Abu Dhabi, United Arab Emirates. STANDARD CONSTRUCTION SPECIFICATIONS (PART 1 - ROADS, Second Edition 2020) - page 29

 

  Главная      Manuals     Abu Dhabi, United Arab Emirates. STANDARD CONSTRUCTION SPECIFICATIONS (PART 1 - ROADS, Second Edition 2020)

 

Search            copyright infringement  

 

 

 

 

 

 

 

 

 

 

 

Content      ..     27      28      29      30     ..

 

 

 

Abu Dhabi, United Arab Emirates. STANDARD CONSTRUCTION SPECIFICATIONS (PART 1 - ROADS, Second Edition 2020) - page 29

 

 

S

TEEL

 

 

 

AWS   

 

American Welding Society; 

AWS - D1.4/   

American Welding Society - Structural Welding Code 

– Reinforcing Steel; 

 

 

 

D1.4M:2011   

BS 

 

 

British Standards; 

BS EN

  

 

European Standards; 

CRSI   

 

Concrete Reinforcing Steel Institute; 

CRSI’s  

 

Manual of Standard Practice, 2009; 

ICC-ES 

 

International Code Council Evaluation Service; 

IBC 

 

 

International Building Code; 

ISO 

 

 

International Organization for Standardization; 

ISO 9001:2015 

Quality management systems 

– Requirements. 

Table 5-1 and Table 5-2 identify a set of American Association of State Highway and Transportation 
Officials (AASHTO), American Society for Testing and Materials (ASTM), British (BS), and European 
(BS EN) Standards that support the manufacture and use of reinforcement steel. 

Table 5-1: Designations and titles for AASHTO and ASTM standards that apply to 

reinforcing steel works 

AASHTO 

Designation 

ASTM 

Designation 

Title 

AASHTO M 

284M/M 284-09 

ASTM A 775/A 

775M-07b 

Standard  Specification  for  Epoxy-Coated  Reinforcing 
Bars: Materials and Coating Requirements 

AASHTO M 

317M/M 317-03 

(2007) 

ASTM D3963 / 

D3963M - 

01(2007) 

Standard  Specification  for  Fabrication  and  Jobsite 
Handling of Epoxy-Coated Steel Reinforcing Bars 

 

ASTM A82 / 

A82M - 07 

Standard Specification for Steel Wire, Plain, for Concrete 
Reinforcement 

 

ASTM A934 / 

A934M - 07 

Standard  Specification  for  Epoxy-Coated  Prefabricated 
Steel Reinforcing Bars 

 

ASTM A884 / 

A884M - 12 

Standard Specification for Epoxy-Coated Steel Wire and 
Welded Wire Reinforcement 

AASHTO M 

31M/M 31-10 

(2011) 

ASTM A615 / 

A615M - 12 

Standard Specification for Deformed and Plain Carbon-
Steel Bars for Concrete Reinforcement 

 

ASTM A706 / 

A706M - 09b 

Standard  Specification  for  Low-Alloy  Steel  Deformed 
and Plain Bars for Concrete Reinforcement 

AASHTO M 

225M/M 225-09 

ASTM A496 / 

A496M - 07 

Standard  Specification  for  Steel  Wire,  Deformed,  for 
Concrete Reinforcement 

AASHTO M 

55M/M 55-09 

ASTM A185 / 

A185M - 07 

Standard 

Specification 

for 

Steel 

Welded 

Wire 

Reinforcement, Plain, for Concrete 

S

TEEL

 

 

 

AASHTO 

Designation 

ASTM 

Designation 

Title 

AASHTO M 

221M/M 221-09 

ASTM A497 / 

A497M - 07 

Standard 

Specification 

for 

Steel 

Welded 

Wire 

Reinforcement, Deformed, for Concrete 

 

ASTM A955 / 

A955M - 12e1 

Standard  Specification  for  Deformed  and  Plain 
Stainless-Steel Bars for Concrete Reinforcement 

 

ASTM A1035 / 

A1035M - 11 

Standard  Specification  for  Deformed  and  Plain,  Low-
carbon, 

Chromium, 

Steel 

Bars 

for 

Concrete 

Reinforcement 

AASHTO MP 

18M/MP 18-09 

(2010) 

 

Standard  Specification  for  Uncoated,  Corrosion-
Resistant, Deformed and Plain Alloy, Billet-Steel Bars for 
Concrete Reinforcement and Dowels  

 

ASTM A493 - 09 

Standard Specification for Stainless Steel Wire and Wire 
Rods for Cold Heading and Cold Forging 

 

ASTM A580 / 

A580M - 12a 

Standard Specification for Stainless Steel Wire 

AASHTO T 

68M/T68-09 

ASTM E8 / E8M - 

11 

Standard Method of Test for Tension Testing of Metallic 
Materials 

 

ASTM G12 - 07 

Standard Test Method for Nondestructive Measurement 
of Film Thickness of Pipeline Coatings on Steel 

 

ASTM A370 - 12a 

Standard  Test  Methods  and  Definitions  for  Mechanical 
Testing of Steel Products 

Table 5-2: Designations and titles for BS, and BS EN standards that apply to reinforcing 

steel works 

BS Designation 

BS EN 

Designation 

Title 

BS 

4449:2005+A2:20

09 

 

Steel  for  the  reinforcement  of  concrete.  Weldable 
reinforcing  steel.  Bar,  coil  and  decoiled  product. 
Specification  

BS 

6744:2001+A2:20

09 

 

Stainless  steel  bars  for  the  reinforcement  of  and  use  in 
concrete. Requirements and test methods 

 

BS EN 10088-

3:2005 

Stainless  steels.  Technical  delivery  conditions  for  semi-
finished  products,  bars,  rods,  wire,  sections  and  bright 
products of corrosion resisting steels for general purposes 

BS 8666:2005 

 

Scheduling,  dimensioning,  bending  and  cutting  of  steel 
reinforcement for concrete . Specification  

S

TEEL

 

 

 

BS Designation 

BS EN 

Designation 

Title 

 

BS EN 1011-

1:2009 

Welding.  Recommendations  for  welding  of  metallic 
materials. General guidance for arc welding  

 

BS EN 1011-

2:2001 

Welding.  Recommendations  for  welding  of  metallic 
materials. Arc welding of ferritic steels  

5.3 

Materials 

All reinforcing steel and related materials for which the Contract documents do not define specific 
requirements  shall  comply  with  the  requirements  for  applicable  materials  that  are  outlined  in  this 
section.  

