BRC-26 < COMPONENT DIAGNOSIS > [ABS] C1109 POWER AND GROUND SYSTEM C1109 POWER AND GROUND SYSTEM Description INFOID:0000000000924978 Power is supply from the battery to ABS actuator and electric unit (control unit). DTC Logic INFOID:0000000000924979 DTC DETECTION LOGIC DTC CONFIRMATION PROCEDURE 1. CHECK SELF-DIAGNOSIS RESULTS Check the self-diagnosis results. Is above displayed on the self-diagnosis display? YES >> Proceed to diagnosis procedure. Refer to . NO >> INSPECTION END Diagnosis Procedure INFOID:0000000000924980 INSPECTION PROCEDURE 1. CHECK CONNECTOR 1. Turn ignition switch OFF. 2. Disconnect ABS actuator and electric unit (control unit) connector. 3. Check terminal for deformation, disconnection, looseness, and so on. If any malfunction is found, repair or 4. Reconnect connector and then perform the self-diagnosis. Refer to . Is any item indicated on the self-diagnosis display? YES >> GO TO 2. NO >> Poor connection of connector terminal. Repair or replace connector. 2. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect ABS actuator and electric unit (control unit) connector. 3. Turn ignition switch ON or OFF and check voltage between ABS actuator and electric unit (control unit) 4. Reconnect ABS actuator and electric unit (control unit) connector. Is the inspection result normal? YES >> GO TO 3. DTC Display item Malfunction detected condition Possible cause C1109 BATTERY VOLTAGE When the ABS actuator and electric unit (control unit) • Harness or connector (control unit) • Fuse tem Self-diagnosis results BATTERY VOLTAGE [ABNORMAL] ABS actuator and electric unit (control unit) — Condition Voltage Connector Terminal E34 18 Ground Ignition switch: ON Battery voltage Ignition switch: OFF Approx. 0 V |