P0381 GLOW CONTROL SYSTEM EC-1367 < COMPONENT DIAGNOSIS > [K9K] C D E F G H I J K L M A EC N P O 2. Also check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 5. NO >> Repair open circuit or short to ground or short to power in harness or connectors. 5. CHECK GLOW RELAY OUTPUT CIRCUIT FOR OPEN AND SHORT 1. Disconnect glow plug harness connector. 2. Check the continuity between glow plug harness connector and ECM harness connector. 3. Also check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 6. NO >> Repair open circuit or short to ground or short to power in harness or connectors. 6. CHECK GLOW PLUG EC-1371, "Component Inspection" . Is the inspection result normal? YES >> GO TO 7. NO >> Replace malfunctioning glow plug. 7. CHECK INTERMITTENT INCIDENT GI-39, "Intermittent Incident" . Is the inspection result normal? YES >> Replace glow relay. NO >> Repair or replace. Component Inspection INFOID:0000000001091182 1. CHECK GLOW PLUG 1. Turn ignition switch OFF. 2. Disconnect glow plug harness connector. 3. Check resistance between glow plug terminals as follows. Is the inspection result normal? YES >> INSPECTION END NO >> Replace malfunctioning glow plug. Glow relay ECM Continuity Connector Terminal Connector Terminal F94 8 F68 76 Existed Glow relay Glow plug Continuity Cylinder Connector Terminal Connector Terminal 1 F94 2 F95 1 Existed 2 7 F96 1 3 1 F97 1 4 6 F98 1 Terminal Resistance 1 and engine ground Not less than 2 Ω [at 20 ° C (68 ° F)] |