5.3.1 

Uncoated Reinforcement 

Uncoated reinforcing steel shall conform to one of the following specifications, as applicable: 

 

Standard Specification for Deformed and Plain Billet-Steel Bars for Concrete Reinforcement 

(AASHTO M 31M/M 31-10 (2011))

 or 

(ASTM A615 / A615M - 12)

Deformed and plain steel 

bars for concrete reinforcement shall be grade 60 (grade 420) unless otherwise specified in 
the Contract documents. 

  Standard  Specification  for  Low-Alloy  Steel  Deformed  and  Plain  Bars  for  Concrete 

Reinforcement (ASTM A706 / A706M - 09b). 

  Standard Specification for Steel Wire, Deformed, for Concrete Reinforcement (AASHTO M 

225M/M 225-09) or (ASTM A496 / A496M - 07). 

  Standard  Specification  for  Steel  Welded  Wire  Reinforcement,  Plain,  for  Concrete  (ASTM 

A185 / A185M - 07) or (AASHTO M 55M/M 55-09). 

  Standard Specification for Steel Wire, Plain, for Concrete Reinforcement (ASTM A82 / A82M 

- 07). 

  Standard  Specification  for  Steel  Welded  Wire  Reinforcement,  Deformed,  for  Concrete 

(AASHTO M 221M/M 221-09) or (ASTM A497 / A497M - 07). 

  Steel for the Reinforcement of Concrete - Weldable Reinforcing Steel - Bar, Coil and Decoiled 

Product - Specification (BS 4449:2005+A2:2009). 

5.3.2 

Coated Reinforcement 

Any  reinforcing  steel  that  is  to  be  epoxy-coated  shall  conform  to  Section  5.3.1, 

Uncoated 

Reinforcement

. When reinforcing bars require epoxy coating, the coating materials, coating process, 

fabrication,  handling,  identification  of  the  bars,  and  repair  of  damaged  coating  that  occurs  during 
fabrication and handling through completion of the shipment to the job site shall conform  with the 
requirements of  AASHTO  M 284M/M 284-09 (ASTM A 775/A 775M-07b) or AASHTO M 317M/M 
317-03 (2007) (ASTM D3963 / D3963M - 01(2007)) or to ASTM A934 / A934M - 07, as specified in 
the Contract documents. 

Epoxy-coated  wire  and  welded  wire  fabric  shall  conform  to  the  Class  A  requirements  outlined  in 
ASTM A884 / A884M - 12. 

When  epoxy  coating  is  specified,  only  fusion  bonded  epoxy-coated  reinforcement  steel  shall  be 
accepted. No other means of epoxy-coating shall be approved 

Epoxy  coated  reinforcing  bars  shall  be  coated  in  a  certified  epoxy  coating  Applicator  plant  in 
accordance with 

Concrete Reinforcing Steel Institute

 (CRSI) requirements, as outlined in

 Voluntary 

Certification  Program  for  Fusion-Bonded  Epoxy  Coating  Applicator  Plants

,  or  an  equivalent 

standard. 

S

TEEL

 

 

 

Coating  material  shall  be  epoxy  resin  powders  as  specified  in  ASTM  A  775/A  775M-07b.  Before 
using epoxy resin powders that do not meet the above requirements, the Contractor shall have them 
tested by an approved independent testing laboratory for acceptance by the Engineer. 

The Contractor shall supply a representative 1.0 kg sample of the coating material from each batch 
of  material.  Such  samples  shall  be  packaged  in  an  airtight  container  and  identified  by  the  batch 
number. 

Patching material, which shall be furnished by the epoxy coating manufacturer, shall be as approved 
by the Engineer, compatible with the coating, and inert in concrete. Such material shall be suitable 
for repairs that the Contractor or the coating Applicator might make to coated reinforcing bars at the 
Project site. 

Reinforcement steel bars that are to be coated shall be clean and free from rust, scale, oil, grease, 
and similar contaminants. The surface of the steel bars shall be cleaned by abrasive blast cleaning. 
The Contractor shall apply the coating to the cleaned surface as soon as possible after cleaning, 
before any visible oxidation to the surface occurs, and not more than eight hours after cleaning. If 
reinforcement steel bars to be coated have surface defects that prohibit proper coating, the Engineer 
shall reject them. 

To apply coating to cleaned steel reinforcing bars, the Contractor shall apply the electrostatic spray 
method and fully cure the bars in accordance with the recommendations of the 

coating material’s 

manufacturer.  

Epoxy coating film shall be cured and/or post cured to a fully cured condition.  The epoxy coating 
Applicator  shall  check  a  representative  portion  of  each  production  lot,  using  the  method  most 
effective for measuring cure, to ensure that the entire production lot of epoxy coating is fully cured. 

Binding wire used for tying epoxy-coated steel reinforcement shall be PVC coated wires. 

5.3.2.1 

Requirements for Coated Bars at Coating Applicator's Plant 

Coated  bars  shall  meet  the  requirements  outlined  in  this  section  before  leaving  the  coating 
A

pplicator’s plant.  

a.  Thickness of Coating  

After curing, the 

coating’s film thickness shall be 0.13 to 0.30 mm inclusive. The Applicator shall take 

at least 15 evenly-spaced measurements along each side of the test bar. No less than 90% of these 
measurements shall be within the specified limits. Thickness measurements below 0.13mm or more 
0.30mm shall be considered cause for rejection of the coated bar. The limits on coating thickness 
do not apply to repaired areas of damaged coating.  

The thickness of the coating film shall be measured in accordance with ASTM G12 - 07, SSPC-PA 
2  (Procedure  for  Determining  Conformance  to  Dry  Coating  Thickness  Requirements)  or  another 
equivalent thickness measuring method.  

The thickness of the coating film shall be measured on the body of the reinforcing bar between the 
deformations or ribs on a straight length of bar. 

b.  Continuity of Coating  

After  curing,  the  coating  shall  be  free  from  holes,  voids,  cracks,  and  damaged  areas  that  are 
discernible  to  the  unaided  eye.  There  shall  not  be  more  than  two  holidays  (pinholes  that  are  not 
discernible to the unaided eye) in any 300 mm of the coated bar, except at the point of manufacturer's 
bar markings, where holidays may be more frequent. For example, a coated bar that is 12 meters 
long shall not have more than 80 holidays, excluding the exceptions at point where the bar has a 
manufacturer’s markings.  

S

TEEL

 

 

 

Patching of holidays is not required unless a bar has more than two holidays per 300 mm. As directed 
by  the  Engineer,  the  Contractor  shall  either  clean  and  recoat  or  replace  bars  with  three  or  more 
holidays per 300 mm.  

