CVT SHIFT LOCK SYSTEM TM-283 < COMPONENT DIAGNOSIS > [CVT: RE0F10A] C E F G H I J K L M A B TM N O P Is the inspection result normal? YES >> GO TO 2. NO >> • Harness for short or open between ignition switch and control device harness connector termi- nal 3 • 10 A fuse [No. 55, located in the IPDM E/R] 2. CHECK HARNESS BETWEEN CONTROL DEVICE AND STOP LAMP SWITCH 1. Turn ignition switch OFF. 2. Disconnect control device harness connector and stop lamp switch connector. 3. Check continuity between control device harness connector terminal and stop lamp switch connector ter- 4. If OK, check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 3. NO >> Repair open circuit or short to ground or short to power in harness or connectors. 3. CHECK STOP LAMP SWITCH Check continuity between stop lamp switch harness connector terminal 3 and 4. Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace damaged parts. 4. CHECK GROUND CIRCUIT Check continuity between stop lamp switch harness connector and ground. Is the inspection result normal? YES >> GO TO 5. NO >> Repair open circuit or short to ground or short to power in harness or connectors. 5. CHECK CONTROL DEVICE 1. Move selector lever to “P” position. 2. Check continuity between control device harness connector. Is the inspection result normal? Control device harness connector Ground Voltage (Approx.) Connector Terminal M57 3 Battery Voltage Control device harness connector Stop lamp switch harness connector Continuity Connector Terminal Connector Terminal M57 4 E115 3 Existed Stop lamp switch harness connector Condition Continuity Connector Terminal E115 3 4 Depressed brake pedal Existed Released brake pedal Not existed Stop lamp switch harness connector Ground Continuity Connector Terminal E115 4 Existed Control device harness connector Continuity Connector Terminal M57 3 4 Existed |