Parameters Reset Tables
Parameter values that vary According to drive rating and reset type
The table below lists lists the parameters whose values, after a reset, depend on the drive model and the reset
type ([Parameter reset] (tYP) = 1, [Parameter reset] (tYP) = 2, or [Parameter reset] (tYP) = 3). To
determine the value of a parameter after a reset:
1. Locate the drive model number in the first column.
2. Read across the row to the group of columns that corresponds to the reset type ([Parameter reset] (tYP) =
1, [Parameter reset] (tYP) = 2, or [Parameter reset] (tYP) = 3).
3. Locate the parameter code in the columns corresponding to the reset type.
The number that appears at the intersection of the drive model number and the parameter code is the
parameter’s value after a reset of the specified type.
Parameters whose values after a reset are drive model and reset type dependant
Factory reset tYP = 3
50 Hz reset tYP = 1
60 Hz reset tYP = 2
Reference
tHr
F173
F185
F601
tHr
F173
F185
F415
F416
F417
F601
tHr
F173
F185
F415
F416
F417
F601
%
%
%
%
%
%
%
A
%
rpm
%
%
%
%
A
%
rpm
%
ATV212H075M3X
100
100
110
110
100
100
110
3.5
64
1400
110
100
100
110
3.0
60
1700
110
ATV212HU15M3X
100
100
110
110
100
100
110
6.1
61
1420
110
100
100
110
5.8
59
1715
110
ATV212HU22M3X
100
100
110
110
100
100
110
8.8
59
1430
110
100
100
110
8.0
61
1715
110
ATV212HU30M3X
100
100
110
110
100
100
110
12.5
63
1420
110
100
100
110
12.4
48
1760
110
ATV212HU40M3X
100
100
110
110
100
100
110
15.8
61
1425
110
100
100
110
15.2
51
1769
110
ATV212HU55M3X
100
100
110
110
100
100
110
20.6
57
1430
110
100
100
110
22.0
53
1780
110
ATV212HU75M3X
100
100
110
110
100
100
110
26.3
54
1450
110
100
100
110
28.0
42
1780
110
ATV212HD11M3X
100
100
110
110
100
100
110
36.9
53
1450
110
100
100
110
36.0
39
1766
110
ATV212HD15M3X
100
100
110
110
100
100
110
49.5
53
1455
110
100
100
110
48.0
36
1771
110
ATV212HD18M3X
100
100
110
110
100
100
110
61.0
53
1455
110
100
100
110
61.0
39
1771
110
ATV212HD22M3X
100
100
110
110
100
100
110
68.0
53
1460
110
100
100
110
68.0
36
1771
110
ATV212HD30M3X
100
100
110
110
100
100
110
93.0
50
1460
110
100
100
110
93.0
33
1771
110
ATV212H075N4
100
100
110
110
100
100
110
2.0
64
1400
110
100
100
110
1.5
60
1720
110
ATV212HU15N4
100
100
110
110
100
100
110
3.5
61
1420
110
100
100
110
2.9
59
1700
110
ATV212HU22N4
100
100
110
110
100
100
110
5.1
59
1430
110
100
100
110
4.0
61
1715
110
ATV212HU30N4
100
100
110
110
100
100
110
7.2
63
1420
110
100
100
110
6.2
48
1715
110
ATV212HU40N4
100
100
110
110
100
100
110
9.1
61
1425
110
100
100
110
7.6
51
1760
110
ATV212HU55N4
100
100
110
110
100
100
110
11.9
57
1430
110
100
100
110
11.0
53
1769
110
ATV212HU75N4
100
100
110
110
100
100
110
15.2
54
1450
110
100
100
110
14.0
42
1780
110
ATV212HD11N4
100
100
110
110
100
100
110
21.3
53
1450
110
100
100
110
21.0
39
1780
110
ATV212HD15N4
100
100
110
110
100
100
110
28.6
53
1455
110
100
100
110
27.0
36
1766
110
ATV212HD18N4
100
100
110
110
100
100
110
35.1
53
1455
110
100
100
110
35.1
39
1771
110
ATV212HD22N4S
100
100
110
110
100
100
110
41.7
53
1460
110
100
100
110
41.7
36
1780
110
ATV212HD22N4
100
100
110
110
100
100
110
41.7
53
1460
110
100
100
110
41.7
36
1771
110
ATV212HD30N4
100
100
110
110
100
100
110
55.0
50
1460
110
100
100
110
55.0
33
1771
110
ATV212HD37N4
100
100
110
110
100
100
110
67
51
1475
110
100
100
110
67
31
1771
110
ATV212HD45N4
100
100
110
110
100
100
110
81
51
1475
110
100
100
110
71
34
1771
110
ATV212HD55N4
100
100
110
110
100
100
110
99
53
1480
110
100
100
110
86
31
1771
110
ATV212HD75N4
100
100
110
110
100
100
110
135
53
1480
110
100
100
110
114
31
1771
110
200
Parameters Reset Tables
Parameter values that do not change if reset
The parameters listed in the table below cannot be reset. The table lists the default settings of these parameters.
