HAC-112 < SYMPTOM DIAGNOSIS > [AUTOMATIC AIR CONDITIONER] INSUFFICIENT HEATING NO >> Perform the diagnosis applicable to each output device. 7. PERFORM SELF-DIAGNOSIS STEP-5 Perform self-diagnosis STEP-5. Refer to HAC-27, "Diagnosis Description" . Is the inspection result normal? YES >> GO TO 8. NO >> Go to appropriate malfunctioning sensor circuit. Refer to HAC-27, "Diagnosis Description" . 8. CHECK AIR LEAKAGE FROM DUCT Check duct and nozzle, etc. of A/C system for air leakage. YES >> GO TO 9. NO >> Repair or replace parts according to the inspection results. 9. CHECK HEATER HOSE INSTALLATION CONDITION Check the heater hose installation condition visually (for twist, crush, etc.). Is the inspection result normal? YES >> GO TO 10. NO >> Repair or replace parts according to the inspection results. 10. CHECK TEMPERATURE OF HEATER HOSE 1. Check the temperature of inlet hose and outlet hose of heater core. 2. Check that the inlet side of heater core is hot and the outlet side is slightly lower than/almost equal to the CAUTION: The temperature inspection should be performed in a short time because the engine coolant tem- Is the inspection result normal? YES >> GO TO 11. NO >> Replace the heater core after performing the procedures after the cooling system inspection again. GO TO 1. 11. REPLACE HEATER CORE Replace the heater core. Refer to Are the symptoms solved? YES >> END. NO >> Perform the procedures after the cooling system inspection again. GO TO 1. |