Content .. 1003 1004 1005 1006 ..
DOOR LOCK ACTUATOR DLK-99 < COMPONENT DIAGNOSIS > [WITH I-KEY, WITHOUT SUPER LOCK] C D E F G H I J L M A B DLK N O P REAR LH : Diagnosis Procedure INFOID:0000000001097245 1. CHECK OUTPUT SIGNAL 1. Turn ignition switch OFF. 2. Check voltage between BCM connector and ground. Is the inspection result normal? YES >> GO TO 6. NO >> GO TO 2. 2. CHECK DOOR LOCK ACTUATOR CIRCUIT 1. Disconnect BCM and rear door lock actuator (LH) connector. 2. Check continuity between BCM connector and rear door lock actuator (LH) connector. 3. Check continuity between BCM connector and ground. Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-39, "Intermittent Incident" . NO >> GO TO 3. 3. CHECK DOOR LOCK ACTUATOR CIRCUIT 1 1. Disconnect anti-hijack relay connector. 2. Check continuity between BCM connector and anti-hijack relay connector. 3. Check continuity between BCM connector and ground. Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace harness. 4. CHECK DOOR LOCK ACTUATOR CIRCUIT 2 Check continuity anti-hijack relay. Is the inspection result normal? Terminals Condition of door lock and unlock switch Voltage (V) (Approx.) (+) (–) BCM connector Terminal M67 56 Ground Lock 0 → Battery voltage → 0 54 Unlock 0 → Battery voltage → 0 BCM connector Terminal Door lock actuator connector Terminal Continuity M67 56 D85 3 Exists 54 2 BCM connector Terminal Ground Continuity M67 56 Does not exist 54 BCM connector Terminal Anti-hijack relay connector Terminal Continuity M67 56 M90 4 Exists BCM connector Terminal Ground Continuity M67 56 Does not exist Anti-hijack relay connector Terminal Continuity M90 4 3 Exists |