Parameters whose values do not change if a reset is performed
Parameter
Description
Default Value
FM
[AO scaling]
-
FMSL
[AO funct. selection]
0
F109
[VIA selection]
0
F470
[VIA bias]
128
F471
[VIA gain]
148
F472
[VIB bias]
128
F473
[VIB gain]
148
F880
[Free ID parameter]
0
201
Parameters Reset Tables
202
User Settings Tables
User Settings Tables
18
Use the Configuration Setting Table to look up parameter default settings, to record customized parameter
settings, and to look up sections of the manual, by page number, that contain detailed parameter descriptions.
Configuration Setting Table
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
FC
87
[Local speed ref.]
Hz
-
[Low limit frequency] (LL) to [Upper limit freq] (UL)
0.0
0
[Disabled]
AU1
95
[Auto ramp]
-
1
[Enable]
1
2
[ACC only]
0
[Factory set]
1
[Run permissive]
AU4
67
[Auto set function]
-
2
[3-wire]
0
3
[+/- Speed]
4
[4-20mA speed ref]
0
[Logic inputs]
CMOd
87
[Command mode sel]
-
1
[HMI]
0
2
[Communication]
1
[Ref source VIA]
2
[Ref source VIB]
FMOd
87
[Frequency mode sel]
-
3
[HMI reference]
1
4
[Serial com ref.]
5
[+/- Speed]
0
[Motor frequency]
1
[Motor current]
2
[Speed ref]
3
[DC bus U]
4
[Motor U]
5
[Input power]
6
[Output power]
7
[motor torque]
8
[Torque I]
9
[Motor thermal]
FMSL
118
[AO funct. selection]
-
0
10
[Drive thermal]
11
[Do not use]
12
[Internal reference]
13
[VIA]
14
[VIB]
15
[Fixed 100%]
16
[Fixed 50%]
17
[Fixed 100%]
18
[Com data]
19
[Do not use]
FM
118
[AO scaling]
-
-
-
-
203
User Settings Tables
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
0
[No action]
1
[50 Hz reset]
2
[60 Hz reset]
3
[Factory set]
4
[Trip cleared]
tYP
66
[Parameter reset]
-
0
-
5
[Cumul time clear]
6
[EtYP fault reset]
7
[Save parameters]
8
[Recall parameters]
9
[Elapse time reset]
0
[Run FW]
1
[Run rev.]
Fr
87
[Local mot. direction]
-
0
2
[Run FW+rev]
3
[Run rev+FW]
Model
93
ACC
[Acceleration time 1]
s
-
0.0 - 3200
depen-
163
dent
Model
93
dEC
[Deceleration time 1]
s
-
0.0 - 3200
depen-
162
dent
92
FH
[Max frequency]
Hz
-
30.0
- 400.0
50.0
162
92
UL
[Upper limit freq]
Hz
-
0.5 - [Max frequency] (FH)
50.0
161
92
LL
[Low limit frequency]
Hz
-
0.0 - [Upper limit freq] (UL)
0.0
161
74
uL
[Motor rated freq.]
Hz
-
25.0
- 200.00
50.0
161
230 V
50 - 330
230
74
models
uLu
[Motor Rated Voltage]
V
160
460 V
50 - 660
400
models
0
[Constant V/Hz]
1
[Variable Torque]
2
[Cst V/Hz+Boost]
71
Pt
[Mot cont. mode sel.]
