Joints shall be filled as soon as practical after compaction, before the termination of each work day, 
before acceptance of the day’s work, and before construction traffic is allowed.  

Dimensional accuracy, uniformity of joint games, alignment, and squareness of the paver installation 
shall  be  checked  by  the  Contractor  after  laying  the  first  3  rows  of  blocks  and  at  regular  intervals 
thereafter. If joints begin to open, the blocks shall be knocked together using a rubber or wooden 
mallet. 

Completed sidewalks shall meet the requirements of the following tolerances, or the Contractor shall 
remove and replace, at the Contractor

’s expense, failing areas:  

a.  Surface level shall be ±5 mm of the design level

b.  Maximum deviation within the compacted surface shall be 3 mm or less, as measured with a

3 m straightedge 

c.  Level of any 2 adjacent blocks shall not differ by more than 1 mm

Exposed paver surfaces shall be washed clean after installation. Prior to final acceptance, any loose, 
chipped, broken, stained, or otherwise damaged pavers shall be removed and replaced. New units 
that match adjoining units shall be provided and installed by the Contractor in the same manner as 
the original units with the same joint treatment. 

7.6.7 Tile Sidewalks 

Unless  otherwise  shown  or  specified,  tile  installation  for  sidewalks  shall  comply  with  applicable 
requirements  of  ANSI  A  108/A  118/A  136.1  and  recommendations  of  the  TCNA  Handbook  for 
Ceramic  Tile  Installation,  as  well  as  the  manufacturer's  instructions  for  the  installation  of  each 
material required. Tiles shall be furnished and installed as shown on the Contract plans to the lines 
and  grades  shown  on  the  Contract  plans,  as  approved  by  the  Engineer.  Colours,  patterns,  and 
mosaics of quarry tile shall be as shown on the Contract plans.  

Tile sidewalks shall be installed by the Contractor with at least 3 years experience in the installation 
of materials comparable to those specified for the project. 

Prior  to  installation  of  tile  sidewalks,  the  Contractor  shall  submit the following  to  the  Engineer  for 
approval:  

  Evidence of the Contractor

’s 3 years of experience, including contact information for the owner

of each project 

  Three samples of each type, class, and colour of tile for each form of construction and finish

  Detailed shop drawings showing proposed widths, lines, grades, accesses, layout of all field

tiles, trim shapes, jointing patterns, and any other details necessary to properly construct the 
work.  Contractor  shall  provide  scale  details  of  expansion  joints,  control  joints,  special  tiles, 
frame and service abutments. 

  Test panels, measuring not less than 300 mm on a side, shall consist of a plywood backing

with tile grouted as required for installation in the works using materials indicated for the work. 
Engineer

’s approval shall be for colour, pattern, texture and joint width only. Compliance with 

all other requirements is the exclusive responsibility of the Contractor  

No tiles shall be fabricated nor delivered before approval of  shop drawings. Laying tile sidewalks 
shall be as follows, unless otherwise directed by the Engineer:  

a.  Subgrade shall be prepared in accordance with Article 7.6.3.17.6.3.2 and the Contractor shall

ensure that: 

1.  Substrates for setting tile are firm, dry, and clean and free from oil or waxy films or curing

compounds 

2.  Grounds, anchors, recessed frames, electrical and mechanical units of work, and similar

items located in or behind tile have been completed before installing tile 

C

ONSTRUCTION

 

 

b.  Tiles shall be soaked in water a minimum of 30 minutes prior to installation  

c.  Base shall consist of the following:  

1.  For  quarry  tiles,  bases  shall  be  a  100  mm  thick  base  slab  of  Class  C15/20  concrete 

complying  with  the  requirements  of  Section  4.3  of  Chapter  4,  Concrete  Works,  or  as 
otherwise shown in the Contract plans 

2.  For precast tile blocks, bases shall be a 50 mm thick layer of clean coarse sand, 100 % 

passing a 6-mm sieve, 0 % to 35 % passing a 0.300 mm sieve and 0 % to 10 % passing a 
0.150 mm sieve, shall be spread with water added and compacted to obtain the required 
grades before placing the precast concrete blocks 

d.  Quarry tiles shall be installed in accordance with ANSI A 108.1, except that the mortar bed 

shall be 40 mm thick, as indicated on the Contract plans and shall be Class M3 mortar with a 
latex additive that meets the requirements of Article 4.3.10.4 of Chapter 4, Concrete Works  

e.  Mortar  bed shall not lay longer than 45 minutes or  until mortar  begins to set  before placing 

tiles. 

f.  Tile shall be laid symmetrically starting at the centre of area and finishing with equally cut rows 

on the sides  

g.  Freshly placed tiles shall be damp cured for a minimum 72 hours prior to grouting  

h.  Pointing and grouting material shall be the same as for the mortar bed  

If necessary, the Contractor may etch substrate with 10 % solution of muriatic acid, if necessary to 
remove curing compounds or other substances that would interfere with the proper bond of specified 
mortar for tiles. To remove all traces of acid and to seal the substrate with sealer, as recommended 
by the manufacture, the Contractor shall rinse the tiles with water. 

Tile work shall be laid-out in the pattern and trim shapes as shown on the Contract plans. Tiles shall 
form a complete covering without interruptions, except for control and expansion joints as shown on 
the  Contract  plans  and  as  requ

ired  to  comply  with  the  manufacturer’s  instructions.  Edges  and 

corners shall be neat without disruption of pattern or joint alignments. Joint widths shall be uniform.  

Where required, tiles shall be cut with approved power saws. Tiles with jagged or flaked edges shall 
not  be  installed.  Cutting and  drilling  of  tile  shall  not  mar the  surface.  Cut tile  edges  abutting trim, 
finish, or built-in items shall be carefully ground to create straight, aligned joints. Tile shall fit closely 
around penetrations. 

Control or expansion joints shall be provided where shown, or required by ANSI or TCNA standards, 
or by job condition for proper workmanship. This process shall be as follows:  

1.  Install removable divider strip of proper width and depth to include tile and bed  

2.  Grout tiles and properly cure the work  

3.  Remove  strips  and  install  joint  fillers  and  sealants  of  the  type  recommended  by  the  tiling 

manufacturer 

Upon completion of placement and grouting, tile surfaces shall be cleaned so they are free of foreign 
matter. Grout residue shall be removed from tile immediately. Unglazed tiles may be cleaned with 
acid solutions only when permitted by the tile and grout manufacturer's printed instructions, but no 
sooner than 14 days after installation. Metal surfaces, cast iron, and vitreous plumbing fixtures shall 
be protected from the effects of acid cleaning. Surfaces shall be flushed with clean water before and 
after cleaning. 