To check holidays, the Contractor shall use a 67.5 volt D.C. holiday detector. 

c.  Adhesion of Coating  

For epoxy-coated bars, the Contractor shall evaluate the adhesion and flexibility of the epoxy coating 
on test bars that have been coated with each production lot. The Contractor shall furnish such test 
bars in addition to the bars to meet the Contract and the Project requirements. The Contractor shall 
supply either six meters of test bars or one percent of the total length of all epoxy coated bars for the 
Project, whichever is less. Test bars may be in one length or multiple lengths, as long as there is 
one test bar of each size for each production lot.  

To evaluate the epoxy-coated test bars, the Contractor shall bend them 120 degrees (after rebound) 
around a mandrel of a diameter corresponding to size of bar indicated in Table 5-3. Each bend shall 
be made at a uniform rate and may take as long as 1.5 minutes to complete. The bend test shall be 
conducted  at  room  temperature  (20-30°  C.)  after  the  specimen  has  been  exposed  to  room 
temperature for a sufficient time to ensure that it has reached thermal equilibrium. No cracking or 
disbonding of the epoxy coating shall be visible to the unaided eye on the outside radius of the bent 
bar. 

Table 5-3: Mandrel diameters for evaluation of epoxy-coated test bars 

Bar Diameter (mm) 

Diameter of Mandrel (mm) 

10 

79 

12 

95 

14 

111 

16 

127 

18 

143 

20 

159 

22 

175 

24 

191 

25 

198 

26 

206 

28 

222 

30 

238 

32 

254 

34 

270 

36 

286 

S

TEEL

 

 

 

Bar Diameter (mm) 

Diameter of Mandrel (mm) 

38 

302 

40 

318 

45 

357 

Fractures  or  partial  failures  of  the  steel  reinforcing  bar  do  not  indicate  that  the  coating  failed  to 
adhere. Neither do visible cracking or disbonding that is caused by imperfections in the bar surface. 
In  all  such  cases,  however,  the  Contractor  shall  test  two  additional  samples.  These two  samples 
shall then meet all adhesion test requirements. 

Evidence of cracking or disbonding of the coating shall be considered cause of rejection of the coated 
bars represented by the sample subject to conducting 2 re-tests. 

Before  shipment  from  the  manufacturer’s  plant,  coated  bars  shall  meet  all  of  the  requirements 
outlined in this section. 

5.3.2.2 

Inspection  

The Owner, the Engineer, or the Engineer

’s representative reserve the right to access to the epoxy 

coating  Applicator's  plant  to  witness  epoxy  coating  processes  for  the  Project  work  and  to  obtain 
example test bars for any tests. 

Unless the Project specifies that they do otherwise, the coating Applicator shall conduct all tests at 
their  plant, before shipment,  in such a way  as to avoid unnecessary  interference  with the coating 
operation. 

5.3.2.3 

Rejection  

The  Owner  or  the  Engineer  shall  reject  coated  bars  that  do  not  meet  the  requirements  of  this 
specification. The coating Applicator has an option to either replace bars with defective coating or 
strip the coating from such bars of coating, clean them, and coat them again in accordance with the 
requirements of this specification. 

5.3.2.4 

Certification  

Each  shipment  of  epoxy  coated  reinforcing  steel  shall  have  a  Certificate  of  Compliance  that  has 
been signed by the Applicator of the coating. Such documentation shall certify that the epoxy coated 
reinforcing  bars  were  cleaned,  coated,  and  tested  in  accordance  with  the  requirements  of  these 
specifications and that they conform as appropriate to the requirements of the following standards: 

  Standard  Specification  for  Epoxy-Coated  Reinforcing  Bars:  Handling  Requirements  for 

Fabrication and Job Site (AASHTO M 317M/M 317-03 (2007)) 

  Standard  Specification  for  Fabrication  and  Jobsite  Handling  of  Epoxy-Coated  Steel 

Reinforcing Bars (ASTM D3963 / D3963M - 01(2007)) 

  Standard  Specification  for  Epoxy-Coated  Reinforcing  Bars:  Materials  and  Coating 

Requirements (AASHTO M 284M/M 284-09) 

  Standard Specification for Epoxy-Coated Steel Reinforcing Bars (ASTM A 775/A 775M-07b) 

  Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (ASTM A934 

/ A934M - 07) 

 

Standard Specification for Epoxy-Coated Steel Wire and Welded Wire Reinforcement

 (ASTM 

A884 / A884M - 12), Class A (for epoxy-coated wire or welded wire fabric)  

The Contractor shall retain such test results for seven years and shall make them available to the 
Engineer upon request. 

S

TEEL

 

 

 

Furthermore,  the  Contractor  shall  have  the  coating  Applicator  regularly  and  frequently  visit  the 
Contractor's  steel  storage,  bending  facilities,  handling  facilities,  and  construction  site  to  ensure 
procedural compliance. 

5.3.3 

Stainless Steel Reinforcing Bars 

When specified in the  Contract document, deformed or plain stainless steel reinforcing bars shall 
conform  to  the  requirements 

outlined  in  ASTM’s  Standard  Specification  for  Deformed  and  Plain 

Stainless-Steel Bars for Concrete Reinforcement (ASTM A955 / A955M - 12e1), AISI 316 or 316LN 
(depending  on  bar  diameter)  or  BS  6744:2001+A2:2009  type  316  (S31 or  S33).  The  geometrical 
classification for the bars shall be Type 2. 

Because  of  the  very  long  term  performance  expected  from  the  stainless  steel  reinforcement,  the 
Contractor shall ensure at the time of arrival of the steel on the Project site that it meets all Project 
specification requirements and that all the factors important for long-term performance are checked 
carefully. Damaged or contaminated stainless steel shall not be accepted.  

All  stainless  steel  reinforcement  shall  be  supplied  by  a  mill  approved  by  the  Owner.  In  addition, 
fabrication (cutting, bending, shaping, making spirals) of the steel shall be by a firm approved by the 
Engineer. If the steel has been supplied, or fabricated by a company that is not approved, the steel 
shall not be acceptable for use.  

5.3.3.1 

Binding Wire 

Binding wire used for tying stainless steel reinforcement shall be 16 or 18 gauge (1.6mm or 1.2mm 
diameter) stainless steel wire to ASTM A580 / A580M - 12a or BS EN 10088-3:2005. 

5.3.3.2 

Certificates and Tags 

Stainless  steel  that  arrives  on  the  Project  site  shall  be  tagged,  indicating  the  mill  and  Fabricator, 
stainless steel type and grade, and bar mark number including stainless designation. The steel shall 
be  accompanied  by  a  "mill  certificate"  verifying  that  the  bars  conform  to  these  standard 
specifications, and the Contract documents where applicable, including the stainless steel type and 
name; chemical composition; finish; tensile properties and bend test results. The mill certificate shall 
be checked by the Contractor to make sure it includes all the information required by the Contract 
documents.  

