S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-7 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

Bridge and Highway Metal Component Manufacturers, or equivalent.  The Contractor shall supply 
documentation with the shop drawings. 

26.3.2 

Submittals for Joint Sealing Systems 

This article shall apply to following joint sealing systems: 

1.  Compression seal expansion joints 

2.  Preformed elastomeric neoprene profile seal expansion joints 

3.  Low-density, closed cell, cross-linked, nitrogen-blown seal expansion joints 

As  with  all  bridge  deck  joint  designs,  a  critical  factor  is  accurately  predicting  the  anticipated 
movement. If a compression seal is too big for an opening, it will bulge above 

a deck’s surface and 

become exposed to traffic, which can cause premature wear. If a compression seal is too small for 
an opening, it will lose compression and fall out. 

The Contractor shall provide the Manufacturer of the joint sealing system with a working drawing for 
each installation. Such drawings shall include all of the following information:  

a.  Identification and orientation of each joint  

b.  Length of each joint, including a turn up of at least 150 mm at both barrier faces 

c.  Total projected movement range of each joint  

If  the  Project  involves  the  installation  of  bridge  deck  joints  acros

s the  bridge’s full  width,  working 

drawings shall indicate the use of a full-length seal. If traffic conditions require joint seal installation 
in stages, working drawings shall indicate splice points. 

If existing edge beams are to remain as joint headers, the Contractor shall also give the Manufacturer 
of the seal the following information:  

  Joint width measurements taken at 600 mm intervals along the full length of the joint, plus a 

measurement of the joint width of each barrier in the area of the turn ups  

  Ambient temperature, taken at the same times as the width measurements  

The  Manufacturer  of  the  joint  sealing  system  shall  use  this  information  to  determine  required 
quantities of materials and each joint’s profile size. The Manufacturer shall enter this data on working 
drawings, verify that the data is accurate, and submit a copy to the Engineer for review. Drawings 
from the Contractor shall indicate such verification. The E

ngineer’s approval is required before the 

Contractor installs a joint seal. Such approval shall not relieve the Contractor of any responsibility 
for conforming to specifications and plans. 

26.3.3 

Submittals for Strip Seal Type Expansion Joints 

The strip seal joint Manufacturer shall be prequalified with a five year proven history of successful 
product manufacture and have AISC certification, as defined in their AISC 204-08, or equivalent. 

Before fabricating any joints, the Contractor shall submit shop drawings and expansion joint details 
and  requirements  to  the  Engineer  for  review  and  approval.  Shop  drawings  shall  meet  all 
requirements outlined in this chapter. Before final acceptance of an expansion joint, the Contractor 
shall submit the Manufacturer certifications that verify that the entire expansion joint assembly and 
all its accessories meet the requirements of the Contract plans, specifications, and approved shop 
drawings. 

The Contractor shall provide shop drawings for any proposed joint installation. The Engineer must 
approve  all  shop  drawings,  which  must  indicate  such  approval,  before  installation  of  a  joint.  The 
Engineer  shall  review  the  Contractor's  working  drawings  to  ensure  that  the  Contractor  properly 
interprets  the  Contract  plans.  The  Owner  shall  assume  no  responsibility  for  the  accuracy  of  the 
drawings. The Owner approval for the C

ontractor’s drawings shall not relieve the Contractor of any 

responsibility for conformity to specifications and Contract plans. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-8 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

Shop drawings that the Contractor submits for review and approval by the Engineer shall specifically 
include the following items: 

a.  The 

Manufacturer’s brochures related to the proposed joint. Such brochures shall include all 

physical  dimensions for components,  installation  procedures,  material  certifications,  and  a 
table of variable temperatures and dimensions. 

b.  Drawings  that  detail  installation  of  the  joint.  Such  drawings  shall  indicate  lengths  of 

component members, treatments for any directional changes, shop splices for steel channels 
(gland components shall not be spliced in the field), and the fabrication of metal components 
at barriers, curbs, and parapets. 

As with compression seal designs, movement ratings must be correctly anticipated. Openings, as 
measured along the centreline of the bridge, should not exceed the preferred maximum of 100 mm. 
This limitation improves the ride, reduces live load impact, and reduces danger to motorcyclists and 
bicyclists. For sealing element installations, the Owner prefers joint opening dimensions of 50 mm. 

The  Engineer  may  require  the  Contractor  to  furnish  whatever  samples  are  needed  to  perform 
specified materials qualification tests. The Engineer shall provide written acceptance of any joint to 
be used in the Project work. 

Joint movements and construction material temperatures are vital to designing expansion joints. The 
joint’s complete expansion-contraction cycle must be known before selecting the proper system and 
Manufacturer. 

26.3.4 

Submittals for Finger Type Expansion Joints 

The  Contractor  shall  submit  to  the  Engineer  shop  drawings  prepared  by  the  joint  manufacturer 
showing the finger size and spacing and configuration of the assembly which shall satisfy the skew 
alignment  and  expansion  requirements for  each  joint  as  indicated  on the  Contract  plans.  Special 
considerations shall be taken in providing the proper precautions to ensure the water-tightness of 
this type of joints. 

26.3.5 

Submittals for Elastomeric Expansion Joints 

The  Contractor  shall  submit  a  certification  by  the  Manufacturer,  stating  that  the  joint  and  the 
accessory items meet the requirements of these standard specifications. The Engineer will request 
the Contractor to furnish whatever samples may be required to perform the tests specified to qualify 
the material. Acceptance of the elastomeric expansion joint to be used in the Project shall be subject 
to  written  approval  of the  Engineer.  Special  considerations shall  be taken  in  providing  the  proper 
precautions to ensure the water-tightness of this type of joints. 

26.3.6 

Submittals for Modular Bridge Joint System 

The Contractor shall submit details of any modular bridge joint system (MBJS) to the  Engineer for 
approval  before  the  Contractor  fabricates  an  MBJS. With  these  details,  the  Contractor  shall  also 
submit installation and waterproofing shop drawings. At a minimum, shop drawings shall include the 
following details: 

a.  Plan and section views of the MBJS for each movement rating and roadway width, showing 

dimensions and tolerances 

b.  All welded centerbeam (support) bar joints, with all shop and field splices, only full strength 

welds meeting the strict requirements of fatigue shall be acceptable 

c.  Complete details of all components and sections, with all material incorporated into the MBJS 

d.  All ASTM, AASHTO, or other material designations 

e.  A corrosion protection system for the MJS 

f.  Lifting locations and lifting mechanisms (as parts of an integral installation plan) 

g.  Temperature adjustment devices and opening dimensions relative to temperature 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-9 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

The Contractor shall also submit the following test reports and certificates to the Engineer for review 
and approval: 

1.  The 

Manufacturer’s certificate of compliance with the AISC’s quality certification program for 

simple steel bridges. 

2.  Certification  that  welding  inspection  personnel  are  qualified  and  certified  as  welding 

inspectors in accordance with the American Welding 

Society’s 

Standard for Certification of 

Welding Inspectors

 (AWS QC1). 

3.  Documentation that any personnel performing nondestructive evaluation (NDE) are certified 

by the American Society for Nondestructive Testing (ASNT). 

4.  The M

anufacturer’s certificate of compliance for polytetrafluoroethylene (PTFE) sheeting and 

fabric. 

5.  Certification that the MBJS passed prequalification tests (as outlined in Section 26.4.7)

6.  Certification  that  bearings,  springs,  and  equidistant  devices  are  the  same  formulation, 

Manufacturer, and configuration as those used in prequalification tests, as required in Section 
26.4.7.  Each  certification  shall  provide  the  name  and  address  of  the  Manufacturer  of  the 
springs, bearings, and equidistant devices.  

7.  Design calculations  sealed  by  a registered  professional  engineer. The  design  calculations 

shall include a fatigue design and a load factor design for all structural elements, connections, 
and splices. 

8.  Plan for replacement of parts that are subject to wear, as allowed for in the design.  

9.  A written maintenance and part replacement plan prepared by the joint

’s Manufacturer. This 

plan shall include a list of parts and instructions for maintenance inspection, acceptable wear 
tolerances, methods for determining wear, and procedures for replacing worn parts. 

10. Method of installation that, at a minimum, includes a sequence, installation gap settings for 

various  temperatures,  support  methods  during  placement  of  the  concrete,  and  details  for 
installation at curbs. 

11. Recommendations for storage of the MBJS. 

12. Details for temporary support when shipping and handling the joint. 

13. Welding procedure specifications. 

14. Any required changes to the blockout reinforcement to accommodate the MBJS. 

15. Temporary  bridging  plan  for  any  MBJS  for  which  construction  traffic  is  anticipated  after 

installation. 

26.3.7 

Submittals for Fixed Joint Seals 

The  Contractor  shall  submit  a  certification  by  the  Manufacturer,  stating  that  the  joint  and  the 
accessory items meet the requirements of these standard specifications. The Engineer will request 
the Contractor to furnish whatever samples may be required to perform the tests specified to qualify 
the material. Acceptance of the fixed joint seal to be used in the Project shall be subject to written 
approval of the Engineer. 

26.3.8 

Submittals for Asphaltic Plug Type Joint 

The Contractor shall submit details of previous projects within the U.A.E. These should demonstrate 
the  suitability  of  the  system  and  materials  proposed,  in  particular,  for  heavy  traffic  and  high 
temperature. 

The supplier shall provide the Engineer with the following information, in a printed form, for each APJ 
system: 

1.  Description or proprietary name of joint 

2.  Horizontal movement capacity 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-10 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

3.  Vertical movement capacity 

4.  Composition 

– aggregate, binder, bridging plate, caulking, and flashing. 

26.4 

Materials for Bridge Deck Joint Systems 

Unless  the  Contract  documents  specify  otherwise,  the  Contractor  shall  use  one  of  the  following 
systems of expansion joints as approved by the Engineer: 

1.  Compression seal expansion joints 

2.  Preformed elastomeric neoprene profile seal expansion joints 

3.  Low-density, closed cell, cross-linked, nitrogen-blown seal expansion joints 

4.  Strip seal type expansion joints 

5.  Finger type expansion joints 

6.  Elastomeric expansion Joints 

7.  Modular bridge joint system 

Materials for bridge deck joint systems shall meet the requirements outlined in this section. 

26.4.1 

Compression Seal Expansion Joints 

In general, bridge deck compression  seal expansion joint  materials shall conform to the following 
specifications: 

a.  Preformed elastomeric joint seals of multiple web design shall conform to AASHTO M 220-

84 (2012), (ASTM D2628 - 91(2011)). 

b.  Lubricant-adhesive for use with preformed elastomeric seals shall conform to ASTM D4070 

- 08. 

c.  Deck  joint  seal  assemblies  shall  be  of  an  approved  type  for  each  size  required  and  shall 

conform to the specifications provided by the Manufacturer at the time of approval. 

d.  All  Steel  and  fabricated  steel  components  shall  be  galvanised  and  conform  to  the 

requirements outlined in Section 23.4.10 of Chapter 23, Steel Structures. 

26.4.2 

Preformed Elastomeric Neoprene Profile Seal Expansion Joints 

At a minimum, a preformed elastomeric neoprene profile seal shall meet the following requirements:  

a.  Capability to be evacuated of air during installation  

b.  Capability to be pressurized with air during the adhesive curing time  

c.  Compatibility with the epoxy adhesive, and header material (if required)  

d.  Ability to withstand 50% expansion and 50% contraction (total 100%)  

e.  Ability  to  withstand  the  effects  of  vertical  and  lateral  movements,  skew  movements,  and 

rotational movements without adhesive or cohesive failure 

The Contractor shall ensure that preformed elastomeric neoprene profile meets the requirements of 
ASTM D2628 - 91(2011) and that the adhesive used with preformed elastomeric neoprene profile 
seals  is  a  two-component  epoxy-

based  thixotropic  paste  that  meets  the  seal  manufacturer’s 

requirements. 