Temporary  protective  coatings  shall  be  removed  by  methods  recommended  by  the  coating 
manufacturer  and  that  are  acceptable  to  the  brick  and  grout  manufacturer.  Coating  shall  be 
discarded in a manner that prevents clogging drains. 

Finished installations shall be clean and free of cracked, chipped, broken, unbounded, and otherwise 
defective tile work. Final protection and conditions meet the requirements of the manufacturer and 
installer to ensure tile is without damage or deterioration at the time of substantial completion. 

When  recommended  by  tile  manufacturer,  the  Contractor  shall  apply  a  protective  coat  of  neutral 
protective  cleaner  to  completed  tile  walls  and  floors.  Installed  tile  work  shall  be  protected  by  the 
Contractor with kraft paper or other heavy covering during the construction period to prevent staining, 
damage, and wear. Foot and wheel traffic on tiled floors shall be prohibited by the Contractor for at 
least 7 days after grouting is completed. 

7.6.8 Architectural Concrete Sidewalks 

Prior  to  installation,  the  Contractor  shall  prepare  a  1-m  by  1-m  test  panel,  75  mm  thick,  of  each 
colour, pattern, and texture required for the Engineer

’s approval. 

Foundations shall be prepared per Article 7.6.3.17.6.3.2 and as shown on the Contract plans. Screed 
concrete shall be placed to the proper grade and wood-float to a uniform surface per Article 7.6.4.1. 
Colourant  shall  be  applied  by  the  Contractor 

in  accordance  with  the  manufacturer’s 

recommendations. Stain or colourant shall meet the requirements of Section 7.8. 

If a dry-shake colour hardener is used, the Contractor shall apply it evenly to the plastic concrete 
surface per the manufacturer’s directions and using at least 30 kg per 10 m

2

.  

Colours shall be applied in two separate applications and the Contractor shall wood-float the surface 
after each application. Trowelling shall occur only after the final floating.  

Dyes with a repetitive pattern shall be placed on the concrete surface and hand-tamped to create 
the required texture or imprint shown on the Contract plans. 

Coloured curing and f

inishing compounds shall be applied in accordance with the manufacturer’s 

directions. 

7.7  Fencing 

7.7.1 Description 

This work furnishes, installs, repairs, and replaces fences and gates, complete with hardware and 
appurtenances,  as  shown  on  the  Contract  plans,  as  specified  herein,  and  as  approved  by  the 
Engineer. Types and height of fencing shall be shown on the Contract plans. These types include 
the following:  

  Chain-link fence, including vinyl coated chain link.

  Glare screen

  Wire fence, which may be barbed wire or include woven wire

  Temporary fence

  Sand fence

Chain-link and wire fence are typically used as animal/pedestrian barriers along highway right-of-
ways.  Wire fence is more generally used for right-of-way fencing in rural areas. Chain link may be 
also used for security or vandal protection around public restricted areas. 

Glare  screens  typically  consist  of  manufactured  units  and  may  be  of  two  different  general  types. 
Type  1  is  a  vertical  blade  type  usually  mounted  to  the  tops  of  traffic  barriers  to  limit  glare  from 
oncoming traffic headlights, used for both permanent and temporary detour applications.  Type 2 are 
usually  constructed  of  a  small  pattern  sized  diamond-woven  wire  mesh  fence  or  using  chain-link 
fencing  with  interlocked  vertical  slats,  manufactured  from  aluminium-,  galvanised-,  or  aluminium-
coated steel that is fabricated and placed to reduce glare from headlights of opposing traffic or other 
adjacent  light  sources.  Type  2  glare  screens  can  be  installed  for  both  permanent  and  temporary 

applications, and are often used as a combination glare screen and visual barrier for traffic along 
work zones. 

Sand fences may be of two general types.  Type 1 is a wire fence similar to the wire fence specified 
in Article 7.7.3.4, except specifically modified to be used in rural areas as a camel fence.  Type 2 as 
specified herein, is a sand trapping fence composed of manufactured units consisting of twisted wire 
pairs with interwoven wooden slats specifically designed to trap and help protect the roadway from 
drifting, windblown sand.  

7.7.2 Materials 

All material used in the construction of fences and gates shall be new. Materials shall be durable 
and impact resistant, meeting the requirements specified herein, as shown on the Contract plans, or 
as may be described in the Particular Specifications and as approved by the Engineer. Iron or steel 
material shall be galvanised, unless specified otherwise. Material upon which serious abrasions of 
galvanising occurs shall not be acceptable.  All fence materials, per each type and application, shall 
be provided from a single manufacture as approved by the Engineer. 

All materials for the various types of fencing shall comply with the specified requirement of  Table 
7-34,
 including coating class, style, fabric, fittings, and hardware. Where there is a conflict between
these Specifications and the referenced specification, the requirements of these Specifications shall 
govern.  

Table 7-34: Materials requirements for fencing installations 

Material 

Requirement 

Barbed wire 

AASHTO M 280 

Tension wire 

AASHTO M 181 

Steel woven fence wire 

ASTM A116,

 

AASHTO M 181,

 

AASHTO M 279 

Fence fittings 

ASTM F626 or AASHTO M 232M 

Fence posts and framework steel sections 
Fence  post  and  framework  steel  strengths 
and coatings 

ASTM A702, AASHTO M 181 
ASTM F1043, ASTM F1083 

Sampling of pipe posts for galvanizing 

ASTM A53M 

PVC shall mean polyvinyl chloride. GMS shall mean galvanised mild steel. 

Approval  of  fence  material  shall  be  by manufacturer’s  certificate of  compliance,  submitted  by  the 
Contractor. This submittal shall include the following information for Engineer

’s approval:  

 

Manufacturer’s name

  Product name and description

 

Manufacturer’s technical data

  Storage instructions

  Installation instructions

Contractor shall also provide the following to the Engineer: 

a.  Shop drawings showing a complete layout plan with posts, bracings, gate, and detail drawings

for all connections 

b.  Mock-ups, as requested by the Engineer, that includes, at a minimum, a 2-m-length with typical

gate hardware and connections 

Samples shall be supplied by the Contractor, as requested by the Engineer, and shall include, at a 
minimum, the following: 

1.  Mesh measuring 300 mm by 300 mm

2.  Line wire measuring 300 mm long

3.  Tying wire measuring 300 mm long

4.  Stirrup wire measuring 300 mm long

5.  Barbed wire measuring 300 mm long

6.  Fence fittings measuring 300 mm long

7.  Post and brace of each type

Manufacturer  shall  be  a  company  specialised  in  production  of  the  fencing  type  required,  with 
minimum of 5 years experience. 

