P0101 MAF SENSOR EC-1335 < COMPONENT DIAGNOSIS > [K9K] C D E F G H I J K L M A EC N P O Is the inspection result normal? YES >> GO TO 6. NO >> GO TO 5. 5. DETECT MALFUNCTIONING PART Check the following. >> Repair open circuit or short to ground or short to power in harness or connectors. 6. CHECK MASS AIR FLOW SENSOR POWER SUPPLY CIRCUIT-II Check the voltage between mass air flow sensor harness connector and ground. Is the inspection result normal? YES >> GO TO 8. NO >> GO TO 7. 7. DETECT MALFUNCTIONING PART Check the following. >> Repair open circuit or short to ground or short to power in harness or connectors. 8. CHECK MASS AIR FLOW SENSOR GROUND CIRCUIT FOR OPEN AND SHORT 1. Check the continuity between mass air flow sensor harness connector and ECM harness connector. 2. Also check harness for short to ground and short to power. Is the inspection result normal? YES >> GO TO 10. NO >> GO TO 9. 9. DETECT MALFUNCTIONING PART Check the following. >> Repair open circuit or short to ground or short to power in harness or connectors. 10. CHECK MASS AIR FLOW SENSOR INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT 1. Check the continuity between mass air flow sensor harness connector and ECM harness connector. Mass air flow sensor Ground Voltage Connector Terminal E15 4 Ground Battery voltage Mass air flow sensor Ground Voltage Connector Terminal E15 5 Ground Approx. 5V Mass air flow sensor ECM Continuity Connector Terminal Connector Terminal E15 2 F85 30 Existed |