26.4.3 

Low-density, Closed Cell, Cross-Linked, Nitrogen-blown Seal Expansion Joints 

At  a  minimum,  a  low-density,  closed  cell,  cross-linked,  ethylene  vinyl  acetate,  polyethylene 
copolymer, nitrogen-blown seal shall meet the following requirements:  

a.  Held in place by a two-component, 100% solid, modified epoxy adhesive 

b.  Compatibility with the epoxy adhesive, and header materials (if required) 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-11 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

c.  Preformed, resistant to abrasion, oxidation, oils, gasoline, salt, and other materials that may 

be spilled on or applied to the surface 

d.  Grooved, with grooves approximately 3 mm wide by 3 mm deep, spaced from 6 mm to 13 

mm apart, and running along the entire length of the seal’s bonded surface 

e.  Designed so that, when compressed to 50% of original width, the centre portion of its top 

does not extend upward above the seal’s original height by more than 6 mm  

f.  Recessed below the riding surface throughout the normal limits of joint movement  

g.  Resistant to ultra violet rays  

h.  Beige or gray 

i.  Shop-marked such that the top and bottom are clearly visible during installation  

The  Contractor  shall  ensure  that  a  low-density,  closed  cell,  cross-linked,  ethylene  vinyl  acetate, 
polyethylene  copolymer,  nitrogen-blown  seal  has  a  working  range  of  30%  tension  and  60% 
compression. Such seals shall have physical properties that comply with the details shown in Table 
26-2.
 

Table 26-2: Physical properties for low-density, closed cell, cross-linked, ethylene vinyl 

acetate, polyethylene copolymer, nitrogen-blown seal

 

Test 

Requirements 

Test method 

Tensile strength 

0.80 MPa 

ASTM D3575 - 08  
(Suffix T) 

Elongation at break 

255% min. 

ASTM D3575 - 08  
(Suffix T) 

Weather-related 
deterioration 

No deterioration for at least 10 years 

AASHTO T 42-10 
(Accelerated Weathering) 

Compression/Set 

0.069 MPa min., 0.414 MPa maximum @ 
50% deflection of original thickness 

ASTM D3575 - 08  
(Suffix D) 

Tear strength 

20 kN/m 

ASTM D624 - 00(2012) 

Density 

45 to 54 kg/m

3

 

ASTM D3575 - 08 

Low-density,  closed  cell,  cross-linked,  ethylene  vinyl  acetate,  polyethylene  copolymer,  nitrogen-
blown  seals  shall  use  a  two-component,  100%  solid,  modified  epoxy  adhesive  that  meets  the 
requirements of ASTM C881 / C881M - 10, Grade 2, Class C. Such adhesives shall have physical 
properties as shown in Table 26-3. 

Table 26-3: Physical properties for the adhesive used with the low-density, closed cell, 

cross-linked, ethylene vinyl acetate, polyethylene copolymer, nitrogen-blown seals

 

ASTM 

Value 

Tensile strength 

ASTM C881 / C881M - 10 

24 MPa (minimum) 

Compressive strength 

ASTM D695 - 10 

48 MPa (minimum) 

Shore D hardness 

ASTM D2240 - 05(2010) 

75 

Water absorption 

ASTM D570 - 98(2010)e1 

0.25% by weight 

Bond strength 

ASTM C882 / C882M - 12 

2.97 MPa 

For applications on moist or hard to dry concrete surfaces, an adhesive shall be as specified by the 
joint material’s Manufacturer. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-12 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

26.4.4 

Strip Seal Type Expansion Joints 

Each bridge deck strip seal joint, shall have a continuous elastomeric strip seal gland with extruded 
steel channels. Such glands shall be a vulcanized elastomeric compound that uses only polymerized 
chloroprene as its basic elastomer.  

The  Contractor  shall  provide  to  the  Engineer  certified  test  results  from  the  strip  seal 

gland’s 

Manufacturer that verify that the gland has the properties shown in Table 26-4.  

Table 26-4: Physical properties of the strip seal gland

 

Physical property 

ASTM test method 

Requirements 

Tensile strength (minimum) 

ASTM D412 - 06ae2 

13.8 MPa 

Elongation @ break % (minimum) 

ASTM D412 - 06ae2 

250 % 

Hardness, Type A durometer, points 

ASTM D2240 - 05(2010) 
(Modified) 

55 ± 5 points 

Oven aging, 70h @ 100° C: 
Tensile strength loss 
Elongation loss 
Hardness (Type A durometer) 

ASTM D573 - 04(2010) 

 
20% maximum 
20% maximum 
0 to +10 change in 
points 

Oil swell, ASTM oil no. 3, 70h @ 100° C, 
maximum weight change 

ASTM D471 - 12 

45% 

Ozone resistance, 20% strain, 300 pphm in 
air 70h @ 40°C 

ASTM D1149 - 07(2012) 
(Modified) 

no cracks 

Low temperature stiffening, 7 days @ -10° C: 
Hardness (Type A durometer) 

ASTM D2240 - 05(2010) 

0 to +15 change in 
points 

Compression Set, 70h @ 100° C maximum 

ASTM D395 - 03(2008) 
Method B 
(Modified) 

40% 

Steel channels shall be extruded in one piece from grade 50W (Grade 345 W) steel that complies 
with ASTM A588 / A588M - 10. Such elements shall not be exposed aluminium.  

A lubricant or adhesive shall bond a seal to steel elements. Such lubricant or adhesive shall be a 
one-part moisture curing polyurethane and hydrocarbon solvent mixture that meets the requirements 
of ASTM D4070 - 08. 

Studs in an anchorage system shall meet the requirements outlined in Section 30.5 of Chapter 30, 
Miscellaneous Metal. Straps that the Contractor uses to erect the bridge deck joint sealing system 
shall be grade 36 (Grade 250) steel as defined in ASTM A588 / A588M - 10. 

All steel surfaces not embedded in concrete shall be treated for corrosion protection in accordance 
with  the  Manufacturer’s  recommendations.  Backer  rod  shall  be  placed  in  the  steel  anchoring 
element’s’ seal cavity if painting is required. 

26.4.5 

Finger Type Expansion Joints 

Each joint element shall be anchored to the concrete with galvanized high strength bolts. The finger 
joint assembly shall be drained by installation of a 2-layer-thick hypalon-neoprene membrane placed 
at the base of the joint and across the expansion gap as indicated on the Contract plans. Materials 
used in the manufacture of the finger type expansion joints shall comply with the requirements of 
ASTM A307-10 and ASTM A588 / A588M - 10. In general, the materials incorporated in the finger 
type expansion joint shall comply with the following: 

Drainage  Collector: 

A  hypalon-neoprene  double  layer  sheet  (European  commercial  name 

Coverlight TH4 26/26) having the following characteristics: 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-13 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

Weight  

 

 

 

 

 

0.600 kg/m² 

 

Thickness 

 

 

 

 

 

5.5 to 6.0 mm  

Tensile strength (on a 5 x 20 cm specimen)   

330 kg 

Tear strength   

 

 

 

 

28 kg 

Compression resistance (Nullen test) 

 

5.4 MPa 

Hypalon  is  a  commercial  name  for  chlorosulphonated  polyethylene  (CSM),  Neoprene  is  a 
commercial name for chloroprene (CR). 

Steel: 

All steel components shall comply with ASTM A588 / A588M - 10. 

Bolts, Washers and Accessories: 

Class 8.8 complying with American National Standard Institute 

ANSI  B18.2.1-1981,  Square  and  Hex  Bolts  and  Screws,  Including  Askew  Head  Bolts,  Hex  Cap 
Screws and Lag Screws. 

Corrosion Protection

: Zinc metal spraying thickness 102 microns. 

Coupling Sleeve:

 American Iron and Steel Institute (AISI) Type 410. 

26.4.6 

Elastomeric Expansion Joints 

The elastomeric expansion joints shall consist of integrally molded units of neoprene and bonded 
steel components so arranged as to provide for the expansion and contraction movements of the 
bridge deck with one of the steel components bridging the joint gap and of sufficient strength to carry 
wheel loads across the joint. 

The expansion joints shall seal the deck surface to prevent moisture and other contaminants from 
descending onto the abutment and pier caps and shall have provisions for adequate anchoring of 
the joint assembly to the bridge deck. There shall be no appreciable change in the deck surface with 
the bridge expansion and contraction movements. All the expansion and contraction movements of 
the bridge deck shall be taken entirely by deformation of the neoprene. 

The  elastomer  portion  of  the  expansion  joints  shall  be  neoprene  having  the  following  physical 
properties as determined by the following ASTM requirements shown in Table 26-5: 

Table 26-5: Physical properties of the neoprene for elastomeric expansion joints

 

Property 

ASTM Test 
Method 

Performance 
Requirements 

Tensile Strength 

ASTM D412 - 
06ae2 

12.3 MPa minimum 

Elongation at break 

ASTM D412 - 
06ae2 

400%, minimum 

Hardness, Type A Durometer 

ASTM D2240 - 
05(2010) 

50 ± 5 points, 

Compression Set 22 hours at 70°C 

ASTM D395 - 
03(2008) 
(Method B) 
 

20%, maximum 
 

Low Temperature 

ASTM D746 - 07 

Not brittle at -40°C 

Ozone Resistance 
Exposure to 100 pphm ozone for 70 hours @ 
38°C sample under 20% strain 

ASTM D1149 - 
07(2012) 

No failure cracks 

Oil Deterioration 
Volume increase after immersion in ASTM Oil #3 
for 70 hours @ 100°C 

ASTM D471 - 12 

120%, maximum 

The dimensional tolerances of the neoprene portion of the elastomeric joint shall be minus zero mm 
to plus 6 mm for the width and length, and minus zero mm to plus 3 mm for the thickness of the 
exterior dimensions required on the Contract plans measured at 21°C. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-14 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

The sealant for sealing joints between the expansion joint units, along the edges of the expansion 
joint, and the bolts and plugs shall be a high solids, one-part polyurethane based sealant that cures 
quickly, without shrinkage, into a rubber with high elongation characteristics and excellent "memory." 
The sealant shall be capable of bonding to concrete, steel, and neoprene without the use of a primer. 
When cured, the sealant shall possess excellent abrasion resistance and shall resist attack by salt, 
oil, and road chemicals. The sealant to be used shall meet with the approval of the manufacturer of 
the neoprene expansion joint. 

When test specimens are cut from the finished product a 10 percent variation in "Physical Properties" 
may be allowed by the Engineer. 

The  flexible  epoxy  for  filling  void  space  around  the  nut  fasteners  shall  consist  of  a  black  two 
component flexible epoxy sealant having the following physical properties as shown in Table 26-6: 

Table 26-6: Physical properties of black two component flexible epoxy sealant

 

Base Material 

Flexibilized Epoxy Resin 

Color 

Black 

Weight/Liter (Mixed materials) 

1.05 kgs./liter 

Mixing Time 

2 min. @ 24°C with 50 strokes minimum 

Pot Life 

10-15 minutes @ 24°C 

Initial Cure 

4 hours @ 24°C 

Final Cure 

48 hours @ 24°C 

Shelf Life 

12 months minimum (components separate) 

Hardness Shore A Durometer 

80 ± 10 

The flexible epoxy shall be supplied either in cans or preassembled cartridges. Flexible epoxy shall 
meet with the approval of the manufacturer of the expansion joint. Flexible epoxy must also be a 
material compatible with and having the physical characteristic, when cured, similar to the neoprene 
of the joint.  

