(4) HECU voltage of 10 ~ 12V is preferred during exhaust mode operation. As battery on vehicle is used when using diagnostic instruments, there should be no problem. (If exhaust mode operation is repeated with high voltage, ECU coil may be damaged.) 4. Exhaust fault confirm methods (Table 3-21) Table 3-21 Leak experiment Difference Type ECU operation Excessive leak Minim leak Remark Case 1 Normal O.K O.K Normal operation, no rework Case 2 Normal O.K N.G Abnormal operation, rework Case 3 Normal N.G N.G Abnormal operation, rework Case 4 No O.K O.K Abnormal operation, rework
exhaust and filling in HECU can not be operated). (5) After stepping on the brake pedal, open the bleed screw on the caliper or drum brake to exhaust the inside air. This operation should be carried out for all wheels before that the brake fluid exhausted through the bleed screw contains no air and the brake pedal is hard enough. When using the reassembled equipment that can form vacuum or is filled with brake fluid, refer to item (10). (6) Operate the exhaust mode with the reassembled equipment or diagnostic instrument and step on the brake pedal, if there is no reaction force, repeat stepping on and releasing the pedal until the exhaust mode is finished. (Exhaust mode: repeat the process of start and stop of normally closed solenoid valve with interval of 2 seconds for 1 minute, and keep motor working. The repeat of stepping on and releasing of pedal should be carried out on the normally closed solenoid valve while motor is operating.) 185 |