-
3
[SVC]
1
82
4
[Economy]
5
[Do not use]
6
[PM control]
Model
ub
73
[Motor Voltage Boost]
%
-
0.0
- 30.0
depen-
dent
tHr
74
[Motor thermal prot.]
%/A
-
10 - 100% of drive’s output current rating
100%
0
[Std mot. protect.]
1
[Std & stall mot. prot]
2
[Self cool]
3
[Slf cool stall ov.load]
OLM
146
[Motor overload prot]
-
0
4
[Forced cool prot]
5
[Forc cool stall prot]
6
[Forced cool]
7
[F cool & stall ov load]
Sr1
123
[Preset speed 1]
Hz
1
[Low limit frequency] (LL) to [Upper limit freq] (UL)
15
Sr2
123
[Preset speed 2]
Hz
1
[Low limit frequency] (LL) to [Upper limit freq] (UL)
20
Sr3
123
[Preset speed 3]
Hz
1
[Low limit frequency] (LL) to [Upper limit freq] (UL)
25
Sr4
123
[Preset speed 4]
Hz
1
[Low limit frequency] (LL) to [Upper limit freq] (UL)
30
Sr5
123
[Preset speed 5]
Hz
1
[Low limit frequency] (LL) to [Upper limit freq] (UL)
35
Sr6
123
[Preset speed 6]
Hz
1
[Low limit frequency] (LL) to [Upper limit freq] (UL)
40
Sr7
123
[Preset speed 7]
Hz
1
[Low limit frequency] (LL) to [Upper limit freq] (UL)
45
F100
125
[Freq. 1 reached]
Hz
-
0.0 to [Max frequency] (FH)
0.0
204
User Settings Tables
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
F101
125
[Freq. 2 reached]
Hz
-
0.0 to [Max frequency] (FH)
0.0
F102
125
[Freq.2 bandw.]
Hz
-
0.0 to [Max frequency] (FH)
2.5
F108
122
[Logic Funct 1 active]
-
0 - 73
See table on page 101
0
0
AI
F109
100
[VIA selection]
-
1
LI sink
0
2
LI source
F110
122
[Logic Funct 2 active]
-
0 - 73
See table page 194
1
F111
100
[LI F selection]
-
0 - 72
See table page 194
2
F112
100
[LI R selection]
-
0 - 72
See table page 194
6
F113
100
[LI RES selection]
-
0 - 72
See table page 194
10
F118
100
[VIA LI selection]
-
0 - 73
See table page 194
7
0 - 61,
F130
119
[RY Relay Function 1]
-
See table page 194
4
254, 255
0 - 61,
F132
120
[FL Relay Function]
-
See table page 194
11
254, 255
0 - 61,
F137
124
[RY Relay Function 2]
-
See table page 194
255
254, 255
0
Function 1and 2
F139
124
[RY logic select.]
-
0
1
Function 1 or 2
F146
119
[RY delay]
s
-
0.0 - 60.0 s
0.0
F147
120
[FL Relay delay]
s
-
0.0 - 60.0 s
0.0
F160
116
[VIA rel thresh. logic]
%
-
0 - 100
0
F161
116
[VIA threshold hyst.]
%
-
0 - 20
3
F162
116
[VIB rel thresh. logic]
%
-
0 - 100
0
F163
116
[VIB threshold hyst.]
%
-
0 - 20
3
F167
126
[Freq band det range]
Hz
-
0.0 to [Max frequency] (FH)
2.5
F170
79
[Mot 2 rated Freq.]
Hz
-
25.0 to 200.0
50.0
230V
50 to 330
230
model
F171
79
[Motor 2 rated Volt]
V
460V
50 to 660
400
model
Model
F172
79
[Motor 2 Volt Boost]
%
-
0 - 30
depen-
dant
F173
79
[Motor 2 Overload]
%/A
-
10 - 100% of drive rating
100
F185
79
[Mot. 2 current limit]
%/A
-
10 - 110%
110
0
[Enable]
0
F200
118
[Auto/man speed ref]
-
1
[Disable]
F201
116
[VIA ref point 1]
%
-
0 - 100
0
F202
116
[VIA freq. point 1]
Hz
-
0.0
- 200.0
0.0
F203
116
[VIA freq. point 2]
%
0 - 100
100
F204
116
[VIA freq. point 2]
Hz
0.0
- 200.0
50.0
1
[VIA]
2
[VIB]
F207
88
[Remote spd ref 2]
-
3
[HMI]
2
4
[Communication]
5
[+/- Speed]
F210
116
[VIB ref. point 1]
%
0 - 100
0
F211
116
[VIB freq. point 1]
Hz
0.0
- 200.0
0.0
F212
116
[VIB ref. point 2]
%
0 - 100
100
F213
116
[VIB freq. point 2]
Hz
0.0
- 200.0
50.0
F240
92
[Mot start freq.]