5.3.3.3 

Bar Markings and Appearance 

The bars shall be marked with a symbol that indicates which mill they are from. The marking shall 
match the paper work (e.g. tag, mill certificate). Marks shall be made on the steel when it is rolled 
into  bars,  so  these  markings  are  permanent  and  are  a  part  of  the  bar.  Bars  shall  be  marked 
approximately  every  1  to  1.5  m,  and  the  marks  shall  appear  as  a  raised  area  of  steel  with  a 
recognizable “picture” such as a letter of the alphabet or a shape like an empty box. Each mill shall 
have a special mark that only that mill uses; the Contractor shall supply the Owner or the Engineer 
with this information when they are approved for use.  

If the marking on the bar does not match one of the common markings or markings used by currently-
approved mills, the steel should not go in the Project work unless it can be confirmed in writing that 
the steel is from an approved source. This confirmation shall be from the supplier of the steel, not 
just the Contractor or Fabricator.  

The surface “colour” of stainless steel does not always look exactly the same. The surface shall be 
uniformly silver-grey in colour, but it may be quite bright or it can be dull in appearance, and still be 
of acceptable quality. However, if the steel does not look grey and looks discoloured 

or has a “brown” 

appearance, or has irregularities on the surface, it shall not be acceptable and shall not be included 
in the Project work.  

S

TEEL

 

 

 

5.3.3.4 

Surface Contamination and Mechanical Defects 

Reinforcing stainless steel bars at the time the concrete is placed shall be free of mud, oil and other 
contaminants that adversely affecting bonding strength, and deposits of iron and non-stainless steel. 
Fabrication  of  reinforcing  stainless  steel  bars  shall  be  such  that  the  bar  surfaces  are  not 
contaminated with deposits of iron and non-stainless steels, or damage due to straightening from 
coil.  

The  Contractor  shall  use  the  proper  bending  equipment  not  to  press  the  steel  from  the  bending 
equipment or the environment into the stainless steel surface to avoid rust contamination on the bar. 
If the amount of rust contamination is excessive, or occurs frequently along the length of the bar, the 
reinforcing bar shall be rejected.  

During the pickling process, stainless steel bars could be contaminated due to excessive iron in rinse 
water. Rinse water shall require periodic changing. If surface has dull appearance, the stainless steel 
bar was not left in acid bath for the required minimum length of time, and shall be cause of rejection.  

Stainless steel with excessive contamination by iron particles due to spray of metal particles from 
adjacent black bar cutting operation shall not be acceptable. 

The  selection  of  the  wrong  equipment  for  straightening  can  damage  the  bar  (flattening  the 
deformations, gouging the surface) and reduce the corrosion resistance of the stainless steel; it shall 
be cause of rejection. 

The reinforcing bar shall be rejected if:  

a.  any area of contamination of the stainless steel by iron exceeds 100 mm in length; 
b.  two or more areas of iron contamination greater than 25 mm in length occur along the 

length of the reinforcing bar;  

c.  there are frequent small occurrences of rust contamination along the full length of the 

bar.  

If reinforcing bars have been rejected due to excessive iron contamination, it may be possible for the 
Contractor  to  have  the  bar  treated  to  remove  the  contamination.  This  can  be  accomplished  by 
mechanical cleaning with a (stainless steel) wire brush, by use of a polishing machine or even by 
chemical treatment (pickling) if the contamination is excessive or other approved methods are not 
successful.  

5.3.4 

Low-carbon, Chromium, Steel Reinforcing Bars 

When specified in the Contract documents, deformed, low carbon, chromium, steel reinforcing bars 
shall conform to the requirements 

outlined in ASTM’s Standard Specification for Deformed and Plain, 

Low-carbon, Chromium, Steel Bars for Concrete Reinforcement (ASTM A1035 / A1035M - 11) and 
AASHTO’s  Standard  Specification  for  Uncoated,  Corrosion-Resistant,  Deformed  and  Plain  Alloy, 
Billet-Steel Bars for Concrete Reinforcement and Dowels (AASHTO MP 18M/MP 18-09 (2010)), with 
a  minimum  chromium  composition  by  weight  of  9.2%.    The  steel  reinforcing  bars  shall  have  the 
minimum yield strength, as required by the Contract documents, and as measured by using the 0.2% 
offset test method of ASTM A370 - 12a. 

5.3.4.1 

Acceptance Requirements 

The Manufacturer of deformed low-carbon chromium steel reinforcing bars shall submit to the Owner 
and the Engineer the following documents for review, evaluation, and acceptance or rejection. 

a.  Trade license 
b.  Complete product description and specifications 
c.  Brief description of manufacturing process 
d.  Copy of the quality manual (Controlled copy) 
e.  Description of quality assurance laboratory 
f.  Evaluation report 

S

TEEL

 

 

 

g.  Test reports by independent testing laboratories 
h.  Vicinity map and factory layout 
i.  Valid certification to ISO 9001:2015 (If available) 
j.  List of personnel and their designation 

a.  Evaluation Report 

The Manufacturer shall submit evaluation report issued by the International Code Council Evaluation 
Service  (ICC-ES),  under  the  2012  and  2009  International  Building  Code  (IBC),  recognizing  the 
deformed low-carbon chromium steel reinforcing bars. The basis of recognition shall be IBC Section 
104.11.  

b.  Quality Management System 

The Manufacturer of reinforcing steel bars shall have a Quality Management System that is aligned 
to the requirements of ISO 9001:2015 standard. 

c.  Quality Assurance Laboratory 

The  Manufacturer  of  reinforcing  steel  bars  shall  have  a  quality  assurance  laboratory  to  carry  out 
factory  production  control  testing  to  ensure  that  the  reinforcing  steel  bars  comply  with  the 
requirements of these Standard Specifications. 

As a minimum requirement, the laboratory shall have the following testing equipment: 

  Calipers and other linear measuring test equipments 

  Weighing Scale (with an accuracy of 100 grams) 

  Chemical Analyzer 

  Tensile Test Equipment 

  Bend Test Equipment 

5.3.4.2 

Identification 

Bundled  reinforcing  bars  shall  have  an  attached  tag  identifying  the  Manufacture

r’s  name,  heat 

number and roll number. The tag shall also bear the ICC-ES evaluation report number. Individual 
reinforcing bars shall be identified by a distinguishing set of marks, rolled into the surface of one side 
of  the  bar,  denoting  point  of  origin,  size  designation  and  minimum  yield  strength  designation  in 
accordance with ASTM A1035 / A1035M 

– 11 or AASHTO MP 18M/MP 18-09 (2010). Illustrations 

of the bars highlighting the identifying marks shall be submitted for reproduction in the evaluation 
report.  

