HAC-188 < SYMPTOM DIAGNOSIS > [MANUAL AIR CONDITIONER] INSUFFICIENT COOLING INSUFFICIENT COOLING Description INFOID:0000000001070003 Symptom • Insufficient cooling Inspection procedure INFOID:0000000001070004 1. CHECK WITH A GAUGE OF ACR4 Connect ACR4 to the vehicle and perform the pressure inspection with the gauge. Is there refrigerant? YES >> GO TO 2. NO-1 >> Check for refrigerant leakages with the refrigerant leakage detecting fluorescent leak detector. (HR16DE/MR20DE) or (K9K). NO-2 >> GO TO 2 after repairing or replacing the parts according to the inspection results. 2. CHECK CHARGED REFRIGERANT AMOUNT 1. Connect ACR4 to the vehicle and discharge the refrigerant. 2. Recharge with the proper amount of refrigerant and perform the inspection with the refrigerant leakage (K9K). Is the inspection result normal? YES >> GO TO 3. NO >> Refill the refrigerant and repair or replace the parts according to the inspection results. 3. CHECK REFRIGERANT CYCLE PRESSURE Connect ACR4 to the vehicle and perform the performance test. Refer to PROCEDURE : Trouble Diagnosis For Unusual Pressure" NOSIS PROCEDURE : Trouble Diagnosis For Unusual Pressure" (K9K). Is the inspection result normal? YES >> GO TO 4. NO >> Perform the diagnosis with the gauge pressure. Refer to HA-114, "SYMPTOM DIAGNOSIS PRO- CEDURE : Trouble Diagnosis For Unusual Pressure" (HR16DE/MR20DE) or TOM DIAGNOSIS PROCEDURE : Trouble Diagnosis For Unusual Pressure" (K9K). 4. CHECK A/C COMPRESSOR BELT Check the A/C compressor belt. Refer to (MR20DE) or EM-259, "Inspection and Adjustment" (K9K). Is the inspection result normal? YES >> GO TO 5. NO >> Adjust or replace the A/C compressor belt. 5. CHECK AIR MIX DOOR CABLE Check the air mix door cable. Refer to HAC-126, "Description & Inspection" Is the inspection result normal? YES >> GO TO 6. NO >> Adjust or replace the air mix door cable. 6. CHECK AIR LEAKAGE FROM DUCT Check duct and nozzle, etc. of A/C system for air leakage. YES >> END. NO >> Repair or replace parts according to the inspection results. |