|
|
|
Content .. 1916 1917 1918 1919 ..
WCS-18 < COMPONENT DIAGNOSIS > POWER SUPPLY AND GROUND CIRCUIT COMPONENT DIAGNOSIS POWER SUPPLY AND GROUND CIRCUIT COMBINATION METER COMBINATION METER : Diagnosis Procedure INFOID:0000000000936047 1. CHECK FUSE Check for blown fuses. Is the inspection result normal? YES >> GO TO 2. NO >> Be sure to eliminate cause of malfunction before installing new fuse. 2. CHECK POWER SUPPLY CIRCUIT Check voltage between combination meter harness connector terminals 1, 2 and ground. Is the inspection result normal? YES >> GO TO 3. NO >> Check harness between combination meter and fuse. 3. CHECK GROUND CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect combination meter connector. 3. Check continuity between combination meter harness connector terminals 3, 23 and ground. Is the inspection result normal? YES >> INSPECTION END NO >> Repair harness or connector. BCM (BODY CONTROL MODULE) BCM (BODY CONTROL MODULE) : Diagnosis Procedure INFOID:0000000001102067 1. CHECK FUSES AND FUSIBLE LINK Check that the following fuses and fusible link are not fusing. Is the fuse fusing? YES >> Replace the blown fuse or fusible link after repairing the affected circuit if a fuse or fusible link is blown. NO >> GO TO 2. 2. CHECK POWER SUPPLY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect BCM connectors. Battery power supply : 8 Ignition signal : 4 Terminal No. Signal name Ignition switch position Value (Approx.) 1 Battery power supply OFF Battery voltage 2 Ignition signal ON Battery voltage 3, 23 – Ground : Continuity should exist. Terminal No. Signal name Fuses and fusible link No. 41 Battery power supply 9 57 J 38 Ignition power supply 4 |