7.7.2.1 

 Chain-link Fence 

a.  Post Material for Chain-link Fence

Except as noted otherwise, base metal for the manufacturing of posts and braces shall comply with 
the requirements of AASHTO M 181, Type I zinc-coated steel, Grades 1 or 2; and shall include all 
round and roll-formed material, including brace rails, top rails, line posts, brace posts, end posts, 
corner posts, and pull posts 

— except that the carbon content of steel posts shall not be more than 

0.4 %. Steel made by the oxygen furnace process will be acceptable.  

Grade 1 post material shall conform to the weight per linear foot, minimum wall thickness and detail 
requirements  of  ASTM  F1043.  Grade  1  post  material  that  exceeds  the  maximum  wall  thickness 
requirement  of  ASTM  F1043  may  be  accepted,  provided  it  does  not  interfere  with  the  proper 
construction of the fence.  

Grade  2  post  material  shall  meet  the  organic  exterior  coatings  requirements  of  AASHTO  M  181, 
Section  33;  and  the  additional  requirement  that  the  interior  coated  surface  shall  be  capable  of 
resisting 300 hours of exposure to salt fog with a maximum of 5 % red rust when tested in accordance 
with ASTM B117. 

Round post material shall be either Grade 1 or 2. 

Roll-formed  post  material  shall  be  Grade  1.  Roll-formed  end,  corner,  and  pull  posts  shall  have 
integral fastening loops to connect to the fabric for the full length of each post. Top rails and brace 
rails shall be open, rectangular sections with internal flanges as shown in ASTM F1043. 

Posts  and  braces  shall  additionally  comply  with  the  following  requirements,  unless  otherwise 
indicated on the Contract plans.  

Table 7-35: Chain-link post requirements 

Location 

Type 

Minimum size of the 

greatest dimension 

(mm) 

Minimum wt per linear 

metre (kgs) 

End, corner, pull, and gate 
posts 

Pipe 

60.3 OD 

5.43 

Line posts 

Pipe 

48.3 OD 

4.05 

Braces (struts) 

Pipe 

42.2 OD 

3.38 

OD = outside diameter 

Post-types used shall be the same on any one project. 

Posts shall have provisions to securely hold the top tension wire in position and allow for removal 
and replacement of a post without damaging the top tension wire. Tubular posts shall be fitted with 
rain-proof tops.  

Extension arms, stretcher bars, and other required fittings and hardware shall be steel or malleable 
iron, or wrought iron, and shall be hot-dipped galvanised.  

b.  Post Caps for Chain-link Fence

Malleable iron, or plastic, post caps designed to exclude all moisture shall be provided for each post. 
If the Contract plans show barbed wire, the Contractor shall furnish barbed wire support arms integral 
with the post caps. If a top rail is shown on the Contract plans, the Contractor shall furnish post caps 
with an opening for the top rail. Post caps must have a 50 mm skirt. 

c.  Chain-link Fence Fabric

Chain-link fence fabric shall consist of galvanised steel wire that complies with AASHTO M 181 and 
as shown on the Contract plans. Base metal shall be hot-dipped galvanised steel wire. Wire used in 
the manufacture of the fabric shall be 4.88 mm for all fence fabric. Wire shall be woven into 50 mm, 
±2 mm, diamond mesh. Width, top, and bottom finishes of the fabric shall be as specified in AASHTO 
M 181. 

Tie wires and post clips shall be at least 3.76 mm galvanised steel. 

Turnbuckles and truss tighteners shall be fabricated of commercial quality steel, malleable iron, or 
wrought iron, and shall be hot-dipped galvanised. Truss tighteners shall have a strap thickness of 
not less than 6 mm.  

Portland cement concrete shall be used for metal post, brace foundations, and deadmen; and shall 
comply  with  the  requirements  of  Section  4.3.1  of  Chapter  4,  Concrete  Works,  for  Class  C20/20 
concrete.  

d.  Gates for Chain-link Fence

Gates shall be of the sizes shown on the Contract plans, and gates wider than 2.45 m shall have a 
vertical member installed at the midway point of the gate. 

Gate frames shall be constructed of not less than 38 mm internal diameter, hot-dipped galvanised 
pipe  conforming  to  AASHTO  M  181  Type  I,  Grades  1  or  2.  Corners  of  the  gate  frame  shall  be 
fastened  together  and  reinforced  with  a  malleable  iron  or  pressed-steel  fitting  designed  for  the 
purpose.  They  may  also  be  welded  in  conformance  to  the  requirements  of  Sections  23.4.11  and 
23.6.10  of  Chapter  23,  Steel  Structures.  Paint  shall  be  applied  in  conformance  to  the  applicable 
requirements of Chapter 24, Painting.  

Each gate shall be furnished complete with necessary hinges, latch, and a drop bar locking device 
designed  for  the  type  of  gate  posts  and  gate  used  on the  project. Gates  shall  have  positive  type 
latching  devices  with  provisions  for  padlocking.  Hinges,  latches,  and  locking  devices  shall  be 
galvanised. Locks shall be supplied for each gate.  Three sets of keys shall be provided for all locks. 

Gates fabricated from round sections of pipe of the size and weight shown on the  Contract plans 
shall  be  provided  by  the  Contractor.  These  materials  shall  meet  ASTM  F1083  for  all  gate  pipes. 
Chain-link fence fabric for filling the gate frame shall meet the requirements of Sub-article c, of Article 
7.7.2.1, for the fence type being furnished. Cross trussing shall consist of 9-mm steel adjustable rods 
that have been galvanised. Chain-link fence fabric specified for the fence shall be attached to the 
gate frame by the use of stretcher bars and the tie wires, as specified for fence construction. Suitable 
tension connectors shall be spaced at approximately 300 mm intervals. For each gate, the Contractor 
shall include the following:  

1.  Corner  and tee fittings of malleable iron or pressed steel with means for attaching diagonal

bracing members 

2.  Hinges of malleable iron allowing a full 180° swing, easily operated by one person

3.  Ball-and-socket-type bottom  hinges that do not twist or turn from the action of  the gate and

prevent the closed gate from being lifted off the hinges 

4.  A positive stop that prevents any portion of the gate from swinging over an adjacent traffic lane.

5.  At least 2 steel, or malleable iron, hinges not less than 80 mm in width to hang the gate, so

designed as to securely clasp to the gate post and permit the gate to be swung back against 
the fence 

6.  A malleable iron pulley system for roll-type gates, when required.

7.  Diagonal braces consisting of 9-mm-diameter cable with turnbuckles, 2 to each gate frame;

and, for vehicle gates, a vertical pipe brace of the size and weight shown on the Contract plans 
at the centre of each gate leaf 

