Diesel engines D-260.1S3А, D-260.2S3А, D-260.4S3А. Manual - part 22

 

  Index      Engines     Diesel engines D-260.1S3А, D-260.2S3А, D-260.4S3А - service manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  20  21  22  23   ..

 

 

Diesel engines D-260.1S3А, D-260.2S3А, D-260.4S3А. Manual - part 22

 

 

 

Continuation of Table 10 

No

 

Blink-
code 

R-code 

F

MI

 

S

PN

 

Fault type 

Fault description 

Fix method 
 

126 

2-2-8 

P0856  2 

520199

 

Physically implausible request 
from Resistance Moment Control 
System Unit.  

Error of Resistance Moment Control Sys-
tem Unit.    

Check Resistance Moment 
Control System Unit condition 
and connection.   
Check CAN line connection to 
other CAN devices.  

Apply to service centre. 

127 

2-3-4 

Р0113  3 

172

 

Voltage beyond the set maximal 
limit.  

Fault of incoming air temperature sensor 
circuit in air mass consumption meter.  

Check sensor condition and 
connection.  

Apply to service centre. 

Р0112  4 

 

Voltage below the set minimal 
limit.  

128 

2-3-4 

Р0101  3 

132

 

Air mass consumption meter sig-
nal voltage beyond set limit.  

Error registered  by air mass consumption 
meter standard voltage initial deviation 
plausibility check function.  

Check air mass consumption 
meter condition and connection.  

Apply to service centre. 

Р0101  4 

Air mass consumption meter sig-
nal voltage below set limit.  

 

 

Continuation of Table 10 

No

 

Blink-
code 

R-code 

F

MI

 

S

PN

 

Fault type 

Fault description 

Fix method 
 

129 

2-3-4 

Р0103  3 

5201193

 

Air mass consumption meter coef-
ficient beyond set limit.  

Error registered by air mass consumption 
meter signal sensitivity deviation plausi-
bility check function.  

 
Check air mass consumption 
meter condition and connec-
tions.  

Apply to service centre. 

Р0102  4 

Air mass consumption meter coef-
ficient below set limit.  

130 

2-3-4 

P0103  3 

132

 

Mass air consumption registered 
beyond set limit.  

Error registered by air mass consumption 
meter signal boundary check function.  

Check air mass consumption 
meter condition and connec-
tions.  

Apply to service centre. 

P0102  4 

Registered mass air consumption 
below set limit.  

131 

2-3-5 

P0073  0 

171

 

Voltage beyond maximal physical 
limit.  

Error in ambient air temperature sensor 
circuit, physical limit check 

Check ambient air temperature 
sensor  condition and connec-
tion.  

Apply to service centre. 

P0072  1 

Voltage below minimal physical 
limit.  

 

 

Continuation of Table 10 

No

 

Blink-
code 

R-code 

F

MI

 

S

PN

 

Fault type 

Fault description 

Fix method 
 

132 

2-4-5 

P0116  2 

520198

 

Minimal cooling liquid tempera-
ture not achieved within the set 
time limit.  

Error registered by cooling liquid tempera-
ture sensor absolute plausibility check 
function.  

Check cooling liquid tempera-
ture sensor condition and con-
nection.  

Apply to service centre. 

133 

2-4-5 

P0116  2 

520198

 

Minimal rise of cooling liquid 
temperature not achieved within 
the set time limit.  

Error registered by cooling liquid tempera-
ture sensor dynamis plausibility check 
function.  

Check cooling liquid tempera-
ture sensor condition  and con-
nection.  

Apply to service centre. 

134 

2-6-1 

P0607  14 

520222

 

Electronic Unit retstart has taken 
place.  

Electronic Unit retstart by unknown rea-
son.  

Apply to service centre. 

135 

2-6-5 

P062F  4 

630

 

Error during the last reading  
operation.  

Fault  of Electrically Deletable Program-
mable Permanent Memory Device.  

Apply to service centre. 

P062F  12 

Error during the last record  
operation.  

P062F  2 

Deafualt value used.  

 

 

Continuation of Table 10 

No

 

Blink-
code 

R-code 

F

MI

 

S

PN

 

Fault type 

Fault description 

Fix method 
 

136 

3-1-3 

P0647  3 

1351

 

Short circuit to power battery. 

Fault in conditioner control power stage 
circuit.  

Check conditioner state and 
connection.  

Apply to service centre. 

P0646  4 

Short circuit to ground.. 

P0645  12 

No load resistance. 

P0645  2 

Excessive heat-up temperature. 

137 

3-2-1 

P0542  3 

729

 

Short circuit to power battery. 

Fault in air pre-heat power stage circuit.  

Check air pre-heat device con-
dition and connection.  

 Apply to service centre. 

P0541  4 

Short circuit to ground.. 

138 

3-2-2 

P0540  7 

676

 

Faulty multi-signal 

Air pre-heat permanently on.  

Check air pre-heat device con-
dition and connection.  

Apply to service centre.

 

 

 

 

 

 

 

 

 

Content   ..  20  21  22  23   ..