Content .. 1078 1079 1080 1081 ..
BUZZER (COMBINATION METER) DLK-399 < COMPONENT DIAGNOSIS > [WITH I-KEY & SUPER LOCK] C D E F G H I J L M A B DLK N O P BUZZER (COMBINATION METER) Description INFOID:0000000001115727 Performs operation method guide and warning with buzzer. Component Function Check INFOID:0000000001115728 1. CHECK FUNCTION With CONSULT-III Check the operation with “INSIDE BUZZER” in the Active test. Is the inspection result normal? Yes >> Warning buzzer in combination meter is OK. No >> Refer to DLK-399, "Diagnosis Procedure" Diagnosis Procedure INFOID:0000000001115729 1. CHECK BUZZER (COMBINATION METER) CIRCUIT WCS-20, "Component Function Check" . Is the inspection result normal? Yes >> Check intermittent incident. Refer to GI-39, "Intermittent Incident" . No >> Repair or replace buzzer (combination meter) circuit. Test item Condition INSIDE BUZZER :TAKE OUT Take away warning chime sounds :KNOB Ignition knob switch warning chime sounds :KEY Key warning chime sounds |