The adhesive/sealant bedding epoxy for bonding the expansion joint to concrete or steel shall be 
supplied in premeasured cartridges or cans and shall consist of a grey, two component flexible epoxy 
having the following physical properties as shown in Table 26-7: 

Table 26-7: Physical properties of grey two component flexible epoxy

 

Base Material 

Epoxy Resin 

Color 

Concrete Grey 

Weight/Liter (Mixed Materials) 

1.44 kgs./liter 

Solids Content 

98% minimum by weight 

Mixing Time 

2 min. @ 24°C with 50 strokes minimum 

Pot Life 

25-30 minutes @ 24°C 

Initial Cure 

4 hours @ 24°C 

Final Cure 

48 hours @ 24°C 

Shelf Life 

12 months minimum (components separate) 

Tensile Strength 

20.6 MPa 

Elongation 

7% @ 24°C 

Water Absorption 

1.0% maximum 

Bond Strength to Concrete 

Concrete fails before bond 

All  structural steel for  use  in  elastomeric  expansion  joints  as  detailed  on the  Contract  plans  shall 
comply with the requirements of ASTM A1011 / A1011M - 12b or ASTM A36 / A36M - 08. 

Structural steel angles and anchors shall be fabricated and hot dip galvanized in accordance with 
the requirements of ASTM A123 / A123M 

– 12 and Section 23.4.10 of Chapter 23, Steel Structures, 

of these Standard Specifications. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-15 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

a.  Anchor Bolts 

Anchor bolts for joint seals shall be hot dip galvanized in accordance with ASTM A153 / A153M - 09, 
commercial grade bolts set in epoxy mortar in holes cored in the deck in accordance with approved 
shop drawings. 

Surfaces of holes cored in the concrete shall be carefully prepared to provide a cleaned, textured 
surface to which the epoxy mortar can successfully bond. Faces shall be mechanically tooled until 
surface glaze and contamination have been removed; dusted to remove all residue; dried thoroughly; 
and then primed with hydrophobic epoxy resin immediately prior to setting the anchor bolts in epoxy 
mortar. Bolts shall be degreased with white spirit alcohol and dried thoroughly. Coring and setting of 
anchor bolts shall not be done until a minimum of 7 days after concrete is poured. 

b.  Epoxy Mortar 

Epoxy mortar shall consist of a mixture of aggregate and epoxy binder. Aggregate shall consist of 
well graded, clean, hard quartzite particles of 2 mm maximum size. Aggregate shall be dried till the 
moisture content is less than 0.2 percent by weight and then shall be sealed in plastic containers 
until required for mixing on site. Binder for epoxy mortar shall be two part, cold curing, solventless 
epoxy resin supplied by an approved Manufacturer. Primer shall be compatible with the epoxy resin 
binder  and  shall  be  supplied  by  the  same  Manufacturer.  The  type  of  resin  selected  shall  be 
recommended  by  the  Manufacturer  for  this  application  and  shall  meet  with  the  approval  of  the 
supplier of the component on which it is to be used. 

Components of the epoxies shall be proportioned, mixed, applied and cured strictly in accordance 
with  the  Manufacturer's  printed  recommendations.  Mixing  shall  be  carried  out  in  an  efficient 
mechanical device which ensures that all components are fully dispersed and wetted. The two parts 
of the epoxy binder for the mortar shall be thoroughly mixed first without frothing and the aggregate 
added progressively. Mixed epoxy mortar which has begun to cure before it has been placed and 
compacted shall be rejected and a fresh batch mixed. 

Anchor bolts shall not be set in epoxy mortar when the ambient temperature is less than 10 degrees 
Celsius. Concrete surfaces shall be primed. Bolts shall be coated with epoxy mortar and assembled 
in such a way as to avoid trapping air bubbles in the mortar. Epoxy mortar shall be compacted around 
the  anchor  bolts and  trowelled  level  with  the  concrete  surface. The  anchor  bolts shall  be  located 
using a template and securely held in place until the epoxy mortar has cured. 

26.4.7 

Modular Bridge Joint Systems 

Materials for a modular bridge joint system (MBJS) shall conform to the following specifications: 

a.  MBJS shall conform to the specifications provided by its Manufacturer. 

b.  MBJS shall be prequalified by satisfying all of the testing requirements detailed in Appendix 

A19 in Section 19 of the 

AASHTO LRFD Bridge Construction Specifications

, which validate 

the use of an approved MBJS for a limited range of applications. 

c.  MBJS designs shall comply with 

Article 14.5, “Bridge Joints,” of the 

AASHTO LRFD Bridge 

Design Specifications

d.  Preformed elastomeric joint seals of multiple-web design shall conform to AASHTO M 297-

10 (ASTM D3542 - 08). 

e.  Preformed elastomeric joint seals of the strip type shall conform to ASTM D5973 - 97(2007). 

f.  Seals  shall  be  continuous;  seals  shall  not  include  splices  unless  such  are  specifically 

approved by the Engineer. 

g.  Lubricant-adhesive for use with preformed elastomeric seals shall conform to ASTM D4070 

- 08. 

h.  Springs, bearings, and equidistant devices (sometimes referred to as 

control springs

) shall 

have the same material composition, formulation, and configuration as control springs used 
in  prequalification  tests.  Their  Manufacturer  and  fabrication  procedure  shall  also  match 
control springs used in such test. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-16 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

i.  Urethane foam shall conform to ASTM D3574 - 11. 

j.  Polytetrafluorethylene  (PTFE)  shall  be  100-percent  virgin  Teflon,  woven  PTFE  fabric,  or 

dimpled  PTFE  that  conforms  to  the  requirements  for  PTFE  sliding  surfaces  outlined  in 
Section 25.4.11 of Chapter 25, Bearing Devices. Every sliding surface shall be PTFE. 

k.  Sliding surfaces shall have type 304 stainless steel sheets as defined in ASTM A240 / A240M 

- 12. In severe environments, such sheets shall be type 316 steel as defined in ASTM A240 
/ A240M - 12.  

l.  Steel and fabricated steel components for members that are not fracture-critical shall conform 

to the applicable requirements of Chapter 23, Steel Structures, with the following exceptions: 

  Welding shall conform to the requirements of ANSI/AWS D1.1/D1.1M:2010 

Structural 

Welding Code-Steel,

 

  Fasteners  and  their  holes  can  deviate  from  the  requirements  in  Chapter  23,  Steel 

Structures, if they were used in the prequalification tests. 

m.  The  Contractor  shall  furnish  manufacturing  certificate  to  the  Engineer  stating  that  the 

materials have been sampled, tested and inspected in  accordance with this specifications 
and have met the requirements. 

26.4.8 

Fixed Joint Seal 

The joint sealer shall be of a neoprene, preformed or extruded type, of essentially the size and shape 
indicated  on  the  Contract  plans.  The  preformed  joint  sealer  material  shall  comply  with  the 
requirements of AASHTO M 220-84 (2012) (ASTM D2628-91 (2011)). The joint sealer shall be such 
that it will repel the intrusion of stones, dirt, etc., into the joint or into the material itself. Lubricant 
adhesive for use with preformed sealer shall conform to ASTM D4070 

– 08. 

All structural steel for use in the fixed joint shall comply with the requirements of ASTM A36 / A36M 
- 08, and as specified in Chapter 23, Steel Structures, for fabrication and welding. All structural steel 
assemblies  shall  be  hot  dip  galvanized  in  accordance  with  ASTM  A123  /  A123M 

–  12  and  with 

Section 23.4.10 of Chapter 23, Steel Structures. 

26.4.9 

Asphaltic Plug Joint (APJ) 

Material, testing and application requirements for field molded asphaltic plug joints (APJs) used in 
expansion  joint  sealing  on  asphalt  concrete  overlay  and  portland  cement  concrete  decks  shall 
comply  with  the  requirements  of  ASTM  D6297 

–  13.  The  asphaltic  binder  to  be  used  shall  be  a 

thermoplastic polymeric-modified asphalt or hot laid elastomer modified bitumen bound material. The 
aggregates shall be crushed, washed, and dried. Physical properties of the asphalt such as softening 
point, tensile adhesion, ductility, resilience, and flexibility shall also be tested and shall conform to 
ASTM D36 / D36M 

– 12, ASTM D113 – 07, ASTM D5 / D5M – 13, and ASTM D217 - 10. 

Rubber bitumen sealant shall comprise a hot applied sealant composed of bitumen, rubber extender 
and filler conforming to the requirements of ASTM D6690 

– 12, ASTM D5167 – 13, ASTM D5249 – 

10, and ASTM D5329 

– 09. 

The Contractor shall propose and submit for the Engineer’s review and approval practical means of 
testing the watertightness aspects of the individual systems, either in the field or at approved testing 
laboratory.  

26.4.10 

Header Materials 

The Contractor shall use elastomeric concrete or epoxy concrete for header material where indicated 
in  the  Contract  plans  or  specified  in  the  particular  specifications.  Otherwise,  the  usage  of  these 
materials shall be strictly in accordance with the direction of the Engineer for the intended application. 

Mixes and uses of elastomeric and epoxy concrete materials shall be in accordance with this section 
and in compliance with the Manufacturers’ guidelines.  

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-17 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

By consulting the most reliable forecasts, the Contractor shall ensure that ambient temperatures will 
fall between 7º C and 38º C throughout the installation of elastomeric concrete material, and will not 
be less 13º C during the installation of epoxy concrete material. 

The  Contractor  shall  not  permit  traffic  to  drive  over  sealed  joints  until  the  header  material  has 
hardened  enough  to  prevent  deck  movement  and  other  vibrations  from  displacing  the  seal. 
Elastomeric concrete shall cool and solidify for at least one hour before a bridge roadway is open for 
traffic. Epoxy concrete shall cure for at least two hours before a bridge roadway is open for traffic. 

26.4.10.1 

Elastomeric Concrete 

a.  Elastomeric Concrete Material 

Elastomeric  concrete  material  includes  two-component  elastomer  and  prebagged  fillers.  The 
Contractor  shall  mix  elastomeric  concrete  material  and  use  it  according  to  its  Manufacturer’s 
recommendations. For such mixing and use, the Contractor may need to apply heat to accelerate 
curing and to ensure a quality bond between concrete and steel. Elastomeric concrete shall have 
the following features: 

1.  Compatibility with all allowable joint seal materials and with all concrete or steel to which it is 

bonded 

2.  Provision of a smooth riding surface across the joint  

3.  Capability of being mixed by normal equipment 

4.  Capability of being mixed and placed when temperatures range from 7º C to 38º C  

b.  Elastomeric Concrete Cured Binder Material 

The  Contractor  shall  ensure  elastomeric  concrete  cured  binder  material  (without  filler)  has  the 
physical properties shown in Table 26-8.  

