Tsunami2 Digital Sound Decoder. Diesel Manual - part 18

 

  Index      Engines     Tsunami2 Digital Sound Decoder. Diesel Manual 2017 year

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  16  17  18  19   ..

 

 

Tsunami2 Digital Sound Decoder. Diesel Manual - part 18

 

 

Miscellaneous Features 

Tsunami2 Diesel User’s Guide 

 

72 

 
CV 218 (Analog Mode Motor Start Voltage) determines the voltage level applied to start the 
motor in analog mode. Set CV 218 to a value greater than the value of CV 219 to ensure engine 
exhaust sound effects are activated prior to motor start.  
 
Note: Tsunami2 preforms better in analog mode when a higher quality, electronically regulated 
powerpack is used to supply filtered DC power. Using older rheostat-style or pulse powerpacks 
will make operation erratic and should not be used to power Tsunami2-equipped installations in 
analog mode. If your powerpack has a pulse power switch, make sure that it is turned off. 
 

Operating With a CurrentKeeper™  

 
Your Tsunami2 has been designed to operate far more efficiently than previous generations of 
SoundTraxx DSDs giving you more reliable operations over dirty track, isolated frogs or other 
electrical imperfections than ever before. If your model has limited electrical pick-up or you 
desire to add more energy storage to the installation, a SoundTraxx CurrentKeeper can be used 
with any Tsunami2 decoder to provide added reliability. Refer to the Tsunami2 Installation 
Guide 
for more information about how to connect a CurrentKeeper to the various styles of 
decoders. 
 
The CurrentKeeper is designed to work with most decoder installations without the need to 
adjust any CVs. Occasionally, there are a few features and operating scenarios that warrant a 
minimal amount of programming for optimal operation. For more information including how to 
optimize the decoder for use with a CurrentKeeper in analog (DC) mode and how to limit the 
duration of operation of the model 

when it’s being powered by the CurrentKeeper, please refer 

to the 

“CurrentKeeper Reference” found on our website. 

 

 

Miscellaneous Features 

Tsunami2 Diesel User’s Guide 

 

73 

 

Gas Turbine Electric (GTEL) Features & Operation

*

 

 
The sound set for the Gas-Turbine Electric (GTEL), representative of the Union Pacific 
Turbines, has been shipped with all CVs pre-programmed so you can begin using your 
locomotive immediately without having to worry about what adjustments to make. However, the 
software for this sound set is as unique as the prototype, and we have several special features 
to enhance the experience of running your ‘Big Blow’. 
 

Operation Overview 

These locomotives were truly unique and thus require a feature set that is as well! Just like the 
prototype, the sound sets have both a diesel prime mover and a turbine. The diesel prime 
movers found on these locomotives were designed primarily for powering the air compressor, 
radiator fans and hostling the locomotive around the yard, while the turbine supplied the 
horsepower necessary to pull heavy tonnage trains throughout the Union Pacific system. Based 
on extensive research conducted during the development of this feature, the operating 
characteristics of the decoder have been designed to correctly match the operation of the 
prototype turbine locomotives. 
 

Selecting the Prime Mover 

We’ve made prototypical operation of your Turbine 
locomotives easier than ever before! Your decoder features 
pre-configured prime mover options for each of the 4 most 
common types of Union Pacific Turbine locomotives. 
Selecting one of the GTEL specific prime mover sounds 
using CV 123 (Prime Mover Select) automatically enables all features associated with the Gas 
Turbine Electric sound set including proper diesel engine sounds, proper diesel engine 
operation and muting of unused sound effects. 
 
Selecting the “Slab Side” turbine option chooses a Cummins diesel engine. It also allows this 
small hostler engine to shut down once the turbine has been started. 

If you select the “Veranda” 

turbine option, the Cummins diesel engine will continue to run after the turbine has been started.  
 
Selecting one of 

the “Big Blow” prime mover options splits the operation of the diesel engine 

and turbine into two groups

: A unit and ” unit. The A unit contained a Cooper-Bessemer diesel 

engine, air compressor, radiator, dynamic braking and all other controls and appliances. The 
trailing B unit contained only the turbine and a cooling fan. Choosing the A unit will mute the 
turbine sound effects to replicate the operation of the leading control unit. Choosing the B unit 
option will allow only the turbine and brake squeal effects to play, mimicking the trailing unit. 
 
When configuring a matched pair of “Big Blow” locomotives, we recommend installing one 
decoder in each of the A and B units. You can program the decoder addresses (either primary 
or extended) to the same number for each unit to make consisting and operation extremely 
easy. When selecting the prime mover choice, remember to only configure one unit at a time to 
ensure that each unit is programmed correctly.  
 

Operating with the Gas Turbine Electric Features 

Control of both the diesel engine and the turbine can be accomplished in a multitude of ways. 
We’ve divided these into three modes of operation: fully automatic, semi-automatic and manual 
mode.  
 
                                                

*

 Gas Turbine Electric (GTEL) specific features are not supported in software versions 1.1 and older. 

CV 123: Prime Mover Select 

7   = 

“Slab Side” GTEL 

8   = 

“Veranda” GTEL 

9   

= “Big Blow” A unit GTEL 

10 = 

“Big Blow” B unit GTEL 

Miscellaneous Features 

Tsunami2 Diesel User’s Guide 

 

74 

 

Fully Automatic Mode 

This mode is designed to allow for realistic operation of the Gas Turbine Electric locomotives 
with minimal input from the user. By default, this option gives you full control of both prime 
movers (diesel and turbine) as well as realistic speed limiting of the locomotives when operating 
with the turbine shut down. 
 
