. 

1. 

Move the fuel lever to the “S” position. 

Step  VI: Retract the recoil starter  handle  until you  feel resistance.  (At this point 
both the intake and exhaust valves are closed). Leave the handle in the position 
as it prevents damp air from  entering the engine and thereby prevents rust from 
forming. 

Warning:  

  Should the engine continue to operate when the speed lever is placed in 

the  “Stop”  position,  either  turn  the  fuel  valve  to  the  “Close”  position  or 
loosen  the  nut  of  the  high  pressure  fuel  pipe  on  the  pump  side  of  the 
engine.  If  you  do  this,  remember  to  tighten  it  again  before  attempting  to 
start the engine. 
Do not attempt to stop the engine with the decompression lever. 
Always  make  certain  that  all  electrical  plugs  are  removed  from  the 
generator outlets before turning off your generator. 

15

8. Periodic Maintenance and Testing 

Periodic  inspections  and  service  are  very  important  for  maintaining  your 
generator’s  engine  in  proper  working  order.    The  following  chart  indicates  your 
inspection and service frequency. Please keep this chart handy and refer to it as 
needed. 

Warning: 

  Turn off the engine before  performing any service.  If the  engine  must be in 

operation,  only  do  so  in  a  well  ventilated  area  as  the  exhaust  contains 
carbon monoxide which can be fatal.

  After the generator has  been operated, remove all  dirt  and sediments from 

the outside cover to prevent corrosion. 

Note:” ” indicates that special tools are required, please contact with agent. 

 

 

 

 

 

 

 

Content   ..  3  4  5  6   ..