Table 26-8: Physical properties for elastomeric concrete cured binder material (without 

filler)

 

Test 

Requirements  Test method 

Before oven aging: 

Tensile strength (minimum) 

5.2 MPa 

ASTM D638 - 10 

Elongation at break (minimum) 

200% 

ASTM D638 - 10 

Hardness (Type D durometer) 

39 - 58 

ASTM D2240 - 05(2010) 

Compression set, 22 hrs at maximum 70° 

80% 

ASTM D395 - 03(2008) Method 

Tear resistance (minimum) 

2.7 kg/mm 

ASTM D624 - 00(2012) 
50 mm/min 

Water absorption (maximum) 

1.2% 

ASTM D570 - 98(2010)e1 

Heat shrinkage (maximum) 

1.6% 

ASTM D1299-55(1979)E01 

Impact strength (minimum) 

9.5 N m 

Article d of Subsection 26.4.10.1 

Properties after oven aging at 70° C for 72 hours 

Tensile strength (minimum) 

10.34 MPa 

ASTM D638 - 10 

Elongation at break (minimum) 

200% 

ASTM D638 - 10 

Hardness (Type D durometer) 

90, ± 3 

ASTM D2240 - 05(2010) 

Impact strength (minimum) 

9.5 N m 

Sub-article d of Article 26.4.10.1 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-18 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

c.  Elastomeric Concrete Binder Material 

The Contractor shall ensure that the elastomeric concrete binder material (with filler) has the physical 
requirements shown in Table 26-9.  

Table 26-9: Physical requirements for elastomeric concrete binder material (with filler)

 

Test 

Requirements  Test method 

Resilience at 5% deflection (minimum) 

70% 

Sub-article d of  Article 26.4.10.1 

Bond strength to concrete (minimum*) 

2.6 MPa 

Sub-article d of Article 26.4.10.1 

Wet bond strength to concrete (minimum*) 

1.7 MPa 

Sub-article d of Article 26.4.10.1 

Pot life (minimum) 

5 minutes 

Sub-article d of Article 26.4.10.1 

*greater than concrete failure strength (tensile strength) 

d.  Testing Method for Elastomeric Concrete 

The Contractor shall use this test method to determine pot life, bond strength to concrete, wet bond 
strength to concrete, resilience at 5 percent deflection, and impact strength of elastomeric concrete 
material covered under Article 26.4.10.1 of these Specifications. 

1.  Apparatus 

The apparatus shall consist of the following:  

i.  Containers:  Use  containers  big  enough  to  weigh  each  component  to  the  proper  ratio. 

Also, use a container big enough to hold all components during mixing.  

ii.  Paper Cups: Use unwaxed paper cups, 480 ml, 75 mm diameter base.  

iii.  Wooden Tongue Depressors  

iv.  Large Spoon or Spatula  

v.  Balance: Use a balance capable of weighing the components; accurate to 1 g.  

vi.  Stopwatch: Use a watch with one-second divisions.  

vii.  Molds: Use briquet molds as specified in AASHTO T 132:1987 (R2013).  

viii.  Riehle  Briquet  Tester:  Use  the  tester  or  equivalent  that  meets  the  requirements  of 

AASHTO T 132:1987 (R2013).  

ix.  Saw: Use a diamond-tooth saw or other cutting tool capable of producing clean, smooth 

faces.  

x.  Testing Machine: Use the machine specified in ASTM D638 - 10, equipped with a drive 

mechanism to allow a testing speed of 5 mm/min.  

xi.  Molds: Use cylinder molds (75 x 150 mm)  

xii.  Steel Ball: Use a 414 g ± 23 g steel ball.  

2.   Sample Size and Preparation  

i.  Prior to testing, condition the components to a room temperature of 24

o

C ± 2

o

 C.  

ii.  After conditioning, stir each component to redisperse any settled material. Be careful not 

to contaminate one component with the other.  

3.   Procedures  

I. 

Pot Life (with filler)  

i.  Use the proper size containers to measure each component in proper ratio.  

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-19 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

ii.  Follow the manufacturer's recommendation, if applicable, to add the resin and catalyst 

to be mixed before adding the fillers.  

iii.  Mix  the  components  together  with  a  large  spoon  or  a  spatula  in  the  large  mixing 

container.  

iv.  Start the timer as soon as the resin and catalyst are combined.  

v.  Ensure  that  all  measured  material  is  added  and  that  the  components  are  mixed 

thoroughly.  

vi.  Weigh out 100 g of the mixed material into a 480 ml cup. Place the material in the bottom 

of the cup so that the 100 g will be one mass.  

vii.  Place the sample on a wooden surface that is free of excessive drafts.  

viii.  Use  a  wooden  tongue  depressor  to  occasionally  probe  and  lightly  stir  the  material  to 

determine  the  pot  life.  The  time  it  takes  the  material  to  become  unworkable  will  be 
considered the pot life.  

II. 

Bond Strength to Concrete (with filler)  

i.  Prepare cement mortar briquets according to AASHTO T 132:1987 (R2013). Use Type 

I or III cement meeting the requirements of AASHTO M 85-12, and 20-30 standard sand 
meeting the requirements of ASTM C190-85.  

ii.  Allow the briquets to cure for at least 7 days.  

iii.  Saw the briquets in half at the centerline perpendicular to the long axis.  

iv.  Abrasive blast the cut faces lightly and blow clean with compressed air.  

v.  Place  three  briquet  halves  back  in  the  molds  and  cast  elastomeric  concrete  into  the 

remaining mold spaces. This creates specimens that are half mortar and half elastomeric 
concrete.  

vi.  Cure  the  specimens  for  7  days  at  24

o

C  ±  2

o

  C,  in  50  percent,  ±  10  percent  relative 

humidity.  

vii.  After the required curing time, tensile-load the specimens in the briquet tester at a loading 

rate of 2669, ± 110 N/minute.  

viii.  Report the average bond strength to concrete obtained on the specimens.  

III. 

Wet Bond Strength to Concrete (with filler)  

i.  Prepare the specimens in accordance with Procedures, Step II, i through vi.  

ii.  After the required curing time, submerge the specimens in water at 24

o

C ± 2

o

 C for 7 

days.  

iii.  At the end of 7 days, remove the specimens from the water and immediately tensile-load 

them in the briquet tester at a loading rate of 2669, ± 110 N/minute.  

iv.  Report the average wet bond to concrete obtained on the specimens.  

IV. 

Resilience at 5 Percent Deflection (with filler)  

i.  Mix  enough  material  according  to  the manufacturer's  instructions  to  make  three,  75 x 

150 mm cylinders.  

ii.  Make  the  cylinders  in  three  layers  and  rod  them  25  times  per  layer.  Trowel  the  tops 

smooth.  

iii.  Cure the cylinders 7 days at 24

o

C ± 2

o

 C, in 50 percent, ± 10 percent relative humidity.  

iv.  At the end of 7 days, remove the cylinders from the molds. Make sure the ends of the 

cylinders are relatively perpendicular to the axis. If not, square them with a saw.  

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-20 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

v.  Make four measurements at the quarter points around the circumference of the cylinders. 

Measure to the nearest 0.025 mm the height of the cylinders. Mark these points on the 
side of the cylinders.  

vi.  Determine the average height of each cylinder.  

vii.  Compression-load  the  cylinder  at  5  mm/minute,  to  95  percent  of  its  original  height. 

Measure deflection with a micrometer to the nearest 0.025 mm.  

viii.  Remove the load and let recover for 5 minutes.  

ix.  Measure the average height again to the nearest 0.025 mm, using the same measuring 

points from Procedures, Step IV. v.  

x.  Calculate resilience after 5 percent deflection as follows:  

% Resilience =

Height after recovery  −  Compressed height 

Deflection

 x 100

 

Equation 26-1: Resilience after 5 percent deflection 

V. 

Impact Strength (without filler)  

i.  Cast six specimens with diameters of 69 mm, ± 6 mm and thicknesses of 10, ± 0.6 mm.  

ii.  Allow the specimens to cure for  7 days at  24

C ± 2

o

 C and 50 percent, ± 10 percent 

relative humidity.  

iii.  Mill the cured specimens plane on both faces to the required thickness.  

iv.  Place three of the specimens in a freezer at (- 18

C) for at least 30 minutes.  

v.  Remove  the  specimens  one  at  the  time  from  the  freezer.  Place  them  on  a  smooth 

concrete slab, on a smooth steel plate at least 13 mm thick.  

vi.  Drop a 4.45 kg steel ball onto the center of each specimen from an initial height of 2.1 

m. Perform the drop within 10 seconds of removing the specimen from the freezer. Two 
out of three specimens shall pass using the following criteria:  

  If the specimen shatters or cracks, it fails.  

  If the specimen does not shatter or crack, it passes.  

vii.  R

eport the final results as either “less than 9.5 metre-N” or “greater than 9.5 metre-N”  

viii.  Age the remaining three specimens in the oven at 70

C ± 2

o

 C for 72 hours.  

ix.  Test the specimens according to Procedures, Step V, iv through vii.  

26.4.10.2 

Epoxy Concrete 

In accordance with the Contract plans, epoxy concrete material shall meet the following minimum 
requirements:  

  Compatibility with all allowable joint seal materials and with all concrete or steel to which it is 

bonded 

  Able to provide a smooth riding surface across a joint  

  Able to be mixed using normal equipment  

  Able to be mixed and placed when temperatures are 13º C or higher.  

The Contractor shall use header material that is a two-component rapid curing epoxy with aggregate 
that cures to a dense semi-flexible, weather, abrasion, and impact-resistant epoxy concrete. Such 
material shall have the physical properties shown in Table 26-10.  

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-21 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

Table 26-10: Physical properties of epoxy concrete material 

 

Test 

Requirements 

Test method 

Mixed epoxy without aggregate (before and after oven aging at 70° C for 72 hours) 

Tensile strength (minimum) 

10.0 MPa 

ASTM D638 - 10 

Elongation at break (minimum) 

40% 

ASTM D638 - 10 

Shore D hardness 

45-75 

ASTM D2240 - 05(2010) 

Pot life (maximum) 

45 minutes 

Sub-article d of Article 26.4.10.1 

Mixed epoxy with aggregate 

Compressive strength at 24 hours 
(minimum) 

75 MPa 

ASTM C39 / C39M - 12 (76 mm 
cylinders) 

Resilience at 5% deflection (minimum) 

75% 

Sub-article d of Article 26.4.10.1 

Bond strength to concrete (minimum*) 

34 MPa 

Sub-article d of Article 26.4.10.1 

Wet bond strength to concrete 
(minimum*) 

1.7 MPa 

Sub-article d of Article 26.4.10.1 

Thermal compatibility 

No 
delamination 

ASTM C884 / C884M - 98(2010) 

**greater than concrete failure strength (tensile strength) 

The qualified Manufacturer shall furnish the aggregate used in epoxy concrete. The Contractor shall 
use  well-graded,  clean,  and  dry  aggregate  that  meets  the  gradation  requirement  shown  in  Table 
26-11.
 Care shall be taken to avoid air entrapment upon placement of epoxy concrete around anchor 
bolts. 

Table 26-11: Gradation requirement for aggregate used in epoxy concrete

 

Size 

Percent passing by weight 

No. 4 Sieve 

100% 

No. 80 Sieve 

0-5% 

Note: Test according to AASHTO T 27-11 

a.  Temporary Joint Filler 

The Contractor shall use temporary joint filler when using epoxy concrete material. Temporary joint 
filler shall be an extruded rigid cellular  polystyrene with enough compressive strength to maintain 
correct joint widths and to obtain relatively smooth and straight faces upon removal of the material. 

26.5 

Manufacturing and Fabrication of Bridge Deck Joint Systems 

The Contractor shall have a joint fabricated 

to match a bridge deck’s full width, unless construction 

is staged (one lane at a time) or when joint lengths prohibit shipment. 

26.5.1 

Manufacturing Joint Sealing Systems 

Compression Seal Expansion Joints: 

The Contractor shall not splice preformed elastomeric joint 

seals in the field, unless the Engineer specifically permits such splicing. 

