ECM EC-963 < ECU DIAGNOSIS > [MR20DE (WITH EURO-OBD)] C D E F G H I J K L M A EC N P O • Sea level ° C (68 - 86 ° F) • Diagnosis is performed as quickly as possible under normal conditions. Under different conditions [For example: ambient air temperature other than 20 - 30 ° C (68 - 86 ° F)], diagno- sis may also be performed. Pattern 1: − 10 to 35 ° C (14 to 95 ° F) (where the voltage between the ECM terminal 46 and ground is 3.0 - 4.3V). • The engine must be operated at idle speed until the engine coolant temperature is greater than 70 ° C (158 ° F) (where the voltage between the ECM terminal 46 and ground is lower than 1.4V). • The engine is started at the fuel tank temperature of warmer than 0 ° C (32 ° F) (where the voltage between the ECM terminal 95 and ground is less than 4.1V). Pattern 2: In this case, the time required for diagnosis may be extended. Test Value and Test Limit INFOID:0000000000936977 The following is the information specified in Service $06 of SAE J1979. SRT item Self-diagnostic test item DTC Test value (GST display) Test limit TID CID CATALYST Three way catalyst function P0420 01H 01H Max. P0420 02H 81H Min. HO2S Heated oxygen sensor 1 P0133 09H 04H Max. P1143 0AH 84H Min. P1144 0BH 04H Max. P0132 0CH 04H Max. P0134 0DH 04H Max. Heated oxygen sensor 2 P0139 19H 86H Min. P1147 1AH 86H Min. P1146 1BH 06H Max. P0138 1CH 06H Max. HO2S HTR Heated oxygen sensor 1 heater P0135 29H 08H Max. 2AH 88H Min. Heated oxygen sensor 2 heater P0141 2DH 0AH Max. 2EH 8AH Min. |