5.3.4.3 

Independent Testing Laboratories 

Independent testing laboratories shall comply with the ICC-ES Acceptance Criteria for Test Reports 
(AC85)  and  Section  4.2  of  the  ICC-ES  Rules  of  Procedure  for  Evaluation  Reports,  and  shall  be 
approved by the Owner. The cost of the independent testing shall be borne by the Manufacturer. 

5.3.4.4 

Test Reports 

Test reports shall comply with AC85. In addition, the test reports shall include sampling procedures, 
test specimen preparation, test procedures, and results of all tests. Where indicated, photographs 
shall be included in the report.  

5.3.4.5 

Product Sampling 

Sampling of the reinforcing bars for tests shall comply with Sections 3.1, 3.3 and 3.4 of AC85.   

Three sets of samples per size per grade shall be taken randomly. The first set shall be tested in the 
plant supervised by the Engineer, the second set shall be sent to independent testing laboratory. 
The third set will be kept by the Manufacturer as reference for future use. 

S

TEEL

 

 

 

The test sample(s) for independent test shall be identified and signed in the presence of the Engineer 
and shall be submitted to the approved independent testing laboratory. 

Number of samples for testing shall be at least 10 pieces by one meter length per size per grade. 

5.3.4.6 

Product Evaluation 

Independent test shall only be conducted if the result of the in-plant test shows satisfactory result. If 
the result of the test conducted by the independent testing laboratory shows non- conformance, the 
retest  shall  be  carried  out  on the  reference  sample  kept  by the  Manufacturer  or  on  new  samples 
collected by the Owner/Engineer, on which full testing shall be carried out, if necessary. If the retest 
passed, the initial product assessment is considered conforming to product specification, otherwise 
the product shall be rejected. 

5.3.4.7 

Mechanical Properties 

Testing  for  tensile  and  bending  properties  of  reinforcing  bars  shall  be  in  accordance  with  ASTM 
A1035  /  A1035M 

– 11 or AASHTO MP 18M/MP 18-09 (2010). Each reinforcing bar size shall be 

tested.  

Conditions of acceptance are as set forth in ASTM A1035 / A1035M 

– 11 or AASHTO MP 18M/MP 

18-09 (2010).  

5.3.4.8 

Dimensions 

The  following  dimensions  shall  be  determined  and  reported  by  the  testing  laboratory  for  each 
reinforcing  bar  size:  weight,  kg/m;  diameter,  mm;  cross-sectional  area,  mm

2

;  perimeter,  mm; 

deformation pattern, spacing and height, mm; and finish.  

Deformations shall be determined based on procedures in Section 8 of ASTM A1035 / A1035M 

– 11 

or AASHTO MP 18M/MP 18-09 (2010). 

Conditions of acceptance are as noted in ASTM A1035 / A1035M 

– 11 or AASHTO MP 18M/MP 18-

09 (2010). 

5.3.4.9 

Chemical Composition 

The chemical analysis of a heat shall be determined in accordance with Section 7 of ASTM A1035 / 
A1035M 

– 11 or AASHTO MP 18M/MP 18-09 (2010). 

Conditions of Acceptance are as noted in Section 7 of ASTM A1035 / A1035M 

– 11 or AASHTO MP 

18M/MP 18-09 (2010). 

5.3.4.10 

Quality Control  

a.  The reinforcing bars shall be produced under a quality control program demonstrating 

compliance with ASTM A1035 / A1035M 

– 11 or AASHTO MP 18M/MP 18-09 (2010).  

b.  Mechanical splices shall be produced under a quality control program in accordance 

with ICC-ES Acceptance Criteria (AC133).  

c.  Quality  documentation  complying  with  the  ICC-ES  Acceptance  Criteria  for  Quality 

Documentation (AC10) shall be submitted for each facility manufacturing or labelling 
products that are recognized in the ICC-ES evaluation report.  

d.  A  qualifying  inspection  shall  be  conducted  at  each  manufacturing  facility  in 

accordance with the requirements of the ICC-ES Acceptance Criteria for Inspections 
and Inspection Agencies (AC304).  

e.  An annual inspection shall be conducted at each manufacturing facility in accordance 

with AC304.  

f.  Special inspections for reinforcing bars and mechanical connectors shall comply with 

IBC  Section  1704.4.  The  evaluation  report  shall  describe  the  special 

inspector’s 

duties. 

S

TEEL

 

 

 

5.3.5 

Bar Lists and Bending Diagrams 

When the Contract documents do not include detailed bar lists and bending diagrams, the Contractor 
shall provide such lists and diagrams to the Engineer for review and approval. Fabrication of material 
shall not begin until the Engineer has approved such lists. The Engineer

’s approval of bar lists and 

bending  diagrams,  however,  shall  in  no  way  relieve  the  Contractor  of  responsibility  for  the 
correctness  of  such  lists  and  diagrams.  The  Contractor  shall  bear  any  expenses  incurred  for  the 
revision of material furnished in accordance with such lists and diagrams to make them comply with 
design drawings. 

5.4 

Fabrication 

Fabrication  methods  for  steel  to  be  used  on  the  Project  shall  conform  to  the  standards  and 
specifications outlined in this section. 

5.4.1 

Cutting and Bending 

Bar reinforcement shall be cut and bent to the shapes shown in the Contract documents. Tolerances 
shall be in accordance with the standards of the American Concrete Institute (ACI) Detailing Manual, 
as documented in the details and detailing of concrete reinforcement (ACI 315-99). All bars shall be 
bent cold in accordance with BS 8666:2005 unless otherwise permitted.  

All cutting and bending of reinforcement bars shall be done by competent workmen using equipment 
that  has  been  approved  by  the  Engineer.  Cutting  and  bending  by  the  application  of  heat  is  not 
allowed (flame cutting). Unless shown otherwise on the Contract plans or unless written approval is 
obtained  from  the  Engineer,  fabricators  shall  cut  and  bend  all  reinforcement  bars  in  an  on-site 
fabrication shop. Bars that will be partially embedded in concrete shall not be bent by fabricators in 
the field, except as specified in the Contract documents. 