Hz
-
0.5
- 10.0
0.5
F241
154
[Freq. pedestal]
Hz
-
0.0 - [Max frequency] (FH)
0.0
205
User Settings Tables
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
F242
154
[Freq. pedestal hyst.]
Hz
-
0.0 - [Max frequency] (FH)
0.0
F250
98
[DC brake start freq.]
Hz
-
0.0 - [Max frequency] (FH)
0.0
F251
98
[DC braking current]
%/A
-
0 - 100%
50
F252
98
[DC braking time]
s
-
0.0
- 20.0
1.0
0
[Disable]
F256
88
[Time limit low spd]
s
0.0
1
[Enable]
F264
124
[+speed LI resp time]
s
-
0.0
- 10.0
0.1
F265
124
[+speed freq. step]
Hz
-
0.0 - [Max frequency] (FH)
0.1
F266
124
[- speed LI resp time]
s
-
0.0
- 10.0
0.1
F267
124
[- speed freq. step]
Hz
-
0.0 - [Max frequency] (FH)
0.1
F268
124
[Init +/- Speed]
Hz
-
0.0 - [Max frequency] (FH)
0.0
0
[Disable]
F269
124
[Init +/- Speed memo]
-
1
1
[Enable]
F270
97
[Jump frequency 1]
Hz
-
0.0 - [Max frequency] (FH)
0.0
F271
97
[Jump bandwidth 1]
Hz
-
0.0
- 30.0
0.0
F272
97
[Jump frequency 2]
Hz
-
0.0 - [Max frequency] (FH)
0.0
F273
97
[Jump bandwidth 2]
Hz
-
0.0
- 30.0
0.0
F274
97
[Jump frequency 3]
Hz
-
0.0 - [Max frequency] (FH)
0.0
F275
97
[Jump bandwidth 3]
Hz
-
0.0
- 30.0
0.0
F294
89
[Forced speed freq.]
Hz
-
[Low limit frequency] (LL) - [Upper limit freq] (UL)
50.0
0
[No bumpless]
1
F295
88
[Switch rem/Local]
-
1
[Bumpless]
Model
F300
95
[Switch. freq. level]
kHz
-
6.0
- 16.0
depen-
dent
0
[Disable]
1
[Brief power loss]
F301
137
[Catch on fly]
-
2
[Run restored]
3
3
[Power loss, run]
4
[Each start]
0
[Disabled]
F302
138
[Supply loss behav.]
-
1
[Do not use]
0
2
[Freewheel]
0
[Disabled]
135
F303
[Number auto reset]
-
0
169
1-10
[Number of fault reset attempts]
0
[Enable]
1
[Disabled]
F305
139
[Overvoltage fault]
-
2
2
[Quick deceleration]
3
[Dyn. deceleration]
0
[Motor volt limit]
1
[Line & mot correct.]
F307
78
[Mot volt limitation]
-
3
2
[No action]
3
[U Line correction]
0
[Fw & Rev.]
96
F311
[Motor direction]
-
1
[Fw only]
1
160
2
[Rev. only]
0
[Disable]
F312
96
[Noise reduction]
-
0
1
[Enable]
0
[Fixed]
1
[Auto]
F316
96
[Switch. freq. mode]
-
1
2
[460 V fixed]
3
[460 V Auto]
F320
156
[Load gain]
%
-
0 - 100
0
F323
156
[Load gain offset]
%
-
0 - 100
10
0
[No]
F324
160
[Driving Scroll]
-
0
1
[Yes]
206
User Settings Tables
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
0
[No]
F325
170
[Pre-start Scroll]
-
0
1
[Yes]
F326
170
[Pre-Start time]
s
-
0 - 6000
10
F327
171
[Pre-Start speed]
Hz
-
0.0 - [Upper limit freq] (UL)
50
F328
171
[LL speed time]
s
-
0 - 10
2
F329
171
[Pre-start delay]
s
-
0 - 120
3
0
[No]
F330
172
[Std Oiling Cycle]
-
0
1
[Yes]
172
F331
[Std Oiling Speed]
Hz
-
0.0 - [Upper limit freq] (UL)
70
173
F332
172
[Std Oiling Time]
s
0 - 6000
30
F333
172
[Std Oil. Cycle Frq.]