8.  Latches of malleable iron or steel for single gates with a single-fork latch and padlock eye that

will keep the gate closed 

9.  Heavy-duty padlocks acceptable to the Engineer and master-keyed. Padlocks shall be a 51

mm,  Type  EPC,  5-pin  tumbler  mechanism,  brass  or  bronze,  solid  case,  with  chain,  unless 
otherwise directed by the Engineer 

10.  Two fork latches mounted on a centre plunger rod with a padlock eye for double-leaf gates

11.  Holdbacks for each leaf of vehicular gates, with a semi-automatic holdback catch anchored

at least 300 mm into a 300 mm diameter by 600-mm-deep concrete footing and a malleable 
iron centre rest, designed to receive the plunger rod anchored as shown on the Contract plans 
for all double-leaf gates 

Gate frames constructed of steel sections, other than pipe, that are fabricated in such a manner as 
to form a gate of equal or better rigidity may be used, provided they are approved by the Engineer.  

e.  Tension Wire for Chain-link Fence

Tension  wire  shall  meet  the  requirements  of  AASHTO  M  181.  Tension  wire  galvanising  shall  be 
Class 1. 

f.  Fittings and Hardware for Chain-link Fence

Except where indicated, fittings shall be malleable cast iron or pressed steel and shall conform to 
the  requirements  of  ASTM  F626  or  AASHTO  M  232M,  whichever  is  applicable.  Fittings  for  any 
particular fence shall be those furnished by the manufacturer of the fence. 

Tension  truss  rods  shall  be  9.5  mm  round  galvanised  rods  with  drop-forged  turnbuckles  or  other 
approved  type  of  adjustment.  Truss  tighteners  shall  have  a  strap  thickness  of  at  least  6.35  mm. 
Couplings for tubular sections shall be outside sleeve type and shall be at least 150 mm long.  

Eye-bolts for attaching tension wire shall be 9.5 mm diameter and of sufficient length to fasten to the 
type of post being used. Tension bars shall be 4.76 mm by 19 mm nominal and cross sectional area 
shall be 90 mm

2

,

 ±5 %.  

Hog rings shall be 2.68 mm galvanised steel wire. Tie wire shall be 3.76 mm galvanised steel wire 
or 3.76 mm aluminium wire meeting the requirements of ASTM F626. 

Structural bars, stretcher bar bands, post caps, and miscellaneous hardware shall be fabricated from 
commercial quality steel and shall be zinc-coated in accordance with the requirements of AASHTO 
M 111M. Stretcher bars shall be 4.76 mm by 19 mm steel flat bars. Stretcher bar bands shall be 3.2 
mm by 25.4 mm preformed steel bands. 

Barbed  wire,  for  use  with  chain-link  fence,  shall  conform  to  the  requirements  of  Sub-article  e,  of 
Article 7.7.2.3, of these specifications. Barbed wire support arms shall be of the type shown on the 
Contract  plans,  shall  be  fabricated  from  commercial  quality  steel,  and  shall  be  zinc-coated  in 
accordance with the requirements of AASHTO M 111M. Barbed wire shall be as specified on the 
Contract  plans,  typically  3  strands  of  twisted  2.51  mm  barbed  wire  with  4-point,  2.03  mm  barbs 

C

ONSTRUCTION

 

 

spaced  approximately  125  mm,  conforming  to  ASTM  A121.  Support  arms  typically  extend  at  an 
angle of 45° from vertical, with clips for attaching 3 strands of barbed wire to each support arm and 
sufficient strength to support a 90 kg weight applied at the outer strand. 

Contractor shall install grounding rods consisting of copper-clad steel rods at least 2.5 m long, with 
a minimum diameter of 16 mm, or other ground rod approved by the Engineer.  

All  necessary  quantities of  fittings  and  fasteners shall  by  furnished  by the  Contractor  in  sufficient 
quantities to erect all fencing materials in a proper manner. Fittings for posts shall be form-pressed 
or rolled steel, forged steel, malleable iron or wrought iron of good commercial quality, and spaced 
as shown on the Contract plans. 

g.  Chain-link Fence Coatings 

Where shown on the Contract plans, or required in the Particular Specifications, posts, gate frames, 
rails,  bracings,  clamps,  accessories  and  similar  materials  shall  have  a  vinyl  coating  thickness  of 
0.254 mm to 0.356 mm.  

Fabric shall have a vinyl coating thickness over the galvanised substrate as per AASHTO M 181. 

Vinyl coating shall be continuously extruded, not sprayed or dipped, over the galvanised steel wire 
by  the  thermal  extrusion  process  under  352  kg/cm

2

  (34  MPa)  pressure  to  ensure  a  dense  and 

impervious covering free of voids, having a smooth and lustrous surface appearance.  

Wire shall be vinyl-clad before weaving and shall be free and flexible at all joints. 

Plasticised PVC with a low temperature -20° C, consisting of plasticiser with no fillers, extenders, or 
extraneous matter other than the necessary stabilisers and pigments shall be used. Colours shall be 
stabilised and have a light fastness that shall withstand a minimum Weather-O-Meter exposure of 
10,000 hours without any deterioration per ASTM D1499, E 42, Type E. 

In addition to the requirements above, Vinyl-clad wire shall meet the material requirements of Table 
7-36. 
 

Table 7-36: Requirements for vinyl coating for chain-link wire 

Property 

Requirement 

Accelerated aging test: 10,000 hours at 62° C 

No cracking or peeling 

Character 

Self-extinguishing 

Insulation 

12,000 volts 

Tensile strength 

190 kg/cm

2

 

Elongation 

275 % 

Specific gravity 

1.30 maximum 

Hardness 

At least Durometer A-90, ±5 

Abrasion resistance 

High 

U.L. Test for abrasion at 120° C under 500 g load  15 % maximum deformation  

Compression cut through (Bell Laboratory Test)  105.5 kg/cm

Vinyl  coatings  shall,  in  addition, resist  attack  from  prolonged  exposure  to  dilute  solutions  of most 
common mineral acids, sea water, and dilute solutions of most salts and alkalis. 

Pipe coating materials shall meet the material requirements of Table 7-37. 

Table 7-37: Requirements for pipe coating materials 

Property 

Requirement 

Specific gravity 

1.32 maximum 

Tensile strength 

105.5 kg/cm

2

 minimum 

Elongation 

200 % 

Tear strength 

381 microns = 2.4 kg 

Hardness of coating 

At least 80 Shore A Durometer, ±v5 

Dielectric strength 

1,000 volts per mil 

Volume resistivity 

2.0 ohm/cm by 1012 ohm/cm 

Brittle temperature 

-20° C (film)

Water absorption  

at 25°C, one week 

at 94°C, 2 hours  

0.70 % maximum 

0.95 % maximum 

Resin formulation shall meet the standard 3,000-
hour Weather-O-Meter requirement 

No cracking, blistering, or loss of adhesion 

Impact resistance test, Gardner test method 

185 cm/kg minimum 

Certified abrasion resistance: withstand at least 

10-minute blast, at 5.6 kg/cm

2

, at 305 mm, at 25°

C with S230 shot at an impingement angle of 90 
degrees 

Steel substrate shall not be exposed 

Salt  spray  test  (Federal  Test  standard  141

Method 6061) 

For  scored  samples  after  exposure  of  1,000 
hours 

10,000  hours  minimum  with  no  perceptive 
deterioration to  coating or  evidence  of  metal 
corrosion for unscored samples.  