Expansion joint assemblies shall be fabricated by their Manufacturers and delivered to  the bridge 
site completely assembled, unless the Contract documents specify otherwise. 

Preformed Elastomeric Neoprene Profile Seal Expansion Joints: 

The Contractor shall have the 

joint fabricated full width of the bridge deck, except in stage construction (one lane at a time) or when 
joint length prohibits shipment. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-22 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

Low-Density,  Closed  Cell,  Cross-linked,  Nitrogen-blown  Seal  Expansion  Joints: 

The 

Contractor shall have the joint fabricated full width of the bridge deck, except in stage construction 
(one lane at a time) or when joint length prohibits shipment. 

26.5.2 

Manufacturing Strip Seal Type Expansion Joints 

The  seal  gland  shall  be  fabricated  in  one  continuous  strip.  The  Contractor  shall  not  splice  gland 
material in the field.  

The Owner shall not permit welding pieces together in any manner to obtain the final shape of steel 
channels. When directional changes is required, the Owner may permit shop welding for this purpose 
only  using  a  complete  penetration  weld  within  the  steel  channels  in  accordance  with  the 
Manufacturer’s recommendations.  

The geometry of the steel channels shall not allow the accumulation of water and moisture. 

26.5.3 

Manufacturing Finger Type Expansion Joints 

The finger type expansion joint units shall be shop fabricated as indicated on the Contract plans, as 
specified herein and approved by the Engineer on the shop drawings. All metal surfaces shall be 
given the corrosion protection after welding and prior to bolting the assembly together. 

The adequacy of the joint design and installation details shall meet with the approval of the Engineer. 

All welding shall comply with the requirements of Sections 23.4.11 and 23.6.10 of Chapter 23, Steel 
Structures, of these Standard Specifications. The surface of the finished joint shall have an applied 
welded pattern or other textured non-skid surface approved by the Engineer. 

The complete unit shall be fabricated with a minimum of joints and splices. All joints and splices shall 
be subject to approval of the Engineer. Joints and splices shall be designed by the Manufacturer to 
prevent movement or displacement between abutting sections. 

The drainage collector shall have adequate slope of at least 8% to ensure that sand accumulation 
in the collector is washed away during rain storms. 

26.5.4 

Manufacturing Elastomeric Expansion Joints 

The  size  selection  of  elastomeric  expansion  joints  is  predicated  on  movement  of  the  concrete 
superstructures due to shrinkage and creep of concrete and temperature change. 

26.5.5 

Manufacturing Modular Bridge Joint Systems 

A  modular  bridge  joint  system  (MBJS)  shall  be  fabricated  in  accordance  with  the  dimensions, 
shapes,  details,  material  specifications,  and  procedures  shown  in  approved  shop  drawings.  Fillet 
welds shall be welded continuously. An MBJS shall not have intermittent fillet welds. 

The  Contractor  shall  avoid  field  splices  if  at  all  possible.  An  entire  MBJS  shall  be  shipped  and 
installed as one unit. If field splicing cannot be avoided, the Owner recommends that such splices 
be located away from potential wheel paths  or under the median traffic barrier. For an MBJS, the 
Contractor  shall use only field-splice details that have been fatigue-tested in accordance with the 
prequalification tests outlined in Section 26.4.7. Typically, fatigue design will dictate that the span of 
a  centrebeam  with the  splice  must  be  smaller  than  the  continuous  spans; generally,  the  smallest 
span possible works best. 

A full-penetration field weld can sometimes be made from a deck when there is only one centrebeam 
and  it  can  be  lifted  out enough  to  access  the  bottom  of  the  centrebeam. The  Contractor  shall  be 
careful to prevent weld metal from getting into seal retainer grooves, which can lead to seal pullout 
and leaking. The Contractor shall not use fillet or partial penetration welds. If there is more than one 
centrebeam, the Contractor shall not use welded splices. The Contractor may use field splices for 
edgebeam profiles, but only when fillet welds cross only part of the profile. 

The Contractor shall provide lifting devices. In addition, at least three devices along each segment 
of the length of an MBJS shall be provided to maintain the preset opening of a joint; such devices 
shall have uniform spacing that does not exceed 4.5 metres.  

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-23 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

When the fabrication is completed, the Manufacturer shall perform the pre-installation inspection as 
described in Article 26.6.2.426.6.7.2 to ensure that the MBJS passes inspection. 

26.5.5.1 Edgebeam Profile and Anchorage 

The edgebeams shall be fabricated from structural steel. The web of the edgebeam cross section 
shall be at least 9.5mm in thickness. The same cross section used in the prequalification test shall 
be used. Shop splices in the edgebeam profile shall be two sided, complete joint penetration groove 
welds. The edgebeam shall be continuously fillet welded to the support boxes. 

Anchorage  shall  comply  with  Article  14.5.6.9

,  “Modular  Bridge  Joint  Systems  (MBJS),”  of  the 

AASHTO LRFD Bridge Design Specifications

. If an edgebeam cross-section includes a horizontal 

element, such element shall also be anchored to resist the full force of the wheel-load and upward 
impact (from rebound). 

26.5.5.2 Centerbeam and Support Bar 

Centrebeams,  support  bars,  and  connection  details  shall  be  the  same  type  as  those  used  in 
prequalification  tests.  Shop  splices  in  a  centrebeam

’s  profile  shall  be  two-sided,  complete-joint-

penetration  groove  welds.  In  a  welded  multiple  support  bar  MBJS,  a  weld  joint  between  the 
centrebeam and support bar shall be a full-penetration groove weld. 

After welding, the Contractor shall place the centrebeam (support) bar assembly on a flat surface 
and verify that the support bars lie in a single plane, with no part of the bottom of any support bars 
more than 6.5 mm off the surface. The Contractor may make as many as three attempts to heat-
straighten the subassembly.  

26.5.5.3 Seals 

The  seal  Manufacturer  shall  install  seals  in  an  MBJS  before  shipment,  unless  its  centrebeam 
requires field splices. In such cases, the Contractor shall install continuous seals (without splices) in 
the field after construction is complete. In either case, seal installers shall use the same lubricant-
adhesive  that  was  used  in  prequalification  tests.  Seals  shall  extend  out  from  the  ends  of  the 
edgebeams and centrebeams by at least 50mm. 

26.5.5.4 Support Boxes 

To construct support boxes, the Manufacturer shall continuously weld steel plates or tubes that are 
at least 9.5 mm thick. If support boxes are more than 400 mm wide, the thickness of the top plate 
shall  increase  so  that  the  width-to-thickness  ratio  does  not  exceed  45;  otherwise,  the  Contractor 
must apply stiffening. If the Contractor assembles a support box from nested tubes, the diameter or 
width-to-thickness ratio of each tube shall not exceed 45. 

26.5.5.5 PTFE Sliding Surface 

PTFE for sliding surfaces shall be bonded under controlled conditions and in accordance with the 
instructions of either the PTFE Manufacturer or the adhesive Manufacturer. After installers complete 
the bonding operation, a PTFE surface shall be smooth and free from underlying bubbles. 

26.5.5.6 Stainless Steel Sliding Surfaces  

The C

ontractor shall polish an MBJS’s stainless steel surfaces to an 0.20 µm mirror finish. 

26.5.5.7 Corrosion Protection 

All 

of  an  MBJS’s  steel  surfaces,  except  surfaces  under  stainless  steel  or  those  to  be  bonded  to 

PTFE, shall be protected against corrosion. 

Anchors and exposed sections shall be hot dip galvanized in accordance with ASTM A123 / A123M 
- 12. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-24 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

26.5.6 

Manufacturing Fixed Joint Seal 

The sealer shall be so shaped that when installed, at minimum joint opening, it shall be so completely 
compressed as to be substantially solid and have a minimum of air spaces. It shall also be so shaped 
that in its compressed condition the top center of the exposed surface shall be depressed below the 
surface of the sealer edges. The sealer shall be furnished in a sufficient width to accomplish this kind 
of closure. The shape to be used and the width and depth to be furnished shall have prior approval 
of the Engineer. It shall be flexible and pliable and retain its elasticity at temperatures from 54 to -
28

o

 C and shall not develop appreciable permanent set after full compression of the approved joint 

shape for the full effective life of the material. It shall be compatible with the material of which the 
joint surfaces are composed and be relatively unaffected by the normal moisture in the material. The 
joint sealer shall not be field spliced except when specifically permitted by the Engineer. 

Each lot of the joint filler shall be identified with the Manufacturer's name or trade mark and shall be 
accompanied by the Manufacturer's certification attesting compliance with this specification. 

Each  lot  of  the  adhesive  shall  be  delivered  in  containers  plainly  marked  with  the  Manufacturer's 
certification attesting compliance with this specification. 

26.5.7 

Manufacturing Asphaltic Plug Type Joint 

Asphaltic plug joints shall provide a homogenous expansion medium and smooth running surface. 

26.6 

Construction of Bridge Deck Joint Systems 

All  joint  materials  and  assemblies,  when  stored  at  a  job  site,  shall  be  protected  from  damage. 
Assemblies  shall  be  supported to maintain their true shape  and  alignment.  Deck joint  seals shall 
provide a smooth ride. Bridge deck joints shall be covered by protective material after installation 
until final cleanup of the bridge deck. 

After  installation  and  before  final  acceptance,  the  Contractor  shall  test  deck  joint  seals  in  the 
presence of the Engineer for leakage. Any leakage of the joint seal shall be a cause for rejection. 

26.6.1 

Construction of Compression Seal Expansion Joints 

Joints in 

a bridge deck’s roadway areas that are to be sealed with compression seals shall be cast 

to a narrower width than required for the preformed material. Such joints in curbs and sidewalks may 
be cast to full width. Before installation of compression seals in joints that are narrower than needed, 
the Contractor shall saw cut a groove of proper width and depth to receive the preformed material 
along the top of the joint. 

When making saw cuts into a bridge deck, the Contractor shall minimise spalling. Both sides of a 
groove  shall  be  cut  simultaneously  to  the  proper  depth  and  alignment  as  shown  in  the  Contract 
documents. A rigid guide shall control a s

aw’s alignment at all times. A groove’s width shall depend 

on the temperature and age of the concrete and shall comply with directions from the Engineer. Lip 
of  saw  cut  should  be  bevelled  to  avoid  later  breakage.  After  saw  cutting,  any  spalls,  popouts,  or 
cracks shall be repaired before installation of a lubricant sealant. Saw cuts are not required where a 
bridge deck joint includes armour plates. 

During installation, a joint shall be clean, dry, and free from spalls and irregularities that might impair 
a proper joint seal. Concrete and metal surfaces shall be clean and free of rust, laitance, oils, dirt, 
dust, or other deleterious materials. Using suitable hand methods or machine tools, the Contractor 
shall install premoulded elastomeric compression joint seals without damaging them. The Contractor 
shall apply lubricant adhesive to both faces of a joint before installation and in accordance with the 
Manufacturer's  instructions.  Preformed  elastomeric  seal  shall  be  compressed  to  the  thickness 
specified in the Contract documents or in accordance with directions from the Engineer in a manner 
that  is appropriate for  the  rated  opening  and  ambient  temperature  at  the  time  of  installation.  The 
Owner shall not permit loose-fitting or open points between a seal and a bridge deck. 

Construction  of  expansion  joint  seal  assemblies  shall  provide  absolute  freedom  of  movement 
through the range shown in the Contract documents or as prescribed by the Engineer. Final settings 
of  a  deck joint  seal  assembly  at  the  time  of casting  in the  anchorages  of  the  unit  depend  on  the 
relationship  between  the  current  temperature  of  the  superstructure  and  its  expected  mean 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-25 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

temperature. Final settings shall comply with the Contract documents, direction from the Engineer, 
or the recommendations of the deck joint seal assembly’s Manufacturer.  