Hours
0 - 24
24
0
[No]
F334
173
[Low Speed Oiling]
-
0
1
[Yes]
F335
173
[LL Speed for Oiling]
Hz
-
0.0 - [Upper limit freq] (UL)
50
F336
173
[LLS Time for Oiling]
mn
-
0.0 - 360
60
F337
173
[Oiling Time at LLS]
s
-
0.0 - 6000
30
0
[No]
F338
174
[Scroll Protection]
-
0
1
[Yes]
F339
174
[Cavitation Frq.]
Hz
-
[Low limit frequency] (LL) - [Upper limit freq] (UL)
30
0
[No]
F349
175
[Discharge gas]
-
1
[VIA]
0
2
[VIB]
F350
175
[High Thd]
%
-
0 - 100
65
F351
175
[Cooling Frq.]
Hz
-
[Low limit frequency] (LL) - [Upper limit freq] (UL)
50
F352
175
[Cooling Time]
mn
-
0 - 30
3
F353
175
[High high Thd]
%
-
0 - 100
70
F354
175
[Re-Start Delay]
mn
-
0 - 30
5
0
[No]
F355
176
[Crankcase heating]
-
0
1
[Yes]
F359
121
[PID ctrl wait time]
s
-
0 - 2400
0
0
[No PID]
F360
120
[PID control enable]
-
1
[PID by VIA]
0
2
[PID by VIB]
F362
120
[PID Prop Gain]
-
-
0.01
- 100.0
0.30
F363
120
[PID Integral Gain]
-
-
0.01
- 100.0
0.20
F366
121
[PID Derivative Gain]
-
-
0.00
- 2.55
0.00
0
[No]
F380
121
[PID reverse error]
-
0
1
[Yes]
F391
122
[Stop on LL hyst]
Hz
-
0.0 - [Max frequency] (FH)
0.2
F392
122
[PID wake up (thres)]
Hz
-
0.0 - [Max frequency] (FH)
0.0
F393
122
[PID wake up, feedb]
Hz
-
0.0 - [Max frequency] (FH)
0.0
0
[Disabled]
1
[Initialize constant]
76
2
[Tun Static]
F400
[Auto-tuning drive]
-
0
165
3
[Tun Dyn.]
4
[Tun Prst 1]
5
[Tun Prst 2]
79
F401
[Slip Compensation]
%
-
0 - 150
50
162
Model
79
F402
[Auto Torque Boost]
%
-
0.0
- 30.0
depen-
162
dent
207
User Settings Tables
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
Model
F405
82
[Motor rated freq.]
kW
-
0.01 - 75
depen-
dent
Model
74
F415
[Motor rated current]
A
-
0.1
- 200.0
depen-
161
dent
Model
F416
74
[Mot no-load current]
%
-
10.0
- 100.0
depen-
dent
Model
74
F417
[Motor rated speed]
rpm
-
100 - 15000
depen-
161
dent
80
F418
[Frequency loop gain]
-
-
1 - 150
40
166
80
F419
[Freq. loop stability]
-
-
1 - 100
20
166
Model
85
F420
[Torque Boost Coef]
%
-
0 - 200
depen-
166
dent
F458
165
[Current loop gain]
Hz
-
0 - 100
0
F470
117
[VIA bias]
-
-
0 - 255
128
F471
117
[VIA gain]
-
-
0 - 255
148
F472
117
[VIB bias]
-
-
0 - 255
128
F473
117
[VIB gain]
-
-
0 - 255
148
F480
77
[No load cur. coef]
-
-
100 - 130
100
F481
144
[In noise comp. filter]
s
-
0 - 9999
0
F482
144
[In noise Inhibit filter]
s
-
0 - 9999
442
F483
144
[In noise inhibit gain]
-
-
0.0
- 300.0
100.0
F484
144
[Pwr supply adj. gain]
-
-
0.0 to 2.0
0.0
F485
77
[Stall control coef. 1]
-
-
10 - 250
100
F492
77
[Stall control coef. 2]
-
-
50 - 150
100
Model
F494
77
[Mot. adj coefficient]
-
-
DO NOT ADJUST
depen-
dant
77
F495
[Motor voltage coef.]
