HEATING, VENTILATION AND AIR CONDITIONING (HVAC) 1A–125 Condition Possible cause Correction The fan dose not rotate at all — Refer to Chart A The fan dose not rotate in the — Refer to Chart B The fan dose not rotate in any mode — Refer to Chart C The fan dose not stop — Refer to Chart D Chart A: Fan Does Not Rotate At All Step Action Value(s) Yes No 1 Are the fuse No.C–19 and No.C–20 normal? — Go to Step 2 Replace the fuse 2 Are the relay No.B–36 and No.I–51 normal? — Go to Step 3 Replace the relay 3 Turn on the ignition switch (the engine is run). Is the battery voltage applied between the harness side — Go to Step 5 Go to Step 4 4 Repair an open circuit between terminal No.B5–1 and Is the action complete? — Go to Step 3 — 5 Is there continuity between the harness side connector — Go to Step 7 Go to Step 6 6 Repair an open circuit between terminal No.B5–2 and Is the action complete? — — — 7 Is the battery voltage applied between the harness side — Go to Step 8 Go to Step 9 8 Replace the blower motor. Is the action complete? — Verify repair — 9 Refer to chart B and C. Is the action complete? — Verify repair — |