Undercutting shall not exceed 5 mm 

Prolonged exposure at 24° C to fuses 

Exhibit chemical resistance 

Resist attach from prolonged exposure to dilute 
solutions of mineral acids, sea water, and most 
salts and alkaline 

All damaged areas of the coating shall be repaired in accordance with the coating 

manufacturer’s 

instructions. 

All fasteners, including nuts, bolts, washers, shall be stainless steel of Type 316 or A4. 

All hardware, including latches and hinges, shall be GMS. 

h.  Motorised Gates and Accessories

1.  Horizontal Sliding Type

Gates  shall  have  a  minimum  clear  width  of  7.3 m  and  1.0  m  for  vehicular  and  pedestrian 
entrances, respectively, and a height to match the fence height as shown on the  Contract 
plans. 

Frame, verticals, and bracings shall be of mild steel (MS) hollow sections, as detailed in the 
Contract plans. After fabrication, MS sections, accessories, and other components shall be 
hot-dipped  galvanised.  Finished  fabricated  products  shall  be  painted  using  a  system  per 
applicable specifications in  Section 24.4 of Chapter 24, Painting, with an approved quality 
primer and enamel paint, black in colour, or as otherwise shown on the Contract plans. 

Motorised gates shall be remote-controlled and horizontally sliding. Systems shall be suitable 
to be operated under a local power supply system 220/415 V, 50 Hz. Assembly shall consist 
of photo-electric cells and the pressure switches connected together in series with contacts 
normally closed for remote operation. Assembly shall include the following:  

i.  Heavy gauge steel frame for pad mounting.

ii.  All-weather hinged covers with provision for padlocking

iii.  Adjustable safety friction clutch.

iv.  Adjustable limit switches, rotary type

v.  Magnetic solenoid locking brake

vi.  Emergency disconnect for manual operation in case of power failure

vii.  Magnetic  reversing  starter,  of  size  1  contactor  type,  with  overload  and  under  voltage

protection. 

viii.  Factory prewired electrical system

ix.  Permanent lubricated heavy-duty bearings and heavy-duty roller chain

x.  Removable hood for the motor.

xi.  Operator shall be suitable to withstand the local weather conditions IP54.

xii.  Motor  shall  meet  the  international  standards,  IEC,  and  shall  be  suitable  for  remote

operation 

xiii.  Electric gate operator shall include electric gate operator to be located as indicated on

the Contract plans. Operator shall have parallel 3-button illuminated control stations for 
open,  stop,  and  close.  Electrical  conduit,  switches,  wiring,  and  connections  specified 
under the applicable electrical sections shall be provided 

xiv.  Pedestrian gates shall be of manually operated type

xv.  Padlock with 3-sets of master keyed keys for each gate.

2.  Stop Bar

Stop  bars,  or  traffic  barriers,  shall  be  designed  for  a  100  %  duty  cycle.  Barriers  shall  be 
equipped with a torque motor that lifts the boom arm through a sinusoidal level system that 
allows  the  boom  arm  to  be  locked  in  both  the  up  and  down  positions.  All  the  electronic 
equipment shall be manufactured to ISO 9002 standards. Boom arms shall lift up to at least 
85°  in  the  event  of  power  failure.  At  least  4  tension  springs  shall  be  available  for  counter 
balancing.  Left-  and  right-hand  barriers  shall  be  provided,  as  required,  with  round  or 
octagonal boom arms. Barriers shall be design to require minimum maintenance. 

Boom arms shall be available to at least 6 m long and made from extruded aluminium tubing 
powder-coated  in  white  with  red  reflective  tape.  Boom  arms  shall  be  joined  to  the  boom 
adapter so that the attachment will sheer in case of accidental collision and prevent damage 
to the barrier and boom arm. Jack knife kits shall be provided, if required, for height restricted 
areas for up to 4.5 m boom arms. 

Left- and right-hand boom arm configurations shall be available. Rubber buffers shall be used 
for dampening on the down position to eliminate bouncing. A minimum 60 w, 220 v AC, 50 
hz motor gear box shall be provided, and shall include 100 % duty cycles. An instant reverse 
torque drive motor with a minimum design operating temperature of 50° C shall be provided. 
Booms shall open to 90° under power and at least 85° on power failure. 

Cabinets shall be an IP54 enclosure, manufactured from a minimum 1.6-mm 3CR12 stainless 
steel.  Cabinets  shall  be  powder-coated  in  any  RAL  colour  selected  by  the  Engineer. 
Operating speeds shall be from 2 seconds to 4 seconds from horizontal to vertical position. 

C

ONSTRUCTION

 

 

Modular  electronics  with  plug-in  attachments  shall  be  used  for  control.  Large,  lockable, 
hinged doors shall be provided for easy access. 

7.7.2.2 

Glare Screens 

Glare screens may be of two types, as shown on the Contract plans and as discussed below.  

a.  Type 1:  Glare screen shall consist of a multipiece vertical blade delineator system used along 

medians.  They are the type positioned on the top of median barriers to create a visual shield 
for  the  length  of the median.  They  can  be  used  for  both  temporary  detours  and  permanent 
medians. Salient features of the Type 1 glare screens shall be as follows: 

1.  Modular,  with  components  consisting  of  a  vertical  blade,  base  and  horizontal  base  rails. 

Vertical blades shall be of sizes as shown on the drawing, but typically are available in 60 
mm through 1000 mm heights. 