%
-
90 - 120
104
166
F496
77
[PWM adj. coef.]
kHz
-
0.1
- 14.0
14.0
F500
93
[Acceleration time 2]
s
1
0.0 - 3200
20.0
F501
93
[Deceleration time 2]
s
1
0.0 - 3200
20.0
0
[Linear]
F502
94
[Acc/dec 1 pattern]
-
1
[S-ramp 1]
0
2
[S-ramp 2]
0
[Linear]
F503
94
[Acc/dec 2 pattern]
-
1
[S-pattern 1]
0
2
[S-pattern 2]
1
[Ramp 1]
F504
95
[Ramp switching]
-
1
2
[Ramp 2]
F505
95
[Commut. ramp freq.]
Hz
-
0.0 - [Upper limit freq] (UL)
0.0
F506
94
[Acc/Dec S-pat start]
%
-
0 - 50
10
F507
94
[Acc/Dec S-pat end]
-
-
0 - 50
10
0
[No feedback]
1
[LIH set]
F580
128
[Damper fdb type]
-
2
[LIL set]
0
3
[Com. LIH set]
4
[Com. LIL set]
208
User Settings Tables
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
F581
128
[Time open Damper]
-
-
0.05 to 300.00 s
60.00
F582
128
[Time close Damper]
-
-
0.05 to 300.00 s
60.00
0
[No fault]
F583
128
[Damper flt behavior]
-
1
[Freewheel stop]
1
2
[Ramp stop]
73
F601
[Motor Current Limit]
%/A
-
10 - 110%
110%
161
0
[Cleared]
F602
138
[Drive fault memory]
-
0
1
[Retained]
0
[Freewheel]
F603
126
[Ext. fault stop Mode]
-
1
[Ramp stop]
0
2
[DC braking]
F604
126
[DC brk time ext flt]
s
-
0.0
- 20.0
1.0
0
[Disabled]
1
[First start]
2
[Each start]
F605
140
[Output phase loss]
-
3
3
[During run]
4
[Permanent]
5
[Catch on fly]
F607
74
[Mot overload time]
s
-
10 - 2400
300
0
[Disable]
F608
138
[Input phase loss]
-
1
1
[Enable]
F609
141
[Underload band]
%
-
1 - 20
10
0
[Alarm]
F610
141
[Underload det.]
-
0
1
[Fault]
F611
141
[Underload level]
%/A
-
0 - 100%
0
F612
141
[Underload det. time]
s
-
0 - 255
0
0
[Each time (std)]
1
[One time (std)]
F613
142
[Short circuit det.]
-
0
2
[Each time (short)]
3
[One time (short)]
0
[Alarm]
F615
143
[Overtorque det.]
-
0
1
[Fault]
F616
143
[Overtorque level]
%
-
0 - 250
130
F618
143
[OvTorque det time]
s
-
0.0
- 10.0
0.5
F619
143
[Overtorque band]
%
-
0 - 100%
10
F621
130
[Run time alarm]
h
-
0.0 - 999.9 (0.1 = 1 hour, 100 = 1000 hours)
610.0
F626
139
[Overvoltage level]
%
1
[100 - 150% of nominal DC bus voltage]
140
0
[Alarm (0.6U)]
F627
138
[Undervolt detect.]
