HO2S1 EC-1191 < COMPONENT DIAGNOSIS > [MR20DE (WITHOUT EURO-OBD)] C D E F G H I J K L M A EC N P O CAUTION: • Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one. • Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool and approved anti-seize lubricant. Is the inspection result normal? YES >> INSPECTION END NO >> GO TO 4 4. REPLACE HEATED OXYGEN SENSOR 1 Replace heated oxygen sensor 1. CAUTION: • Discard any heated oxygen sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one. • Before installing new oxygen sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner tool and approved anti-seize lubricant. >> INSPECTION END ECM ground Condition Voltage Connector Terminal F8 49 (HO2S1 signal) Ground Engine speed held at 2,000 • The voltage fluctuates between 0 to 0.3V and 0.6 to 1.0V more than 5 times within 10 seconds. • The maximum voltage is over 0.6V at least 1 time. → 0.6 - 1.0V → 0 - 0.3V 2 times: 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V → 0.6 - 1.0V → 0 - 0.3V |