Document No:
Chapter –13 Technological Advancements
Version No: 1.0-d0
Date Issued: dd/mm/yyyy
Document Title: MANUAL MAINTENANCE FOR DIESEL LOCOMOTIVES
Revised 2013
Printed: 2015/03/08
Page 276 of 303
SN
Description
Use
Since
stand are unwieldy and prone to failure. To begin with, these have been replaced on WDM3Ds by
fastons of the type used on GM locos.
45.
Provision of dynamic braking on WDP2 locos: WDP2s have not been provided with DBRs
because of space constraints on this full-width, loco. In view of inherent advantages of dynamic
braking, it was decided to try out roof mounted DBRs within the loco MMD with natural cooling
46.
Modified LO and FO filer housings: In view of problem of leakage of lube oil from the bottom
of LO filter housing due to development of crack of welding between the shell and the bottom
plate, the housing has redesigned with dish type bottom with change over from fillet weld to butt
weld joint. RDSO had issued Instruction Bulletin No. MP.IB.EN.07.52.09 for change of design
flat bottom to dish bottom type LO filter assembly.
47.
Modified low maintenance brake system piping: It has been decided to implement good
features of the GM loco brake system. The improvements would include features like elimination
of mitre joints & modification to forged unions/elbows to eliminate the problems related with
poor welds and joints, reduced threaded joints, relocation of reservoirs, improved clamping etc.
and the overall design should improve reliability as well as maintainability.
48.
Modified air duct boot (without reinforced fabric): Air duct boot is, at present, made from
rubber reinforced with fabric. There are persistent quality problems with the present design as the
dimensional control of the product is not satisfactory. Air duct Boot without using reinforced
fabric has been developed. Air duct boot without reinforced fabric has been developed as per
specification no. MP.0.2400.22 (Rev-01), 2006 issued.
49.
Thermal insulation for exhaust manifold: Thermal Insulation for Exhaust Manifold was first
used on 3100 hp, full-width, dual cab, WDP2 loco primarily with the purpose of reducing
temperatures in the engine room thus making the loco more user-friendly.
50.
Improved high-cap SS slip ring alternator- 10102 DW : This type of alternator was developed
by BHEL in association with RDSO/DLW with increased conductor cross section, less steel slip
ring, external neutral connection and strengthened gear case. These alternators are regularly being
fitted on all new builds at DLW.
51.
Improved cable conduiting, sleeving and heat shrinkable tubings : The cable conduits used on
GM locos, both flexible and rigid, employ end fittings, which totally obviate the possibility of any
oil or dirt ingress inside the conduits. The flexible conduit covering material is of an improved
elastomer.
52.
Modification to WDP2 bogies: Difficulty is faced by DLW and Railways during fitment of
guide link on WDP2 locos. The bogies have other features which render it poorer in respect of
maintainability and reliability like breakage of secondary springs. The matter was studied by
DLW/RDSO in detail and a modified design has been developed by RDSO, incorporating features
from ABB bogie.
53.
Notch separation on E type controls: The existing E type controls are not amenable to notch-
wise adjustment of power. Since large-scale deployment of microprocessor based systems is
likely to take some more time, it was decided to take a project to upgrade the E type system itself
for incorporation of notch wise adjustments.
54.
GM type headlight, cab, exterior and engine room lights: These fittings for GM loco, except
the headlight lamp, have been indigenized and it is proposed to introduce the same on ALCO
locos also.
55.
Modified LO Piping: For improving reliability and maintainability, modified lube oil piping has
been introduced on WDG2 locos. The piping had many features, which have been adopted
although some features like bellow couplings did not succeed and pressure drop problem was not
solved.
56.
Modified under frame for WDG2 locos: Following major complaints existed on the under
frame of WDG2 locos:
1. Higher vibrations in the radiator room of WDG2s, which in turn arises as the floor is not
secured to longitudinal member. The arrangement of stiffeners required to be modified
2.Common engine & TA trough remains filled with leak off oil and the air drawn by the
alternator/FTMB carries this oil and the same required separating out by a partition
3.Oil enters into the resilient pad of TM no. 4 causing frequent problems on pad as well as TM
cables despite undertaking modifications suggested by DLW. The drain of the sump is an L pipe,
which gets choked and oil drops directly on TM no. 4. The system needed to be modified by
eliminating the L pipe with one sloped tray and a vertical discharge pipe covering all the drain
pipes of A/C sump & engine trough secured to the under frame.
4. Inadequate air outlets for alternator, requiring the outlet through the frame to be enlarged.