Unless otherwise provided on the plans or with written authorization from the Engineer, the minimum 
pin diameter (D) around which a bar (with a diameter d) may be bent shall be as follows: 

  D = 6d for 5 to 22 mm bar sizes  

  D = 8d for 24 to 28 mm bar sizes 

If coated reinforcement is specified, bent reinforcement steel bars shall be coated after bending. On-
site cut and bent of epoxy-coated reinforcing bars s

hall not be permitted, it shall be in the fabricator’s 

shop. The Engineer shall reject any steel with visible cracks in the coating on the outside of a bend 
or damage to coating that causes debonding of the coating. Fabricators may shear or saw bars that 
are shorter than 7.6 meters after coating, as long as resulting damage to the coating does not extend 
more than 12 mm back and fabricators patch the cut ends before any visible oxidation appears. The 
Owner and the Engineer do not permit flame cutting. 

Deformed  low-carbon  chromium  steel  reinforcing  bars  shall  be  accurately  fabricated  to  the 
dimensions  shown  in  the  Contract  documents,  within  the  tolerances  shown  in  the  ACI  315-99  or 
CRSI Manual of Standard Practice. Bends shall conform to the dimensions and details in accordance 
with ACI 315-99, ACI SP-66(04) and/or CRSI Manual of Standard Practice, unless otherwise shown 
in the Contract documents. Bars shall be bent cold, and shall not be bent or straightened in a manner 
that  will  injure  the  material.  Heating  of  the  bars  shall  not  be  permitted.  Bar  cutting  shall  be 
accomplished  by  shearing  or  with  a  fluid-cooled  saw,  and  flame  cutting  shall  not  be  permitted. 
Reinforcing bars partially embedded in concrete shall not be field bent. Fabricated bent bars shall 
not be straightened or rebent in the field. 

5.4.2 

Hooks and Bend Dimensions 

Hook dimensions and bend diameters on the inside of each bar shall be as shown in the Contract 
documents. When the Contract documents do not show the dimensions of hooks or the diameter of 
bends,  such  measurements  shall  meet  the  specifications  of  Section  5.4.1  of  these  standard 

S

TEEL

 

 

 

specifications,  Section  5.10.2  of  the  latest  AASHTO  LRFD  Bridge  Design  Specifications  or  ACI

’s 

Building Code Requirements for Structural Concrete and Commentary (ACI 318-08). 

5.4.3 

Mill Test Reports 

When uncoated steel reinforcing bars are to be spliced by welding or when otherwise requested, the 
Contractor shall provide a certified copy of the mill test report showing physical and chemical analysis 
for  each  heat  or  lot  of  reinforcing  bars  to  the  Engineer.  Bars  that  conform  to 

ASTM’s  Standard 

Specification for Low-Alloy Steel Deformed and Plain Bars for Concrete Reinforcement (ASTM A706 
/ A706M - 09b) are exempt from this requirement. However, welding of steel reinforcement shall be 
upon a specific approval of the Engineer. 

For deformed low-carbon chromium steel reinforcing bars, a certified copy of a mill certification report 
showing physical and chemical analysis for each heat of reinforcing bars shall be provided to the 
Engineer upon request. 

5.4.4 

Identification 

The Contractor shall ship reinforcement bars in standard bundles, after tagging and marking the bars 
in  accordance  with  Concrete  Reinforcing  Steel  Institute  (CRSI)  requirements,  as  outlined  in  their 
Manual of Standard Practice. 

If the coating Applicator is also the Supplier of the reinforced bars, each lot of bars delivered to the 
Project  site shall have both a tag for  the coating Applicator  and the original tag of the reinforcing 
bars’ manufacturer or fabricator. 

5.5 

Application Methods 

5.5.1 

Handling and Storing Reinforcement Steel 

5.5.1.1 

Handling Uncoated Bars 

Uncoated reinforcement steel shall be stored above the ground on platforms, skids, or other supports 
and shall be protected from  conditions that can cause mechanical damage, surface deterioration, 
and  rust. When placed into a construction work, reinforcement  steel shall be free from dirt, loose 
rust,  loose  scale,  mortar,  paint,  grease,  oil,  and  any  non-metallic  coatings  that  can  reduce  bond. 
Reinforcement steel shall be free from defects such as cracks and laminations.  The Engineer will 
not reject reinforcement steel with discoloration as long as the minimum dimensions, cross-sectional 
area, and tensile properties of a hand wire-brushed specimen meet the physical requirements for 
the specified size and grade of steel. 

5.5.1.2 

Handling Epoxy-coated Bars 

Epoxy-coated reinforcing steel shall be handled and stored by methods that shall not damage the 
epoxy coating. All systems for handling epoxy-coated reinforcement shall have adequately padded 
contact areas. All bundling bands shall be padded and all bundles shall be lifted with a strong back, 
multiple supports, or Platform Bridge so as to prevent bar-to-bar or wire-to-wire abrasion from sags 
in the bundles. Bars or bundles shall not be dropped or dragged. Epoxy-coated reinforcing steel shall 
be transported and stored on wooden or padded supports. 

The  Contractor  shall  immediately  cover  bundled  epoxy-coated  reinforcing  steel  with  dense  black 
plastic or other suitable lightproof material to protect the steel from sunlight, salt spray, and weather 
exposure.  The  Contractor  shall  ensure  that  air  can  circulate  sufficiently  around  the  protected 
reinforcement to minimize condensation under the protective covering. 

Bars  shall not be dragged out from the bundles. Rather,  the Contractor shall  lift bars vertically to 
avoid damaging the coating on deformations. The Contractor shall ensure that each bar is properly 
supported as it is fed into the cutting or bending machine. An ideal method to provide this support 

S

TEEL

 

 

 

involves threading a PVC pipe onto a rebar frame to function as a soft roller. The Contractor shall 
handle bars carefully at all times to avoid dropping or otherwise damaging them with tools, heavy 
footwear, or wheelbarrows.  

5.5.2 

Placing and Fastening Reinforcement Steel 

The Contractor shall accurately place reinforcement steel shall as shown in the Contract documents, 
firmly holding bars in position during the placement and consolidation of concrete. Bars shall be tied 
at all intersections around the perimeter of each mat and elsewhere at centres of no less than 600 
mm or at every intersection, whichever is greater. Bundled bars shall be tied together at centres of 
no more than 1.8 meters. Tie wire and metals clips used to fasten epoxy-coated reinforcement bars 
shall be PVC coated wires. If uncoated welded wire fabric is shipped in rolls, the Contractor shall 
straighten it into flat sheets before placing it. Unless the Engineer provides written approval for such 
activity, the Contractor shall not weld crossing bars (a technique called tack welding) to assemble 
reinforcement. 

All chairs and other devices used in supporting, securing, or fastening epoxy coated reinforcement 
steel shall be made of or coated with a dielectric material. The specific hardware that the Contractor 
proposes shall be approved by the Engineer. 

