Diesel engines D-260.1S3А, D-260.2S3А, D-260.4S3А. Manual - part 13

 

  Index      Engines     Diesel engines D-260.1S3А, D-260.2S3А, D-260.4S3А - service manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  11  12  13  14   ..

 

 

Diesel engines D-260.1S3А, D-260.2S3А, D-260.4S3А. Manual - part 13

 

 

 

Continuation of Table 10 

No 

 

Blink-
code 

R-code 

F

MI

 

S

PN

 

Fault type 

Fault description 

Fix method 

1-1-3 

Р0340  12 

636

 

Camshaft speed sensor signal  
absent. 

Camshaft speed sensor circuit fault. 

Check camshaft speed sensor 
condition and connections. 

того вала. 
Apply to service centre.  
 

 

Р0341  11 

Wrong camshaft speed sensor. 

1-1-4 

Р0016  7 

190

 

Crankshaft and camshaft speed sen-
sors signals mismatch. 
  

Crankshaft and camshaft speed sensors sig-
nals mismatch. 

 

Check camshaft and crank-
shaft speed sensors condition 
and connections.  
Apply to service centre.  
 

 

1-1-5 

Р0607  2 

523550

 

Deviation between electronic time 
processor time and central processor 
timer.  

Electronic time processor error. 

Apply to service centre.  
 

 

 

Continuation of Table 10 

No

 

Blink-
code 

R-code 

F

MI

 

S

PN

 

Fault type 

Fault description 

Fix method 

1-1-6 

Р1616  12 

970

 

Fault of “Watchdog” cylinders 
shutdown module path.  

Fault discovered at ECU initialization by 
the function of check of additional me-
thods for cylinder control power stages 
shutdown.  

 

  

Apply to service centre.  
 

Р1617  3 

Fault of path for cylinders shut-
down by power stage voltage ma-
ximal limit function.  

Р1618  4 

Fault of path for cylinders shut-
down by power stage voltage mi-
nimal limit function. 

1-2-1 

Р0617  3 

677

 

Power battery short circuit. 

Starter motor relay power stage fault.  

High voltage. 

Check starter motor condition 
and connections. 

Apply to service centre. 

Р0616  4 

Short circuit to ground.. 

1-2-1 

Р1638  3 

677

 

Short circuit to power battery. 

Starter motor relay power stage fault.  

Low voltage. 

Check starter motor condition 
and connections. 

Apply to service centre. 

Р1639  4 

Short circuit to ground.  
Load resistance absent. 

 

 

Continuation of Table 10 

No

 

Blink-
code 

R-code 

F

MI

 

S

PN

 

Fault type 

Fault description 

Fix method 

1-2-2 

Р2530  7 

1041

 

Terminal 50 is always closed 

Terminal 50 circuit fault. 

Check terminal 50  condition 
and connections. 
Apply to service centre. 

10 

1-2-3 

Р2533  12 

158

 

No signal from terminal 15. 

Terminal 15 circuit fault. 

Check terminal 15 condition 
and connections. 
Apply to service centre. 

11 

1-3-1 

Р0643  3 

079

 

Voltage beyond the set maximal 
limit. 

Sensors power supply 1 voltage fault.   

Apply to service centre. 

Р0642  4 

Voltage below the set minimal lim-
it. 

12 

1-3-1 

Р0653  3 

1080

 

Voltage beyond the set maximal 
limit.  

Sensors power supply 2 voltage fault.   

Apply to service centre. 

Р0652  4 

Voltage below the set minimal lim-
it. 

13 

1-3-1 

Р0699  3 

523601

 

Voltage beyond the set maximal 
limit.  

Sensors power supply 3 voltage fault.   

Apply to service centre. 

Р0698  4 

Voltage below the set minimal lim-
it. 

 

 

Continuation of Table 10 

No

 

Blink-
code 

R-code 

F

MI

 

S

PN

 

Fault type 

Fault description 

Fix method 
 

14 

1-3-1 

Р1640  3 

520235

 

Voltage beyond the set maximal 
limit.  

12V sensors voltage fault.  

Apply to service centre. 

Р1641  4 

Voltage below the set minimal lim-
it.  

15 

1-3-2 

Р0687  3 

1485

 

Short circuit to power battery. 

Main relay circuit 2 fault 

(control unit).   

Check the main relay condi-
tion and connections. 

Apply to service centre. 

Р0686  4 

Short circuit to ground.. 

16 

1-3-2 

Р160E  3 

2634

 

Short circuit to power battery. 

Main relay circuit 1 fault 

(control unit).   

Check the main relay condi-
tion and connections. 

Apply to service centre. 

17 

1-3-2 

Р160F  4 

2634

 

Short circuit to ground.. 

Main relay circuit 1 fault 

(control unit).   

Check the main relay condi-
tion and connections.  

Apply to service centre. 

18 

1-3-3 

Р0193  3 

157

 

Voltage beyond the set maximal 
limit.  

Rail fuel pressure sensor circuit fault. 

  

Check the Rail fuel pressure 
sensor condition and connec-
tions.  

Apply to service centre. 

Р0192  4 

Voltage below the set minimal 
limit.  

 

 

 

 

 

 

 

 

Content   ..  11  12  13  14   ..