-
1
[Fault (0.6U)]
0
2
[Alarm (0.5U)]
0
[Disabled]
F632
137
[Mot overload memo]
-
0
1
[Enabled]
0
[Disabled]
F633
141
[Loss of VIA]
%
0
1-100
[Fault detection level]
1
[-10 to 10°C]
2
[11 to 20°C]
3
[21 to 30°C]
F634
144
[Amb. temp. alarm]
-
3
4
[31 to 40°C]
5
[41 to 50°C]
6
[51 to 60°C]
0
[No]
1
[Freewheel]
F644
142
[4-20 mA loss]
-
2
[Set speed]
0
3
[Keep speed]
4
[Ramp stop]
0
[Disabled]
F645
122
[Mot PTC selection]
-
1
[Enabled fault]
0
2
[Enabled alarm]
209
User Settings Tables
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
F646
122
[PTC resistor value]
-
100 - 9999
3000
F649
142
[4-20mA fallback sp]
Hz
-
0 - [Max frequency] (FH) Hz
0
0
[Disable]
F650
89
[Forced fire control]
-
1
[Enable forward]
0
2
[Enable Reverse]
0
[Enable transition ’’0->1’’]
F659
89
[Forced fire function]
-
1
[Enable level 1]
0
2
[Enable level 0]
0
[Negative slope]
F691
119
[AO slope]
-
1
1
[Positive slope]
F692
119
[Analog output bias]
%
-
0 - 100%
0
F694
119
[Freq. for AO = 0V]
Hz
-
0 - [Max frequency] (FH) Hz
0
F695
119
[Freq. for AO = 10V]
Hz
-
0 - [Max frequency] (FH) Hz
0
0
[Unlocked]
F700
68
[Parameter lock]
-
0
1
[Locked]
0
[%]
F701
130
[Unit value selection]
-
1
1
[Amp or Volt]
0
Frequency displayed in Hz
F702
131
[Customized freq val]
-
0.01 -
0
Conversion factor
200.0
0
[All]
F703
131
[Frequency convert.]
-
0
1
[PID only]
0
[Negative slope]
F705
131
[Custom freq. slope]
-
1
1
[Positive slope]
F706
131
[Customize unit bias]
Hz
-
0.00 - [Max frequency] (FH)
0.00
0
[Disable]
F707
87
[Loc. speed ref. step]
Hz
0.00
1
[Enable]
0
Disabled - 0.1 Hz steps
F708
130
[Display ref. resol.]
-
0
1 - 255
See formula on page 130
0
[Motor frequency]
1
[Reference]
2
[I Mot]
3
[Drive rated I]
4
[Drive therm state]
F710
130
[Displayed param.]
-
5
[Motor power]
0
6
[Int speed ref]
7
[Com data]
8
[Motor speed]
9
[Com count]
10
[Com count norm st.]
0
[Ramp stop]
F721
88
[Loc. mot stop mode]
-
0
1
[Freewheel]
0
[Enable]
F730
90
[Up/down key ref]
-
0
1
[Disable]
0
[Permitted memo]
F732
90
[Loc/rem key]
-
1
[Prohibited]
0
2
[Permitted no memo]
0
[Enable]
F733
90
[Run/stop key]
-
0
1
[Disable]
0
[Enable]
F734
90
[Priority stop]
-
0
1
[Disable]
0
[Disable]
F735
90
[HMI reset button]
-
1
1
[Enable]
0
[AUF displayed]
F738
68
[Quick menu AUF]
-
0
1
[AUF hidden]
0
[Disable]
Model
F748
130
[Power cons. memo]
-
depen-
1
[Enable]
dant
210
User Settings Tables
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
0
[1 kWh]
Model
1
[0.1 kWh]
F749
131
[Power cons. unit]
kWh
depen-
2
[0.01 kWh]
dant
3
[0.001 kWh]
0
[9600 bps]
F800
148
[Mdb RJ45 baud]
-
1
1
[19200 bps]
0
[No]
F801
148
[Mdb RJ45 parity]
-
1
[Even]
1
2
[Odd]
F802
148
[Modbus address]
-
-
0 - 247
1
0
Communication error detection disabled
F803
149
[Com. time out]
s
3
1-100
1 to 100 seconds
0
[RJ45]
F807
149
[Com channel choice]
-
1
1
[Open style]
0
[9600]
F820
149
[Mdb network baud]
-
1
1
[19200]
0
[No]
F821
149
[Mdb network parity]
s
1
[Even]
1
2
[Odd]
1
[Mdb RTU]
2
[Metasys N2]
F829
149
[Network protocol]
-
3
[Apogee P1]
4
[BACnet]
5
[LonWorks]
0
[Ramp stp (F/Cmod)]
1
[No active]
F851
149
[Com. fault setting]
-
2
[Ramp stop]
4
3
[Freewheel]
4
[Err5 or Err8]
1
[2 poles]
2
[4 poles]
3
[6 poles]
4
[8 poles]
F856
150
[Mot. poles (comm.)]