26.6.2 

Construction of Preformed Elastomeric Neoprene Profile Seal Expansion Joints 

26.6.2.1 Preparing Surfaces 

The  Contractor  shall  ensure  that  compressed  air  used  to  sandblast  and  to  blow  debris  is  free  of 
moisture  and  oil.  For  cleaning  joints,  the  Contractor  shall  use  air  compressors  that  have  suitable 
traps for removing surplus water and oil from the compressed air. The Contractor shall check the 
compressed  air  daily  for  contamination  and  shall  not  use  contaminated  air.  The  compressor  for 
preparation of a bridge deck seal assembly’s surface shall be able to deliver compressed air at a 
continuous pressure of at least 0.620 MPa.  

26.6.2.2 Preparing Headers 

Where  indicated  in  the  Contract  plans  or  specified  in  the  particular  specifications,  the  Contractor 
shall 

prepare  the  headers  in  accordance  with  the  joint  manufacturer’s  recommendations  and  the 

following: 

1.  Remove loose, eroded, and unsound concrete from the surface within the joint area. 

2.  Provide horizontal bonding areas by cutting all angular areas of concrete blockouts.  

3.  Immediately  before  placing  the  header  material,  sandblast  the  concrete  surfaces  or 

abrade free of oil, dust, dirt, traces of asphaltic concrete, or other contaminants.  

26.6.2.3 Preparing to Seal Joints 

To make preparations to seal joints, the Contractor shall do the following: 

1.  Remove loose, eroded, and unsound concrete from the surface within the joint area. 

2.  Immediately before placing the seal, sandblast the concrete surfaces or abrade free of 

oil, dust, dirt, traces of asphaltic concrete, or other contaminants.  

3.  As necessary, saw-cut the concrete deck to provide an acceptable attachment surface 

for the joint seal. 

26.6.2.4 Installing Expansion Joint Seal Assembly 

Installation  of  the  expansion  joint  seal  assembly  shall  comply  with  the  Manufacturer's 
recommendations. The Contractor shall use an installer who has been trained by the Manufacturer 
to install the bridge deck joint sealing system. The Manufacturer’s representative shall be present 
during  the  installation  of  the  approved  header  material  if  any

.  In  addition  to  the  Manufacturer’s 

recommendations, the Contractor shall comply with the specifications in this section. 

26.6.2.5 Blockouts  

Blockouts shall comply with relevant details of the Contract plans. 

26.6.2.6 Weather Limitations 

The Contractor shall not perform any part of an installation in rainy weather or when rain is expected 
within  one  hour  of  an  instal

lation,  and  shall  ensure  that  an  assembly’s  surface  is  completely  dry 

before applying adhesive or  primer. Ambient temperature shall not be less than 13º C during the 
installation of preformed elastomeric neoprene profile seal.  

26.6.2.7 General Safety, Handling, Mixing, Finishing, and Curing 

While complying with the instructions of the joint system’s Manufacturer, the Contractor shall adhere 
to the following procedure to handle, place, finish, and cure the system.  

a.  Fill the blockout, as shown in the Contract Plans, to the correct grade.  

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-26 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

b. 

After filling the blockouts on both sides, cure the material according to the Manufacturer’s 
instructions.  

c. 

Mix and place the epoxy mortar according to the Manufacturer’s recommendations and as 
follows:  

1.  Before  adding  the  aggregate,  thoroughly  mix  the  two  components  (resin  and 

hardener) of the epoxy mortar.  

2.  Mix the epoxy mortar in a mechanical mortar mixer by combining one volume of mixed 

epoxy  (resin  plus  hardener  in  the  required  proportions)  with  three  volumes  of 
aggregate, meeting the requirements of these specifications.  

3.  Prime  the  surface  of  the  concrete  in  accordance  with  the  manufacture's 

recommendations before applying the epoxy concrete.  

4.  Place and finish the epoxy concrete within one half hour of mixing.  

Cure  times  for  epoxy  mortar  are  directly  related  to  temperature.  Table  26-12  provides  general 
guidelines for cure times at various temperatures. 

Table 26-12: Cure time for epoxy mortar

 

Air and Deck Temperature 

Approximate Cure Time 

o

5 hours 

10 

o

4 hours 

16 

o

3 hours 

21 

o

2.5 hours 

27 

o

1.5 hours 

32 

o

1 hours 

38 

o

0.75 hours 

The Contractor shall postpone the installation process if the ambient temperature is 13º C and rising. 
If the Contractor cannot postpone the operation, they shall use supplemental heat to complete the 
operation and reopen the lane in a reasonable time. When using supplemental heat, the Contractor 
shall ensure that curing has prog

ressed throughout a header’s mass. 

26.6.2.8 Mixing and Placing Elastomeric Concrete Material 

The Contractor shall handle, place, finish, and cure the elastomeric concrete material according to 
the Manufacturer’s instructions, and shall allow the elastomeric concrete to cool and solidify for at 
least one hour before opening to traffic. 

26.6.2.9 Preformed Elastomeric Neoprene Profile Joint Seal Application  

The Contractor shall do the following to seal joints: 

1.  After the header material has developed enough strength to be ready for traffic, remove the 

temporary joint filler (when called for) and thoroughly clean the joint faces of all joint filler.  

2.  Lightly sandblast the joint to remove all residue.  

3.  Apply the adhesive according 

to the Manufacturer’s recommendations.  

4.  Install the preformed elastomeric neoprene profile seal so that it is recessed approximately 6 

mm below the riding surface.  

5.  After sealing a joint, promptly remove all surplus residue on the bridge deck.  

26.6.2.10 

Acceptance of Joint Seal Assemblies 

The  Contractor  shall  provide  evidence  from  the  joint  seal  assembly’s  Manufacturer  that  the  joint 
system has been used successfully in installations with similar environmental and project conditions. 
The Owner shall reject a joint seal assembly that fails to perform adequately in actual use.  

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-27 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

26.6.2.11 

Correction of Defects in Joint Seal Assemblies 

At no expense to the Owner, the Contractor shall either repair or remove and replace any completed 
joint seals that leak, have adhesive or cohesive failure, or have damage before final acceptance. 

26.6.3 

Construction  of  Low-density,  Closed  Cell,  Cross-linked,  Nitrogen-blown  Seal 
Expansion Joints 

The construction of Low-density, closed cell, cross-linked, nitrogen-blown seal expansion joints shall 
conform to the requirements of Section 26.6.2.  

By  consulting  the  most  reliable  forecasts,  the  Contractor  shall  ensure  that  ambient  and  surface 
temperatures will remain between 7º C and 24º C throughout the installation of a low-density, closed-
cell, cross-linked, ethylene vinyl acetate, polyethylene copolymer, nitrogen blown seal. 

26.6.3.1 

Low-density, Closed-cell, Cross-linked, Nitrogen-blown Seal Application  

The Contractor shall do the following to complete joint seals: 

1.  After the header material (if required) has developed enough strength to be ready for traffic, 

remove the temporary joint filler (when called for) and thoroughly clean the joint faces of all 
joint filler.  

2.  Lightly sandblast the joint to remove all residue.  

3.  Apply the epoxy adhesive to both sides of the joint opening and into the grooves of the joint 

seal material.  

4.  Splice the seal using the heat welding method, placing the joint seal material ends against a 

Teflon heating iron of 177° C for 7 to 10 seconds and pressing the ends together tightly.  

5.  Install the joint seal material in one piece.  

6.  Begin  installation 

at  the  joint’s  low  end.  Install  the  joint  seal  material  by  compressing  the 

material and pushing it down into the joint opening until it has recessed approximately 6 mm 
below the deck surface. Do not push the joint seal material into the joint at an angle that will 
stretch the seal material.  

7.  After starting to install the joint seal material, do not stop until installation is done.  

8.  Immediately and thoroughly clean off excess epoxy from the surface of the joint material. Do 

not use solvents to clean the top surface of the joint seal material.  

26.6.4 

Construction of Strip Seal Expansion Joints 

Strip seal expansion joints shall seal a deck

’s surface to prevent moisture and other contaminants 

from descending onto pier and abutment caps. Strip joints shall securely anchor the joint assembly 
to  the  bridge  deck,  preventing  any  appreciable  changes  in  the  deck  surface  caused  by  bridge 
expansion and contraction. Deformation of the 

joint’s elastomeric gland shall take all of the bridge 

deck’s expansion and contraction movements. 

The Contractor shall obtain installation instructions from the supplier of the strip seal expansion joint 
material and comply with specified procedures to install such joints. The Engineer shall approve the 
design and installation procedure for any strip seal expansion joints before the Contractor installs 
them. When the Contractor installs the strip seal expansion joint, a field representative 

for the joint’s 

Manufacturer  shall  be  on  hand  to  provide  technical  assistance.  During  joint  installation,  the 
Contractor shall make proper adjustments, as indicated on the Contract drawings, for temperature. 

Installation of strip seal type expansion joint assemblies shall comply with the Contract plans. After 
paving the bridge deck, the Contractor shall make saw cuts across the asphaltic pavement for an 
approved side headers (if required) and break out the asphaltic concrete between these cuts. After 
removing  a  strip  of  asphaltic  pavement  from  between  saw  cuts,  the  Contractor  shall  prevent 
construction traffic from crossing the joint until installation of headers is complete. 

The elastomeric strip seal

’s gland may be installed in the field. The Contractor shall mechanically 

lock the gland component into place. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-28 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

The strip seal joint shall conform to the finished grade of the bridge deck. Its elastomeric component 
shall be recessed sufficiently from the finished grade of the bridge deck under all combinations of 
motion  and  skew  angles  to  prevent  protrusion  above  the  deck  when  the  joint  is  closed.  The 
Contractor shall consider the effects of horizontal curvature, vertical curvature, and skew angles to 
properly size and install a joint. 

Installed joints shall be watertight. 

The Contractor shall not start any work or install any joint seals for the Project until a trained factory 
representative is on the job site to provide direction and assistance throughout the installation work. 
The Contractor shall notify the joint Manufacturer of the scheduled installation at least two weeks in 
advance. This factory representative shall be present for the installation of the first joint seal and any 
number of succeeding joint seals until they are satisfied that the Contractor is proficient in this work. 

Curb-parapet sections of strip seals or sealing systems shall be pre-engineered and approved by 
the Engineer. 

The Contractor shall warn all personnel against breathing adhesive and solvent vapours. They shall 
also warn personnel to avoid letting such adhesive and solvent contact their skin or eyes. Application 
of adhesive and solvents shall take place only in well-ventilated areas. The Contractor shall keep all 
adhesives and solvents away from heat, sparks, and open flames. The Contractor shall follow all the 
Manufacturer's  safety  precautions  as  shown  on  container  labels.  Misplaced  adhesive  shall  be 
immediately removed and seals shall be cleaned of all foreign matter. 

26.6.5 

Construction of Finger Type Expansion Joint 

The Contractor shall obtain installation instructions from the supplier  of the finger type expansion 
joint and shall comply with the procedures specified in the installation of the joint. The Contractor 
shall obtain the technical assistance of a field representative from the Manufacturer of the joint during 
its  installation.  Proper  adjustment  shall  be  made  for  temperature  at  the  time  of  installation  as 
indicated on the Contract plans. 