2.  Durable manufactured of impact resistant, non-metallic polymeric materials.  All materials 

shall  be  new.  Blade,  base  and  rail  shall  have  sufficient  strength  to  withstand  5  impacts 
beginning with 15 mph and progressing through 25, 35, 45 and 55 mph respectively.  Device 
used for impacting the glare screen shall be a horizontal steel bar with a 400 mm by 60 mm 
plastic  covered  steel  plate  attached  to  simulate  truck  bumpers,  trailers  and  wide  or 
overhanging loads.  Lowest point of impact by the steel plate will be 250 mm above the top 
of the barrier wall.  After 5 impacts all blades shall remain attached to the system, stand 
erect, be serviceable, and exhibit no delaminating or cracking. 

b.  Type  2:    Visual  barrier  fence  which  can  also  be  installed  on  concrete  barriers  and  steel 

guardrails or in standalone installations.  They are typically used for curved roadways, access 
ramps, raised highways and construction lanes.  Glare screen fence types and sizes shall be 
as shown on the Contract plans, but are typically of the general types as follows: 

1.  Style A:  Woven wire panels with approximately a 25 mm diamond wire mesh.   

2.  Style B: Chain-link fencing with vertical wood or plastic material slats. 

3.  Alternate manufactured fence panel type as may be approved by the Engineer.  

All  material  used  in  the  construction  of  the  fence  shall  be  new.  Iron  or  steel  material  shall  be 
galvanised or aluminium-coated, as specified. Imperfectly galvanised or aluminium-coated material, 
or  material  upon  which  serious  abrasions  of  galvanising  or  aluminium  coating  occur,  will  not  be 
acceptable. 

Glare screen fence fabrics for Style A and Style B fences shall consist of diamond-woven wire mesh. 
Fabric wire shall be 3.76 mm iron or steel wire that shall meet all of the requirements of ASTM A392 
galvanised or ASTM A491 for aluminium-coated, except that galvanising of the Style B glare screen 
fabric shall be not less than 305 g/m

2

 and shall be done before weaving. Aluminium coating shall be 

Class II. 

Style A glare screen mesh size shall be approximately a 25 mm diamond. Style B glare screen mesh 
size shall be a maximum of 90 mm vertical and 140 mm horizontal. Design of the Style B shall permit 
the slats to be installed in a vertical position, as shown in the Contract plans without distortion of the 
slats. 

All fencing materials for the Type 2 glare screen fences shall meet the applicable requirements of 
Article 7.7.2.1 for chain-link fencing. Vertical slat materials for the Style B glare screen fence shall 
meet the following requirements: 

1.  Wood slats shall be 10 mm by 60 mm by the height designation of the fence. Material shall be 

finished  and  treated  and  shall  be  free  from  loose  knots,  cracks,  or  other  imperfections.  A 
dimensional tolerance of ±1.5 mm in width or thickness is allowed provided that the maximum 
space between slats does not exceed 19 mm. 

2.  Plastic slats shall be 10 mm by 60 mm by the height designation of the fence. They shall be 

manufactured from tubular polyethylene colour pigmented material consisting of high-density 

virgin  polyethylene  and  colour  pigments,  designed  to  retard  ultraviolet  penetration.  These 
materials shall have a minimum wall thickness of 0.076 mm, ±0.0076 mm, and shall  remain 
flexible without distortion and without becoming brittle through a temperature range of -57º C 
to +121º C. Tensile strength shall be at least 24,820 kPa and the melt index shall not exceed 
0.25. 

Plastic slats shall be retained in place by means of U-shaped retainer members at the bottom 
and top of the fence. Retainer members shall be of the same material as the slats. Colour for 
plastic slats  will be approved by the Engineer  from  samples submitted by the Contractor  or 
supplier. 

7.7.2.3 

Wire Fence 

Wire fence materials shall conform to the requirements of Article 7.7.2.1. All materials used in the 
construction of the wire fence shall be new. All iron or steel material shall be galvanised. Material 
upon which serious abrasions of galvanising occur will not be accepted. Materials shall be accepted 
based on manufacturer’s certificate of compliance.  

a.  Steel Post for Wire Fence

Round post material shall conform to AASHTO M 181, Type I, Grade 1. 

All  angle  post  material  shall  be  hot-dipped  galvanised  in  accordance  with  the  requirements  of 
AASHTO M 111M, Grade 75. Galvanising shall be 541 ml/m

2

 of surface area. Angle posts used for 

end, corner, gate, and pull posts and braces shall have a minimum weight of 4.6 kg/m. 

Posts  shall be not less than 2 m in length. A tolerance of  -5 % on the weight of  individual posts, 
braces or anchor plates will be permitted. One type of line post shall be used throughout the project. 
Line posts shall be studded, slotted, or properly adapted for attaching either wire or mesh in a manner 
that will not damage the galvanising of posts, wire, or mesh during the fastening. Line posts shall 
have a minimum weight of 2 kg/m and shall be provided with a tapered galvanised steel anchor plate. 
Anchor  plates  shall  be  securely  attached  and  have  a  surface  area  of  500,  ±50  mm

2

,  a  minimum 

weight of 0.3 kg and 541 ml/m

2

 galvanising. Only new steel shall be acceptable. Rerolled or open 

seam material shall not be used. 

When painting is specified, the Contractor shall use an approved anticorrosive coating per applicable 
requirements  of  Section  24.3  of  Chapter  24,  Painting.  After  the  installation  of  painted  posts  and 
braces, the Contractor shall spot-coat damaged areas with the same paint colour using paint with at 
least the same anticorrosive properties as the original paint. Size, weight, and area of posts, braces, 
and anchor plates shall be as shown on the Contract plans. 

b.  Wood Posts and Braces for Wire Fence

Outer  bark  and  all  inner  cambium  bark  shall  be  removed  by  the  Contractor  from  treated  posts; 
however, occasional strips of bark may remain if not more than 13 mm wide or more than 75 mm 
long. Only sound timber that is free from decay, shakes, splits, or other defects that can weaken the 
posts or braces, or otherwise make them structurally unsuitable for the purposes intended, shall be 
used. Knots that are sound, tight, trimmed flush, and not in clusters will be allowed, provided they 
do not exceed one-third of the small diameter or the least dimension of the posts and braces. Spurs 
and splinters shall be removed and the ends cut square. 

All wood posts and braces shall be treated. 

Before use all materials shall be of good quality and approved by the Engineer. Peeler cores shall 
not  be  used  for  round  posts.  Wood  fencing  materials  shall  have  sufficient  sapwood  in  the  outer 
periphery to obtain the specified penetration of preservative. Fencing materials shall  be cut to the 
correct length before pressure treatment.  

Line posts shall be 75-mm, minimum diameter round posts or nominal 75-mm by 75-mm square-
sawed posts. If the posts are to be pointed for driving, they shall be pointed before treatment. Line 

posts shall be at least 2 m in length. Pull posts and brace posts shall be 150-mm-diameter round 
posts or nominal 150-mm by 150-mm material not less than 2 m long. 

End, gate, and corner posts, and posts at an intersecting fence, shall be 150-mm-diameter round 
posts or nominal 150-mm by 150-mm material not less than 2.4 m long. 

Preservatives used to pressure-treat wood fencing materials shall meet the requirements as shown 
on the Contract plans or as approved by the Engineer. Minimum penetration of preservative shall 
consist of the following:  

  For material 125 mm or less: 10 mm penetration and 90 % of sapwood

  For material 125 mm or greater: 13 mm penetration and 90 % of sapwood

Retention of the preservative shall be per Table 7-38. 