Upon power up, the decoder will begin to start the diesel hostler engine. Once the engine has 
been started, increasing the throttle will advance the diesel engine to notch 2. Increasing the 
throttle to speed step 8 (when operating in 128 speed step mode) will begin the start sequence 
of the massive gas turbine. Like the prototype, while the gas turbine is starting, the speed of the 
model will be limited to speed step 8.  
 
Once the turbine is operating, the speed of the locomotive will no longer be limited. Increases 
and decreases in throttle will change the turbine RPM level in the same fashion as a 
conventional diesel locomotive.  
 
Upon stopping the locomotive, the turbine RPM level will reduce to idle and the Turbine Timeout 
(CV 3.273) counter will begin. After 128 (default) seconds, the turbine will begin to shut down in 
order to 

“conserve fuel” and “limit noise pollution.” 

 
Pressing the emergency stop key will also shut down the turbine and reduce the diesel engine 
to idle. 
 

Semi-Automatic Mode 

While fully automatic mode allows for realistic operation of the GTEL features, we’ve built in a 
few more options to create more fun for the engineer in charge of these mighty locomotives. 
 
Typically, when these locomotive were moved throughout the rail yard the turbine would remain 
shut down until attached to a train and departure was eminent. To allow for movement at 
speeds greater than speed step 8 (of 128) program CV 3.272 (Turbine Speed Step Limit) to a 
value of 25 or so. 

You’ll also want to turn off the automatic turbine start speed step feature by 

programming CV 3.271 (Turbine Start Speed Step) to a value of 0. This allows the hostler to 
move the GTEL from the roundhouse to the train at a reasonable speed without having to start 
the turbine.  
 
When you’re ready to leave the yard, manually start the turbine using the turbine start/stop 
feature (F16 by default). When the throttle is advanced beyond speed step 0, RPM level of the 
turbine will be regulated based upon the auto-notching rate set in the first 4 bits of CV 114 
(Engine Exhaust Control) like any other diesel locomotive. 
 
Upon completing the journey and arriving at your destination, turn off F16 (default) to shut down 
the turbine. The diesel engine can then be used to move the locomotive to the servicing area. 
 

Manual Mode 

This mode is designed to replicate every aspect the prototypical operation of these unique 
locomotives by disabling all automatic controls of the diesel engine and the turbine. All CV 
changes to enable semi-automatic mode will also apply when configuring manual mode. 
 
To prevent the turbine from shutting down while waiting at a station or in a passing siding, 
disable the turbine timeout feature by programming CV 3.273 (Turbine Timeout) to a value of 0. 
The turbine can now only be manually shut down using the RPM- function (F6 by default) or by 
turning off the turbine start/stop feature (F16 by default). 
 

Miscellaneous Features 

Tsunami2 Diesel User’s Guide 

 

75 

 
In addition, for full control of the prime mover RPM level, disable the auto-notching feature 
controlled by CV 114 (Engine Exhaust control). To accomplish this, set the first 4 bits (bits 0-3) 
to 0. You will now be able to manually increase or decrease the RPM level of the diesel engine 
and turbine by turning on the RPM+ and RPM- functions.  
 
Lastly, to prevent the turbine or the diesel engine from shutting down while the model is moving, 
enable the interlock feature. Turn on the LOCK bit by adding 16 to the current value of CV 114 
(Engine Exhaust Control). 
 

CVs unique to the Gas Turbine Electric Sound Sets 

The following CVs are unique to the Gas Turbine Electric prime mover choices. 
 

Primary Mixer Volume Levels  

Both the prime mover (diesel engine) and the turbine have their own independent volume level 
that can be set to a value between 0 and 255. They are currently defaulted to the following 
levels: 
  
CV 131 Prime Mover = 150 
CV 146 Gas Turbine = 200 
 

Reverb Mixers  

CVs have been provided to control the reverb effect for both the prime mover (diesel engine) 
and the turbine. The default values are set to 0. These CVs are: 
  
CV 163 Prime Mover Reverb Mixer 
CV 168 Gas Turbine Reverb Mixer 
 

Alternate Mixer Volume Levels  

Like the primary mixer volume levels, both the diesel engine and turbine have their own 
independent alternate mixer volume levels that can be set to a value between 0 and 255. They 
are currently defaulted to the following levels: 
  
CV 2.291 Prime Mover = 75 
CV 2.296 Gas Turbine = 100 
 

Prime Mover Pitch Shift 

CV 223 will adjust the pitch and tone of the gas turbine only. It will have no effect on the diesel 
engine.  
 

Turbine Start/Stop Effect 

This effect takes the place of the HEP mode effect (F16 by default) when any of the 4 GTEL 
prime mover choices are selected using CV 123 (Prime Mover Select). When configuring 
function mapping using Flex-Map Function Mapping Technology, refer to the CVs listed below 
to relocate the turbine start/stop effect to any function key on your throttle. 
 
CV 1.303 HEP mode or Turbine Start/Stop Effect Map Register = 16 
CV 1.431 HEP mode or Turbine Start/Stop Auxiliary Effect Map Register = 0 
 
If 

you’re using Legacy Function Mapping (CVs 33-46), the turbine start/stop effect replaces the 

HEP Mode column in the table. Refer to page 60 of this document for a copy of this table.  
 
 

 

 

 

 

 

 

 

Content   ..  16  17  18  19   ..