The superstructure shall be in place and all post-tensioning shall be completed before the installation 
of the finger type expansion joint. Further, the joint  shall be installed before the installation of the 
asphaltic concrete wearing surface. 

Finger  type joint  assemblies  shall  be  installed  in  concrete  blockouts  as  indicated  on the  Contract 
plans  and  as  approved  by  the  Engineer.  All  assemblies  shall  be  set  in  concrete  with  a  bonded 
construction  joint  as  specified  in  Article  21.3.4.4  of  Chapter  21,  Concrete  Structures,  of  these 
Standard Specifications. The Contractor shall prevent traffic from crossing the joint until such time 
as he has installed the joint assembly, as recommended by the joint Manufacturer, and the curing of 
all concrete has been completed. 

26.6.6 

Construction of Elastomeric Expansion Joints 

The Contractor shall obtain installation instructions from the supplier of the expansion joint material 
and  comply  with  the  procedures  specified  in  the  installation  of  the  joint.  Shop  drawings  shall  be 
submitted to the Engineer for approval. The adequacy of the joint design and installation details shall 
meet with the approval of the Engineer. The Contractor shall obtain the technical assistance of a 
field representative from the Manufacturer of the joint during its installation. Proper adjustment shall 
be made for temperature at the time of installation as indicated on the Contract plans. 

Joint assemblies shall be installed after the asphaltic pavement has been laid. Before the asphaltic 
pavement is laid the Contractor shall cover the joint opening with a strip of thin rigid material and a 
strip of strong paper or plastic equal in width to the joint assembly plus the header (if required) on 
each side. After the paving is finished, saw cuts shall be made by the Contractor across the asphaltic 
pavement either side of the joint plus side headers, and the asphaltic concrete between these cuts 
shall  be  broken  out.  The  protective  strips  shall  then  be  removed  and  the  concrete  surfaces 
thoroughly cleaned prior to installation of the joint assembly. Once the strip of asphaltic pavement is 
removed from between the saw cuts, the Contractor shall prevent construction traffic from crossing 
the joint until such time as he has installed the joint assembly and the headers have been completed. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-29 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

For the expansion joints specified, installation shall in no case be permitted until at least forty (40) 
days have elapsed after completion of the concrete post-tensioning operation. Permanent fixing of 
the joints to the structure shall only be carried out after the superstructure has been jacked to relieve 
the bearing shear and when the ambient temperature is within the range of the joint Manufacturer's 
recommendations and as approved by the Engineer. 

Concrete or metal surfaces on which the neoprene expansion joints are to be set shall be dry; clean 
and free from  dirt, grease,  latency,  and  contaninants;  level;  and  sound  with  no broken  or  spalled 
concrete. No joint shall be placed until the Engineer has inspected and approved the seat conditions. 

After coating the seat area with the specified sealant adhesive, the joint shall be positioned over the 
anchor bolts and the nuts securely tightened. All loose or long anchor bolts shall be corrected in a 
manner approved by the Engineer. 

All  joints  between  units,  around  connecting  bolts,  and  cavity  plugs  shall  be  carefully  sealed  with 
sealant in a neat workmanlike manner to seal out  water and protect against  corrosion. Neoprene 
surfaces to be in contact with sealant shall be buffed at the plant or wire brushed prior to installation 
to provide a bonding surface for the sealant. 

Prior to filling the space in the bolt wells, the Engineer will inspect the anchor bolts and tightening of 
the nuts to the Manufacturer's specified torque. Any wells sealed without the Engineer's approval 
shall be opened and redone at the Contractor's expense. 

The finished joint shall present a smooth, neat appearance with no protruding bolts or rough joints. 
Excess  sealant  shall  be  wiped  or  scraped  away  before  it  becomes  hard.  Upon  completion  of  an 
entire joint, the Contractor shall grind any uneven end butt connections flush. Any openings between 
butt ends not showing mastic to the top shall be cleaned and filled with mastic. The end of the joint 
at the curb faces shall be caulked with mastic. 

26.6.7 

Construction of Modular Bridge Joint Systems 

When  constructing  a  modular  bridge  joint  system  (MBJS),  the  Contractor  shall  follow  the 
M

anufacturer’s written installation guidelines and the guidelines outlined in this section.  

26.6.7.1 Shipping and Handling Modular Bridge Joint Systems 

Delivery of an MBJS to a job site and its storage at that site shall comply with the M

anufacturer’s 

written  recommendations  and  directions  from  the  Engineer.  The  Contractor  shall  ensure  that  all 
materials delivered to site is in original unopened containers bearing the following information: 

  Name of the Manufacturer 

  Name of product 

  Batch number, lot, etc. 

The Contractor shall repair any damage to the corrosion protection system to the satisfaction of the 
Engineer. Seals shall not be damaged or cut. 

26.6.7.2 Pre-installation Inspection for Modular Bridge Joint Systems 

Immediately  before  the  installation  of  an  MBJS,  the  Engineer  shall  inspect  the  MBJS  and  the 
blockout for the following conditions: 

a.  Proper alignment 

b.  Complete bond between the seals and the steel 

c.  Proper placement and effectiveness of studs or other anchorage devices 

d.  Proper placement of elastomeric springs and bearings 

e.  Proper placement of waterproofing membranes, if included 

f.  Clearance between the bottoms of 

the MBJS’s support boxes and the surface of the blockout; 

clearance shall be at least 75mm 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-30 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

Cutting a bridge deck

’s reinforcing steel can compromise the structural integrity of the blockout; the 

Contractor  shall  obtain  approval  from  the  Engineer  before  performing  such  cutting.  The  Engineer 
shall verify that reinforcing mesh or bars are at least 50mm from the edgebeam or anchorages and 
do not prevent the flow of concrete around the MBJS. 

No  bends  or  kinks  in  the  MBJS  steel  shall  be  allowed  (except  as  required  to  follow  the  roadway 
crown and grades or to accommodate sidewalks and traffic barriers). At no expense to the Owner, 
the  Contractor  shall  repair  or  replace  any  MBJS  that  exhibits  bends  or  kinks  to  the  E

ngineer’s 

satisfaction. 

Seals that are not fully connected to 

an assembly’s steel shall be fully connected at the expense of 

the Contractor. Headed concrete anchors shall be inspected visually and shall be given a light tap 
with a hammer. Any headed concrete anchor that does not have a complete end weld or that does 
not emit a ringing sound when struck with a light hammer tap shall be replaced. The Contractor shall 
carefully remove any headed concrete anchors along the length of the edgebeam that are more than 
25 mm from their intended locations, as shown on shop drawings, and any headed concrete anchors 
that are more than 6 mm too high (reducing cover); after removing an incorrectly placed anchor, the 
Contractor  shall  then  weld  a  new  anchor  in  the  proper  location.  The  Contractor  shall  bear  the 
expense for all such anchor replacement. 

26.6.7.3 Installation of Modular Bridge Joint Systems 

Before  installing  an  MBJS,  the  Contractor  shall  protect  the  blockout  and  supporting  system  from 
damage and construction traffic. 

a.  Setting a Gap Opening 

An MBJS shall be installed at the proper gap opening, corresponding to the installation temperature, 
as shown on approved shop drawings. The Contractor shall immediately remove opening devices 
after placing concrete. 

b.  Formwork 

The Contractor shall ensure that formwork prevents concrete from entering support boxes or from in 
any way impeding free movement of the MBJS. 

c.  Supporting a Modular Bridge Joint System during Concrete Placement 

An  MBJS  shall  have  full  support  throughout  the  placement  of  the  concrete.  Welds  for  temporary 
attachments  to  the  centrebeams  or  support  bars  that  are  used  to  erect  the  assembly  must  be 
removed  and  the  surface  ground  shall  be  smooth.  If  necessary,  the  Contractor  shall  repair  the 
corrosion protection system for an MBJS to the satisfaction of the Engineer using a method that the 
Engineer has approved. To reduce corrosion, an MBJS shall be electrically isolated by preventing 
contact between the MBJS and the bridge deck

’s steel reinforcement. 

d.  Placing Concrete for a Modular Bridge Joint System 

Concrete shall be controlled, mixed, and handled as specified in Chapter 4, Concrete Works, and 
Chapter  21,  Concrete  Structures.  The  blockout  shall  not  include  very-high-slump  concrete.  The 
Contractor shall not deposit concrete in forms until the Engineer has inspected and approved the 
placement of the reinforcement, conduits, anchorages, and pre-stressing steel. 

If an installation site has a vertical grade, the Contractor shall first place concrete on the downhill 
side  of  the  blockout.  Concrete  shall  be  vibrated  thoroughly  to  adequately  consolidate  concrete 
beneath the support boxes and edgebeams. The Contractor shall be careful not to displace forms 
and reinforcing steel. Concrete shall not be placed during heavy rain. 

e.  Finished Tolerances for a Modular Bridge Joint System 

An MBJS shall be inspected after installation and again after at least one year of traffic (or longer if 
there is a warranty period) to verify the following conditions: 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-31 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

  The 

MBJS’s top surfaces shall be recessed from the finished roadway profile from 0 mm to 

6 mm. 

  Elevations between the tops of centrebeams and edgebeams shall not differ by more than 3 

mm. Such variations shall be measured vertically from a straight line connecting the top of 
the deck profile on each side of the MBJS. 

  Gaps at either end of a seal or among the multiple gaps of an MBJS shall not differ by more 

than 12.5 mm. 

f.  Bridging a Modular Bridge Joint System after Installation 

Construction  loads  shall  not  be  allowed  on  the  MBJS  for  at  least  72  hours  after  installation  is 
completed.  If  it  is  necessary  to  cross  the  MBJS,  the  Contractor  shall  bridge  over  the  MBJS  in  a 
manner approved by the Engineer. 

g.  Removal of Forms and Debris from a Modular Bridge Joint System 

After installing a MBJS, the Contractor shall remove all forms and debris. 

h.  Watertightness Test for a Modular Bridge Joint System 

If  the  Contract  documents  require  such  testing,  the  Contractor  shall  test  an  installed  MBJS  for 
watertightness. After an MBJS has been installed and completed, the Contractor shall flood it for a 
at least one hour to a minimum depth of 76 mm. If a MBJS leaks, the Contractor shall repair it to the 
E

ngineer’s satisfaction and retest it at no expense to the Owner. Such repair shall comply with a 

procedure recommended by the 

assembly’s Manufacturer that has been approved by the Engineer. 

i.  Acceptance of Modular Bridge Joint System Installation 

An  MBJS  that  fails  inspection  or  testing  shall  be  replaced  or  repaired  to  the  satisfaction  of  the 
Engineer at the Contractor’s expense. Any proposed corrective procedure shall be submitted to the 
Engineer for approval before corrective work is begun. 

26.6.8 

Construction of Fixed Joint Seal 

The sealer shall be installed by suitable hand or machine tools and thoroughly secured in place with 
an approved adhesive which shall cover both sides of the sealer over the full area in contact with the 
sides of the joint. The adhesive may be applied to the sides of the joint or the sealer or both. The 
sealer shall be installed in a compressed condition and shall at all times be below the level of the 
surface  by  approximately  the  amount  shown  on  the  Contract  plans.  The  sealer  shall  be  in  one 
continuous  piece  for  the  full  width  of  transverse  joint  prior  to  being  installed  in  the  joint.  The 
continuous piece for installation shall not have more than one (1) butt splice within its length. The 
butt splice shall be a Manufacturer's splice. If this splice is torn or damaged it shall be repaired, prior 
to installation, using the Manufacturer's recommended adhesive. In longitudinal joints the sealer shall 
be in practical lengths. Any joints in the sealer material shall be adequately sealed with additional 
adhesive. 