Table 7-38: Minimum retention in kilograms per m3 

Preservative 

Sawed Posts 

Round Posts 

Creosote 

160.0 

128.5 

Pentachlorophenol 

8.0 

6.4 

ACA 

6.4 

6.4 

ACZA 

6.4 

6.4 

CCA 

6.4 

6.4 

c.  Brace Wire for Wire Fence

Brace wire shall be 3.76-mm wire galvanised to meet the requirements of AASHTO M 279, Type Z, 
Class 1. 

d.  Staples and Wire Clamps for Wire Fence

Staples used to attach the wire fencing to wood posts shall be 3.76 mm, 38 mm long, galvanised to 
meet the requirements of AASHTO M 279, Type Z, Class 1. Wire clamps used to attach the wire 
fencing to steel posts shall be 3.06 mm wire, galvanised to meet the requirements  of AASHTO M 
279, Type Z, Class 1. 

e.  Barbed Wire Material Requirements

Barbed wire shall be furnished by the Contractor where shown on the Contract plans, as approved 
by the Engineer. Typical installations shall be per ASTM A121, Class 1, consisting of 3 strands of 
2.51-mm gauge wire, twisted with 4-point, 2-mm barbs spaced 125 mm apart, at most. 

f.  Barbless Wire Material Requirements

Barbless  wire  shall  meet  the  same  requirements  as  barbed  wire,  except  that  the  barbs  shall  be 
omitted. 

g.  Wire Mesh Material Requirements

Wire  mesh  shall  conform  to  the  requirements  of  AASHTO  M  279,  Type  Z,  and  shall  consist  of  8 
horizontal wires with vertical stays spaced 300 mm apart. Top and bottom wires shall be 3.43 mm, 
and the intermediate wires and vertical stays shall be 2.51 mm. Mesh shall have a total width of 0.8 
m and a height as shown on the Contract plans.  

Galvanising  shall  be  Class  3.  Zinc-coated  wire,  as  represented  by  the  test  specimens,  shall  be 
capable  of  being  wrapped  in  a  close  helix  at  a  rate  not  exceeding  15  turns  per  minute  around  a 
cylindrical steel mandrel having a diameter the same as the specimen being tested, without cracking 
or  flaking  the  zinc  coating  to  such  an  extent  that  any  zinc  can  be  removed  by  rubbing  with  bare 
fingers. 

h.  Vertical Cinch Stays for Wire Fence

Vertical cinch stays shall be 3.6 mm galvanised wire meeting the requirements of AASHTO M 279, 
Type Z, Class 1. Minimum weights for zinc coating shall be 92 g/m

2

 of uncoated wire surface. Tie 

wires, hog rings, and post clips shall be zinc-coated steel of good commercial quality and shall be of 
the same gauge as the fence fabric being fastened. 

i.  Miscellaneous Hardware for Wire Fence

Galvanised bolts, nuts, washers, braces, straps, and suitable devices for holding barbed wire and 
wire mesh firmly to metal posts shall be used. Bolts, nuts, hinges, latches, and other miscellaneous 
hardware shall be galvanised in accordance with AASHTO M 232M. 

j.  Wire Gates

Gate frames shall be constructed of galvanised pipe with a nominal diameter of not less than 25 mm. 
Pipes shall conform to the requirements of AASHTO M 181 Type I, Grade 1. Wire gates shall be not 
less than 1.2 m in height and shall be designed to fit openings of the widths called for in the Contract 
plans. Each gate shall be provided with 2 upright braces of the same material as the frame, spaced 
at quarter points in the gate. All gates shall be provided with adjustable 8-mm-diameter galvanised 
diagonal truss rods from corner to corner. 

Gate frame shall be provided with wire mesh conforming to the requirements specified in Sub-article 
g, of Article 7.7.2.3, except that it shall consist of 10 horizontal wires and have a total width of 1.2 m. 
Each gate shall be furnished complete with necessary galvanised hinges and latches designed for 
use with the type of gate posts used on the project. Hinges shall be so designed as to be securely 
attached to the gate post and to enable the gate to swing back against the fence. Double gates shall 
be hinged in the same manner as single gates and shall be provided with an approved galvanised 
drop-bar locking device. Galvanising for hinges, latches, and locking devices shall be in accordance 
with AASHTO M 232M. 

Gates greater than 1.5 m wide shall have a vertical member installed at the midway point of the gate. 
Gates  shall  be  hung  by  at  least  2  steel,  ductile  iron,  or  malleable  iron  hinges,  so  designed  as  to 
securely  clamp  to  the  type  of  gate  post  furnished  and  permit  the  gate  to  swing  back  against  the 
fence. Gates  shall  be  provided  with  a  combination  steel,  ductile  iron,  or malleable  iron  catch  and 
locking  attachment  that  will  not  rotate  around  the  latch  post.  Stops  to  hold  gates  open  shall  be 
provided, where required. 

7.7.2.4 

Temporary Fencing 

The  Contractor  shall  furnish,  install,  maintain  and  remove  temporary  fencing  at  existing  utilities, 
services,  along  detour  roads,  as  required  for  safety  of  the  public,  as  specified  herein  and  where 
directed by the Engineer.  

Temporary  fencing  shall  consist  of  wood  fence  posts  a  minimum  of  1.5  m  in  length  and  with  a 
minimum cross-sectional dimension of 75 mm in any direction, set 600 mm into the ground at 3 m 
on centres, and end struts or braces, as required. Steel fence posts may be substituted for wood, if 
approved by the Engineer. 

Two strands of approved, brightly coloured utility type plastic warning tape shall be stapled to the 
wood fence posts at the top and at mid-height in a taut and workmanlike manner.  

7.7.2.5 

Sand Fences 

Sand fences may consist of one of two types, and shall be supplied and constructed as shown on 
the Contract plans, and as described below: 

a.  Wire fences used as camel fences:  Camel fences shall meet the material and construction

requirements of Article 7.7.3.4 as modified by the following items: 

1.  Line wires:    16 nos. line wires,  3.15 mm dia., to every post with tensile strength of 1200

N/mm

2

 and galvanized according to AASHTO M 279, Type Z, Class 1. 

2.  Straining, start, end and corner posts: Metal posts having IPE 120 section, 3000mm long,

hot dip galvanized to  BS EN ISO 1461. Straining posts are installed at maximum 300 m 
centers.  Start, end and corner posts are installed at the locations described in Sub-article 
a, of Article 7.7.3.4.  