5.5.2.1 

Support Systems for Reinforcing Steel 

The Contractor shall use precast concrete blocks, wire bar supports, supplementary bars, or other 
approved devices to support reinforcing steel bars in their proper positions. Such reinforcing supports 
or devices shall be of such height and placed at sufficiently frequent intervals to maintain the distance 
between the reinforcing steel and the formed surface or the top surface of deck slabs within 6 mm 
of that indicated in the Contract documents. 

Platforms that support workers and equipment during concrete placement shall be supported directly 
on the forms and not on the reinforcing steel. 

5.5.2.2 

Precast Concrete Blocks 

Precast concrete blocks shall have a compressive strength not less than that of the concrete in which 
they are to be embedded. Block faces that contact forms for exposed surfaces shall not exceed 50 
mm × 50 mm and shall have a colour and texture that matches the concrete surface. When used on 
vertical or sloping surfaces, each such block shall have an embedded wire to secure the block to the 
reinforcing steel. Such concrete blocks, when used in slabs, shall have a tie wire, unless the weight 
of the reinforcement is sufficient to firmly hold the blocks in place, in which a groove in the top of the 
block is sufficient. For epoxy-coated bars, such tie wires shall be PVC coated wires. 

5.5.2.3 

Wire Bar Supports 

Wire bar supports, such as ferrous metal chairs and bolsters, shall conform to industry practice as 
described in the 

CRSI’s Manual of Standard Practice. Such chairs or bolsters which bear against the 

forms for exposed surfaces shall be either Class 1-Maximum Protection (Plastic Protected) or Class 
2, Type B-Moderate Protection (Stainless Steel Tipped) for which the stainless steel is type 430 as 
defined in ASTM’s Standard Specification for Stainless Steel Wire and Wire Rods for Cold Heading 
and  Cold  Forging  (ASTM  A493  -  09).  All  wire  bar  supports  and  bar  clips  for  epoxy-coated 
reinforcement shall be PVC coated wires. 

5.5.2.4 

Adjustments 

The  Contractor  shall  adjust  or  relocate  all  non-prestressed  reinforcement  bars  that  support  post-
tensioned concrete during the installation of prestressing ducts or tendons, as required to provide 
planned  clearances  for  the  prestressing  tendons,  anchorages,  and  stressing  equipment  and  as 
approved by the Engineer. 

S

TEEL

 

 

 

5.5.2.5 

Repairing Damaged Epoxy Coating 

All reinforcing bars that require epoxy coating shall comply with the specifications in Section 5.3.2, 
Coated Reinforcement. In addition, the Contractor shall repair all damaged coating on epoxy-coated 
reinforcing steel that occurs during shipment, handling, and placement. If damage to any 300 mm 
segment of rebar exceeds one percent of that total area, the Contractor shall remove and replace 
that bar with an appropriate and acceptably undamaged epoxy-coated replacement bar. Therefore, 
the Contractor shall only repair bars with damaged areas that do not exceed more than one percent 
of any 300 mm segment. This restriction to bar repair does not include sheared or cut ends that are 
coated with patching material. Repairs to any single rebar throughout all of the P

roject’s work stages 

shall not exceed five percent of the total surface area of any bar; no single bar shall have patching 
material  on  a  greater  area  than  five  percent  of  its  total  surface.  Patching  material  shall  be  pre-
qualified as required for the coating material and shall be either identified on the container as meeting 
the following requirements: 

  Annex  A1  of  the  Standard  Specification  for  Fabrication  and  Jobsite  Handling  of  Epoxy-

Coated Steel Reinforcing Bars (AASHTO M 317M/M 317-03 (2007))  

  Annex  A1  of  the  Standard  Specification  for  Fabrication  and  Jobsite  Handling  of  Epoxy-

Coated Steel Reinforcing Bars (ASTM D3963 / D3963M - 01(2007))  

  Standard  Specification  for  Epoxy-Coated  Reinforcing  Bars:  Materials  and  Coating 

Requirements (AASHTO M 284M/M 284-09) 

  Standard Specification for Epoxy-Coated Steel Reinforcing Bars (ASTM A 775/A 775M-07b) 

  Annex  A1  of  the  Standard  Specification for  Epoxy-Coated  Prefabricated Steel  Reinforcing 

Bars (ASTM A934 / A934M - 07)  

When  submitting  patching  material  to  the  Engineer  for  pre-qualification,  the  Contractor  shall  also 
provide  a  Certificate  of  Compliance  that  certifies  that  the  material  meets  the  requirements  of  the 
appropriate standards. The Contractor shall patch damaged areas of rebar in accordance with the 
patching material manufacturer's recommendations. The Contractor shall also allow all patches to 
cure fully before placing concrete over the coated bars. 

Before the Contractor lowers reinforcement steel bars into place and places concrete, the Engineer 
shall inspect coated bars for damage to their epoxy coating. Using the specified patching and repair 
materials, the Contractor shall repair any bars with sheared ends, scars, or minor defects. 

If the bent portion of a fabricated bar has only hairline cracking and its coating has no discernible 
loss  of  bond  (loss  of  adhesion),  repairs  are  not  mandatory.  When  the  bent  portion  of  a  bar  has 
disbondment, however, the Contractor shall remove the disbonded coating, clean the affected areas, 
and repair the bar with patching material. 

In  addition to  meeting  the  requirements  outlined above, the  Contractor  shall,  as  approved  by the 
Engineer, suitably wrap and protect any partially embedded bars that will be left temporarily exposed 
to prevent mechanical or environmental damage to the 

bars’ coating before they are fully embedded 

in concrete. Dowels shall project a minimum of 40 bar diameter unless otherwise indicated in the 
Contract plans. 

5.5.3 

Minimum Test Procurement 

The Contractor shall take one sample of every 100 tons or a fracture of 100 tons of reinforcing bars 
of each size and test them for the following properties:  

  Tensile strength  

  Yield point  

  Elongation after fracture  

  Behaviour in the bend test  

  Behaviour in the re-bend test  

  Deviation from cross section  

  Bond test  

S

TEEL

 

 

 

  Chemical composition  

  Thickness of coating  

  Continuity of coating  

  Adhesion of coating 

Testing  shall 

comply  with  the  requirements  outlined  in  AASHTO’s 

Standard  Method  of  Test  for 

Tension Testing of Metallic Material

s (AASHTO T 68M/T68-09

) or ASTM’s 

Standard Test Methods 

for Tension Testing of Metallic Materials

 (ASTM E8 / E8M - 11). For bars with areas that vary from 

the nominal bar area by six percent or more, testers shall use the measured bar area to calculate 
unit stress. 