After installation and prior to final acceptance, deck joint seals shall be tested, in the presence of the 
Engineer, for leakage of water through the joint. Any leakage of the joint shall be cause for rejection. 

The sealer shall be installed immediately after the removal of the curing cover, using an adhesive 
that  is  compatible  with  the  sealer  and  the  material  of  which  the  joint  surfaces  are  composed. 
Temperature limitations of the adhesive as guaranteed by the Manufacturer shall be observed. Joints 
shall be clean and free of foreign material immediately prior to the installation of the sealer. 

No  shipment  of  materials  shall  be  accepted  for  use  unless  the  material  complies  with  the 
requirements of these standard specifications. 

The materials shall not be used until the Contractor has been notified by the Engineer that they meet 
the requirements of these standard specifications. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-32 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

26.6.9 

Construction of Asphaltic Plug Joint 

1.  Joints shall be finished nominally flush with the road surface within the tolerance of the 

asphaltic surfacing specification. 

2.  Joint material shall be consolidated during installation in accordance with the 

manufacturer’s method statement. 

3.  Joints shall be installed between inside faces of opposing bridge railing on the deck 

structure to ensure continuity of waterproofing. 

4.  When completed the joint shall prevent the passage of water into the joint gap. 

26.7 

Warranty and Maintenance for Bridge Deck Joint Systems  

The Contractor shall obtain the warranty period from the Manufacturer for all types of bridge deck 
joint systems that are installed for the Project. Such warranties shall cover all elements of the bridge 
deck  joint  system.  During  this  period,  warranties  cover  any  defective  workmanship  and  product 
failure in accordance with the loading criteria of the structure, which should be certified before the 
recommendation of the specific joint system. 

The required warranty periods for each category of bridge deck joint system shall be as follows: 

-

  15 years for modular, strip, compression and finger type 

-

  10 years for elastomeric, fixed and asphaltic plug type 

 

The  Contractor  shall  provide  certification from the  Manufacturer of  bridge  deck joint  systems that 
shows  that  the  joint  system  materials  conform  to  the  requirements  outlined  in  Section  26.4.  The 
Contractor shall transfer to the Owner the M

anufacturer’s ten years warranty on each installation. A 

warranty claim may be filed for the cohesive or adhesive failure of the materials supplied or material 
failure due to weathering, and surface crazing, abrasion or tear failure resulting from normal traffic 
use. 

The Contractor shall inspect any bridge deck joint system that are installed on the Project within one 
year  of  opening  to  traffic  and  perform  any 

required  maintenance  to  ensure  the  joint  system’s 

functionality and durability. 

For the rest of the warranty period, if deficiencies are found, the Owner may inform the Manufacturer 
through the Contractor in writing of any defects and specify a required completion date for repairs.  

The joint system Manufacturer shall provide guidelines and manuals to support routine maintenance 
and replacement of the joint system and to support resolution of any concerns during the warranty 
period. 

26.8 

Documentation for Bridge Deck Joint Systems  

The Contractor shall provide all necessary documentation for approval of the design, manufacture, 
and  installation  of  a  bridge  desk joint  system  and for the  long term  inspection, maintenance,  and 
potential replacement of such system. Such documentation shall include the following: 

  Designs 

  Working drawings 

  Inspection and test plans 

  A certificate of compliance from the Manufacturer 

  Certified documentation 

of the structure’s loading criteria and load tests 

  Quality records  

  As-installed  details,  including  tabulated  benchmark  measurements  that  will  allow  the 

movement of the structure to be monitored during operation 

  Procedures for the inspection of the joint system 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-33 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

  Procedures for maintenance 

  A fully detailed method statement for the replacement of the bridge deck joint system 

  Risk assessments and appropriate safety information. 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 26-34 

C

HAPTER 

26:

 

B

RIDGE 

D

ECK 

J

OINT 

S

YSTEMS

 

 

First Edition -January 2018 

 

I

NDEX

 

 
adhesives, 5, 14, 30 
anchor bolts, 5, 18, 23, 30 
Anchorage, 25 
Blockouts, 27 
brochures, 11 
centerbeams, 5, 6 
certification, 10, 11, 12, 26, 33 
Compatibility, 8, 13, 19, 23 
compression seal expansion joints, 5 
concrete headers, 27 

Corrosion Protection

, 16, 26 

deck surfaces, 5 
Department of Transport, 26-3 
Design calculations, 12 
documentation, 10, 33, 34 
Documentation, 12, 33 

Drainage Collector

, 15 

edgebeams, 5, 25, 32 
elastomeric expansion joints, 5, 16, 17, 24 
epoxies, 5, 18 
Epoxy mortar, 18 
extruded steel channels, 5 
finger type expansion joints, 5, 15 
fixed joint seals, 5 
formwork, 32 
Hardness, 8, 15, 16, 20 
installation, 6, 9, 10, 11, 12, 13, 14, 15, 19, 24, 

25, 26, 27, 28, 29, 30, 31, 32, 33 

Lifting locations, 12 
modular bridge joint systems, 5 
molded units, 5, 16 
movement ranges, 5 
movements, 5, 6, 9, 11, 13, 16, 29 
Oil Deterioration, 16 
recesses, 5 
riding surface, 14, 19, 23, 28 
Risk assessments, 34 
saw cuts, 26, 29, 30 
sealants, 5 
sealed joints, 5, 19 
smooth ride, 26 
springs, 5, 6, 12, 18, 31 
stainless, 6, 18, 25, 26 
steel components, 13, 15, 16, 18 
strip seal, 5, 11, 14, 15, 16, 17, 29 
structural steel angles, 5 
studs, 5, 31 
support boxes, 5, 6, 25, 31, 32 
temporary, 12, 24, 28, 29, 32 
traffic, 10, 12, 19, 25, 28, 29, 30, 31, 32, 33 
two-component, 13, 14, 19, 23 
warranty, 32, 33 
water tightness, 5 

Welding, 7, 12, 19 
wheel loads, 5, 16 

 

 

 

 

 

 

 

STANDARD CONSTRUCTION SPECIFICATIONS 

PART 2 

ROAD STRUCTURES 

 

CHAPTER 27 - RAILINGS 

 

 

 

 

 

 

 

DOCUMENT NO: TR- 

FIRST EDITION 

JANUARY 2018

 

 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page i 

C

HAPTER 

27:

 

R

AILINGS

 

First Edition -January 2018 

 

 

Chapter 27: Railings 

T

ABLE OF 

C

ONTENTS

 

Table of Contents............................................................................................................................. i

 

List of Figures ................................................................................................................................. ii

 

List of Tables .................................................................................................................................. ii

 

27

 

Railings ........................................................................................................................... 27-1

 

27.1

 

Reference Standards and Codes ................................................................................. 27-1

 

27.2

 

Working Drawings Submission .................................................................................... 27-4

 

27.3

 

Materials for Railings ................................................................................................... 27-4

 

27.3.1

 

Aluminium Railing ................................................................................................. 27-5

 

27.3.2

 

Steel Railing ......................................................................................................... 27-7

 

27.3.3

 

Metal Beam Railing ............................................................................................... 27-8

 

27.3.4

 

Stainless Steel Railing .......................................................................................... 27-8

 

27.3.5

 

Copper Alloys Railing............................................................................................ 27-8

 

27.3.6

 

Concrete Railing ................................................................................................... 27-8

 

27.3.7

 

Screening for Railings ........................................................................................... 27-8

 

27.4

 

Construction Requirements for Railings ....................................................................... 27-8

 

27.4.1

 

General ................................................................................................................. 27-8

 

27.4.2

 

Constructing Aluminium Railing ............................................................................ 27-9

 

27.4.3

 

Constructing Steel Railings ................................................................................. 27-10

 

27.4.4

 

Constructing Stainless Steel Railing ................................................................... 27-12

 

27.4.5

 

Constructing Copper Alloys Railing ..................................................................... 27-12

 

27.4.6

 

Constructing Concrete Railing ............................................................................ 27-13

 

27.4.7

 

Constructing Screening for Railings .................................................................... 27-13

 

27.4.8

 

Welding for Railings ............................................................................................ 27-13

 

27.4.9

 

Storing Construction Materials for Railings ......................................................... 27-14

 

27.4.10

 

Constructing Temporary Railings ........................................................................ 27-14

 

27.5

 

Testing and Acceptance of Railings ........................................................................... 27-14

 

27.5.1

 

General ............................................................................................................... 27-14

 

27.5.2

 

Bridge Railing Test ............................................................................................. 27-14

 

27.5.3

 

Crash Testing Policy ........................................................................................... 27-14

 

27.6

 

Spares for Railings .................................................................................................... 27-15

 

27.6.1

 

Constructing Spares for Railings ......................................................................... 27-15

 

Index   ...................................................................................................................................... 27-15

 

 

 

 

S

TANDARD 

C

ONSTRUCTION SPECIFICATIONS

 

PART 

2

 

 

R

OAD 

S

TRUCTURES

 

 

 

Page 27-1 

C

HAPTER 

27:

 

R

AILINGS

 

First Edition -January 2018 

 

27 

RAILINGS 

This chapter outlines standards and requirements for furnishing materials and constructing railing of 
concrete, steel, aluminium, or a combination of these materials for the Project. 

This chapter’s specifications apply to all work and materials related to railing construction, including 
necessary anchorage for the railing on bridges, culverts, walls, or other structures as shown on the 
Contract plans. These specifications apply to hand and pedestrian railings, bridge railings (which are 
sometimes called bridge or traffic barriers), and railings for similar purposes. Railings shall conform 
to  the  type  and  details  specified  in  the  Contract  documents  for  the  location  where  they  are 
constructed. 

27.1 

Reference Standards and Codes 

Standards  and  codes  for  railings  shall  be  as  specified  in  these  specifications,  in  the  Contract 
documents, if any, and the following, in their latest edition: 

AA 

 

 

 

 

Aluminum Association; 

AA ADM-1 

Aluminum Association - Aluminum Design Manual, 2010 
Edition; 

AASHTO LRFD 

American Association of State Highway and Transportation 
Officials - Load and Resistance Factor Design, Bridge 
Construction Specifications; 

AASHTO LRFD 

American Association of State Highway and Transportation 
Officials - Load and Resistance Factor Design, Bridge Design 
Specifications; 

AASHTO 

Standard Specifications for Transportation Materials and 
Methods of Sampling and Testing; 

AASHTO GSH-9 

 

 

Guide Specifications for Highway Construction, 9th Edition; 

AASHTO/AWS 

 

 

Bridge Welding Code; 

D1.5M/D1.5:2010 

AASHTO MASH 

 

 

AASHTO Manual for Assessing Safety Hardware; 

ADQCC (TR-516) 

 

 

Road Structures Design Manual; 

ANSI   

 

 

 

American National Standards Institute; 

ANSI/AWS D1.2/ 

 

 

Structural Welding Code

—Aluminum; 

D1.2M:2003 

ASTM   

 

 

 

American Society for Testing and Materials; 

AWS   

 

 

 

American Welding Society; 

AWS D 1.6/ 

 

 

 

Structural Welding Code - Stainless Steel; 

D 1.6M: 2007 

NCHRP350 

National Cooperative Highway Research Program Report 350 
- Recommended Procedures for the Safety Performance 
Evaluation of Highway Features; 

NOMMA 

 

 

 

National Ornamental & Miscellaneous Metals Association; 

NOMMA 

 

 

 

Voluntary Joint Finish Guidelines; 

Guideline 1  

 

 

 

 

 

 

 