-
2
5
[10 poles]
6
[12 poles]
7
[14 poles]
8
[16 poles]
0
[No select]
1
[Command word 1]
2
[Command word 2]
F870
150
[Block write data 1]
-
3
[Frequency Setpoint]
0
4
[Relay command]
5
[FM command]
6
[Speed Setpoint]
0
[No select]
1
[Command word 1]
2
[Command word 2]
F871
150
[Block write data 2]
-
3
[Frequency Setpoint]
0
4
[Relay command]
5
[FM command]
6
[Speed Setpoint]
0
[No select]
1
[Command 1]
2
[Freq. out]
3
[Motor current]
4
[Output volt]
5
[Alarm info]
F875
150
[Block read data 1]
-
0
6
[PID feedback value]
7
[Input term. mon]
8
[Out term. mon]
9
[VIA monitor]
10
[VIB monitor]
11
[Mot speed mon.]
211
User Settings Tables
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
0
[No select]
1
[Command 1]
2
[Freq. out]
3
[Motor current]
4
[Output volt]
5
[Alarm info]
F876
150
[Block read data 2]
-
0
6
[PID feedback value]
7
[Input term. mon]
8
[Out term. mon]
9
[VIA monitor]
10
[VIB monitor]
11
[Mot speed mon.]
0
[No select]
1
[Status info]
2
[Freq. out]
3
[Motor current]
4
[Output volt]
5
[Alarm info]
F877
151
[Block read data 3]
-
0
6
[PID feedback value]
7
[Input term. mon]
8
[Out term. mon]
9
[VIA monitor]
10
[VIB monitor]
11
[Mot speed mon.]
0
[No select]
1
[Status info]
2
[Freq. out]
3
[Motor current]
4
[Output volt]
5
[Alarm info]
F878
151
[Block read data 4]
-
0
6
[PID feedback value]
7
[Input term. mon]
8
[Out term. mon]
9
[VIA monitor]
10
[VIB monitor]
11
[Mot speed mon.]
0
[No select]
1
[Status info]
2
[Freq. out]
3
[Motor current]
4
[Output volt]
5
[Alarm info]
F879
151
[Block read data 5]
-
0
6
[PID feedback value]
7
[Input term. mon]
8
[Out term. mon]
9
[VIA monitor]
10
[VIB monitor]
11
Mot speed mon.
F880
151
[Free ID parameter]
-
-
0 - 65535
0
F890
152
[Network adress]
-
-
0 - 65535
(1)
F891
152
[Network baud rate]
-
-
0 - 65535
(1)
F892
152
[Network time out]
-
-
20 - 600
(1)
F893
152
[Instance number H]
-
-
0 - 4194
(1)
F894
152
[Instance number L]
-
-
0 - 999
(1)
F895
152
[Max master]
-
-
0 - 127
(1)
F896
152
[Max info frames]
-
-
0 - 100
(1)
F912
85
[Autotune L q-axis]
-
-
0 - 650
10
F913
85
[Autotune L d-axis]
-
-
0 - 650
10
0
[0]
F914
86
[N-S direction]
-
0
1
[1]
212
User Settings Tables
Factory
User
Code
Page
Name
Unit
Adjustment Range / Function
Setting
Setting
0
[0]
1
[1]
F915
166
[PM mode selection]
-
2
[2]
3
3
[3]
4
[4]
F916
85
[PM Align cur. Level]
%
-
0 - 100
25
0
[0]
F917
86
[PM Max torq. Ctrl]
-
1
1
[1]
F918
86
[Cur. phase adjt]
-
-
-45 - 45.0
0.0
F920
86
[Position Adjust]
%
-
0 - 150
0
F921
85
[Init. Pos. Current]
%
-
10 - 150
0.0
F936
84
[Saliency Level]
-
-
0 - 2.55
0
(1) See table page 152.
213

 

 

 

 

 

 

 