All the testing shall be performed at no cost to the Owner and is solely borne by the Contractor. 

If a reinforcing steel sample under test fails to meet the specification requirements at any time, if the 
Engineer considers that the samples presented for test are not truly representative, or if reinforcing 
steel that was not approved have been used on the Project works, the Engineer may instruct the 
Contractor to break out and completely remove all such constructed sections that may include such 
suspect reinforcement steel. 

5.5.4 

Splicing of Bars 

The Contractor shall furnish all reinforcement bars in their full lengths, as specified in the Contract 
documents,  unless  otherwise  permitted.  Except  for  splices  that  are  specified  in  the  Contract 
documents and splices for bars with diameters of 16 mm diameter or smaller, the Contractor shall 
not splice bars without written approval from the Engineer. When the Engineer permits splices, the 
Contractor shall stagger them as far as possible. 

5.5.4.1 

Lap Splices 

Lap splices shall be of the lengths specified in the Contract documents. If the Contract documents 
do not specify lap splice lengths, the Contractor shall adhere to Sections 5.11.5.3.1 and 5.11.5.5.1 
of the AASHTO LRFD Bridge Design Specifications or approved directions from the Engineer. 

In  lap  splices,  the  Contractor  shall  place  and  tie  bars  in  a  manner  that  maintains  the  minimum 
distance from the surface of the concrete, as specified in the Contract documents. The Contractor 
shall not use lap splices for bars with diameters from 40 mm to 50 mm, except as provided in either 
Section 5.11.5.2.1 or Section 5.11.5.5.1 of the 

AASHTO LRFD Bridge Design Specifications

Lap splices for coated bars shall match those for uncoated bars except that tension lap lengths for 
coated bars shall be 50% longer than those for uncoated bars or as required by the 

AASHTO LRFD 

Bridge Design Specifications

5.5.4.2 

Welded Splices 

The Contractor shall only use welded splices for reinforcing bars if the Contract details such work or 
if the Engineer provides written authorization. Welding shall conform to the Contract documents and 
American Welding Society (AWS) specifications as outlined in Section 1.4 of the Structural Welding 
Code - Reinforcing Steel (AWS - D1.4/D1.4M:2011) or BS EN 1011-1:2009 and BS EN 1011-2:2001. 
Only approved welders shall be employed. Tensile testing is required for all welded splices and must 
be  performed  in  accordance  with 

ASTM’s Standard Test Methods and Definitions for Mechanical 

Testing  of  Steel  Products  (ASTM  A370  -  12a)  and  California  Test  670  (Method  of  Tests  for 
Mechanical and Welded Reinforcing Steel Splices). 

The Contractor shall not use welded splices on epoxy-coated reinforcing bars. To avoid heating their 
coating, the Contractor shall not perform welding in close proximity to epoxy-coated bars. 

The Contractor shall not use welded splices on all stainless steel reinforcing bars because welding 
may detrimentally affect the physical characteristics of the material. 

S

TEEL

 

 

 

The  Contractor  shall  not  use  welded  splices  for  deformed  low-carbon  chromium  steel  reinforcing 
bars  that  conform  to 

ASTM’s 

Standard  Specification  for  Deformed  and  Plain,  Low-carbon, 

Chromium,  Steel  Bars  for  Concrete  Reinforcement  (

ASTM  A1035  /  A1035M  -  11) 

or  AASHTO’s 

Standard  Specification  for  Uncoated,  Corrosion-Resistant,  Deformed  and  Plain  Alloy,  Billet-Steel 
Bars for Concrete Reinforcement and Dowels 

(AASHTO MP 18M/MP 18-09 (2010)). 

5.5.4.3 

Mechanical Splices 

The Contractor shall use mechanical splices only if the Contract documents specify such work or if 
the  Engineer  provides  written  authorization.  Such  mechanical  splices  shall  develop  in  tension  or 
compression, as required, at least one hundred and twenty-five percent (125%) of the specified yield 
strength of the bar being spliced. 

When requested by the Engineer, the Contractor shall remove as many as two field splices out of 
each 100 placed in the work, chosen at random by the Engineer, for testing by the Engineer to verify 
that they have 125% of the yield strength specified for the bars being spliced. Slip test is also required 
for all mechanical splices and must be performed in accordance with California Test 670 (

Method of 

Tests for Mechanical and Welded Reinforcing Steel Splices

). 

Mechanical connectors for deformed low-carbon chromium steel reinforcing bars shall comply with 
Section  12.14.3  of  ACI 318  and  shall  be  either Type  1  or  Type  2  in  compliance  with  the  ICC-ES 

Acceptance Criteria for Mechanical Connector Systems for Steel Reinforcing Bars

 (AC133), except 

the testing shall demonstrate 125% of the full tensile strength and full elongation of the actual tested 
reinforcing bars at failure. Verification of compliance, in the form of test results, shall be provided.  

5.5.4.4 

Splicing of Welded Wire Fabric 

Sheets  of  welded  wire fabric  shall  be  spliced  by  overlapping  each  other sufficiently  to  maintain  a 
uniform strength and shall be securely fastened at the ends and edges. The edge lap shall not be 
less than 50 mm more than the width of a single mesh. 

5.5.5 

Substitutions 

The  Contractor  may  substitute  different  size  reinforcing  bars  only  when  so  authorized  by  the 
Engineer.  Substituted  bars  shall  have  an  area  equivalent  to  the  design  area  or  larger,  and  shall 
comply  with  the  specifications  outlined  in  Section  5.7.3.4  of  the  AASHTO  LRFD  Bridge  Design 
Specifications. 

When substituting bars of different sizes, the total number of substitute bars may also be different. 
In such cases, although the number of bars may differ, the substitute bars must provide the same 
total area per unit spacing. Substitution of millimetre bars for bar sizes not readily available from the 
Contractor's  source  may  be  made  on  the  same  basis.  All  bar  substitutions  shall  be  approved  in 
writing by the Engineer. Table 5-4 shows the minimum size, weight, and area required for reinforcing 
bars, as indicated on the Contract plans. 

5.5.6 

Calculated Weights 

To compute the weight (mass) of reinforcing bars and wire reinforcement, the Contractor shall refer 
to Table 5-4 and Table 5-5. 

Table 5-4: Reinforcing bars - nominal weights and areas 

Bar 

Designation 

Nominal Diameter 

Mm 

Nominal Area 

mm

2

 

Nominal Weight 

 kg/m 

Dia. 6 

28 

0.222 

Dia. 8 

50 

0.395 

 

 

 

 

 

 

 

Content      ..     27      28      29      30     ..