3.  Intermediate  (line)  posts:  Metal  posts  having  IPE  80  section,  2900  mm  long  and  Article

7.7.3.4. Intermediate posts are provided at every 7.5 m centers. 

4.  Struts (braces):  Struts for straining and end posts are of IPE 80 sections and are 3000 mm

long, hot dip galvanized to BS EN ISO 1461. 

5.  All post and strut foundations shall be concrete bedded in accordance with Article 7.7.3.2.

6.  Dropper  bars:

   

11  nos.  dropper  bars  per  bay  of  7.5  m  to  keep  the  line  wires  in  place.

Droppers shall have aluminium clips to connect the bars to the line wires. 

b.  Sand control fences used for trapping windblown sand:  Sand control fences shall be supplied

and  constructed  as  shown  on  the  Contract  plans  and  as  approved  by  the  Engineer.    Sand 
control fences shall be a provided from a single manufacturer with the posts, wire and vertical 
slats acting as a single system.  Sand control fence shall be comprised of support posts, wire, 
wood slats woven into the wire tension strands, fittings, braces, and all necessary hardware. 
Approved sand control fences shall meet the following requirements: 

1.  Overall above ground height of the fence shall be approximately 2 m.

2.  Porosity of the fence system (open space between the vertical slats) to be within 40 to 60

% of the frontal fence area. 

3.  Slats composed of durable wood, treated against insects, with sizes approximately 1.8 m

by 40 mm by 10 mm.  Slats shall be evenly spaced and fixed into the wires by twisting each 
tension  wire  pair  around  each  slate  and  fixed  with  a  galvanized  steel staple.    Each  twist 
shall be not less than two 360

o

 twists of the wire in the weave between the slats. 

4.  Galvanised steel tension wires galvanized according to AASHTO M 279, Type Z, Class 1,

gauge 12 or larger, having minimum tensile strength of 1200 N/mm

2

. Tension wires shall 

consist of a minimum of 4 no., 2-wire pairs spaced evenly over the height of the fence.   

5.  Post shall be carbon steel pipes, hot dip galvanized to BS EN ISO 1461,  50 mm dia. 3 m

long,  placed  3  m  apart,  with  a  4  mm  wall  thickness,  Posts  shall  be  have  suitable  wire 
attachment provisions meeting the requirements of Sub-article a, of Article 7.7.2.3. 

7.7.2.6 

Animal Grid 

The  Contractor  shall  furnish,  place,  and  construct  animal  grids  in  accordance  with  these 
specifications and  requirements of  BS 4008:2006 and conforming to the details, dimensions, and 
locations shown in the Contract plans.  

The Contractor shall provide shop drawings for the Engineer’s approval prior to construction of the 
animal grid. 

Unless otherwise specified, all structural steelwork shall be Grade S275 conforming to BS EN 10025, 
and shall be galvanized in accordance with BS EN ISO 1461:2009. 

Unless otherwise specified, all bolts shall be Grade 4.6 conforming to BS 3692:2001. 

Unless otherwise specified, all welds shall be in accordance with BS EN 1011-1:2009, BS EN 1011-
2:2001, and BS EN 1011-8:2004. 

Concrete and steel reinforcement for use in animal grids shall meet the applicable requirements of 
Chapter 4, Concrete Works, and Chapter 5, Reinforcing Steel, of these standard specifications. 

C

ONSTRUCTION

 

 

7.7.3 Construction Requirements 

7.7.3.1 

General 

Fence  lines  shall  be  cleared  of  all  trees,  brush,  logs,  up-turned  stumps,  roots  of  downed  trees, 
rubbish, and debris. Minor irregularities in the path of the fencing shall be levelled-off.  

Clearing width shall be approximately 3 m, or as shown on the Contract plans or approved by the 
Engineer.  

Grubbing  will  not  be required,  except  where  short  and  abrupt  changes  in  the  ground  contour  will 
necessitate removal of stumps to properly grade the fence line. Any high points that interfere with 
the placing of fence fabric shall be excavated to provide the clearance shown on the Contract plans. 
All stumps within the clearing limits shall be removed or close cut. Grading of the fence line shall be 
sufficient enough to prevent short and abrupt breaks in the ground contour and improve the aesthetic 
appearance of the top of the fencing when installed. It is expected that in the performance of this 
work, machine operations will be required for chain-link fencing, and handwork will be required for 
wire fencing 

— except where sufficient widths exist for machine work. 

Fences  shall  be  constructed  close  to  and  inside  the  ROW  line  unless  otherwise  directed  by  the 
Engineer or shown in the Contract plans. Deviations in alignment to miss obstacles will be permitted 
only when approved by the Engineer and only when such deviations will not be visible to the travelling 
public or adjacent property owners. 

Damaged fences or gates shall be repaired or replaced by the Contractor. If posts cannot be repaired 
by straightening, the Contractor shall remove and replace the post and foundation. When a fence 
installation  is  to  be  removed  in  its  entirety  and  not  replaced,  the  Contractor  shall  return  all 
salvageable  material  to  the  location  shown  in  the  Contract  plans  and  backfill  all  postholes  with 
suitable material.  Salvaged fence  fabric shall  be returned  to the  Owner  in  secured  rolls  not more 
than 15 m long. Unsalvageable materials shall be disposed of by the Contractor. 

7.7.3.2 

Chain-link Fence and Gate Construction 

All gates, corners, and end posts shall be fitted with tops designed to fit securely over the posts. A 
top rail shall be fastened to the side of the gate posts, corners, and end posts; and, on the top of the 
line posts by steel or malleable iron or wrought iron fitting, galvanised, at each connection 

— all in 

accordance with the detail indicated on the Contract plans. All required fittings and hardware shall 
be fastened to the posts in the proper manner. 

Changes in line where the angle of deflection is 15 degrees or more shall be considered corners and 
shall  require  the  installation  of  corner  posts.  Post  spacing  and  placement  shall  conform  to  the 
requirements of Table 7-39.  

Table 7-39: Post spacing and placement for chain-link fence 

Post type 

Required spacing or placement 

Line posts 

3 m maximum interval 

Pull posts 

50 m maximum interval 
At each change in direction exceeding 20

o

 vertically 

Corner posts 

At each horizontal angle point exceeding 15

o

  

At  line  changes  amounting  to  600-mm  tangent  offset  or  more 
between posts 

Post spacing shall be measured from the centre of one post to centre of the next, and shall be parallel 
to the slope of the natural ground. All posts shall be placed in a vertical position. In unusual locations, 
the posts shall be set perpendicular to the ground surface, as approved by the Engineer.  

All posts shall be set in concrete footings that comply with the details shown on the Contract plans 
and crowned at the top to shed water. Concrete footings shall consist of Class C25/20 concrete and 

 

 

 

 

 

 

 